BECT832-SSO  Screwdriver Controller

Operation Manual

DELTA REGIS

Tools Inc.

CAUTION - Please read, understand, and follow all operating and safety instructions in 

this manual before using the BECT832-SSO controller.

This controller is designed for use exclusively with the following Delta Regis Brushless 

Electric Screwdrivers:

CESL810-812, CESL823(F/P/PF), CESL824(F/P/PF), CESL827(P)

Do not attempt to use this controller with any other tools.

If you have any questions or concerns, please contact us at:

Delta Regis Tools, Inc.

6945 LTC Pkwy

Port St. Lucie, FL   34946

USA

Ph +1-772-465-4302

Fx +1-772-465-4368

E-mail: [email protected]

Website: www.deltaregis.com

Doc. BECT832-SSO_Man_r1

Copyright © 2018 Delta Regis Tools, Inc

Summary of Contents for BECT832-SSO

Page 1: ...ively with the following Delta Regis Brushless Electric Screwdrivers CESL810 812 CESL823 F P PF CESL824 F P PF CESL827 P Do not attempt to use this controller with any other tools If you have any questions or concerns please contact us at Delta Regis Tools Inc 6945 LTC Pkwy Port St Lucie FL 34946 USA Ph 1 772 465 4302 Fx 1 772 465 4368 E mail sales deltaregis com Website www deltaregis com Doc BEC...

Page 2: ...maximum current rating an internal fuse will disrupt power Should the controller stop functioning or exhibit abnormal or intermittent operation please discontinue use immediately and send the controller to an authorized service centre for troubleshooting and repair 11 Excessive duty cycle will cause the tool and or controller to overheat If this occurs discontinue use until cooled down and reduce ...

Page 3: ...unt Setting Range rundowns batch 1 99 Time Window Settings Minimum acceptable rundown time 0 00 9 90 seconds 0 01 sec increments Maximum acceptable rundown time 0 0 9 9 seconds 0 1 sec increments Audible Alarm Settings selectable On sounds when Good No Good Batch Complete OF sounds when No Good FF sounds when Batch complete No Good EF sounds when Good Batch Complete Input Connections Remote Start ...

Page 4: ...E RECEPTACLE AND MAIN POWER ON OFF SWITCH SCREWDRIVER CABLE CONNECTOR SCREWDRIVER HI LO SPEED SELECTOR INPUT OUTPUT CONNECTION TERMINAL BLOCK DIP SWITCH FOR SELECTING OPTIONAL FUNCTIONS Page 4 Front Face of Controller Rear Panel of Controller KEYPAD AND INDICATORS FOR PROGRAMMING AND STATUS MONITORING PROGRAM FUNCTION KEY LOCK ...

Page 5: ...ctor switch from HI to LO will toggle between the two available speeds voltages Keypad and Programming Basics Page 5 ON CLEAR KEY Pressing and holding the ON button for 5 seconds will cause the display to go blank In this mode the screwdriver will function at HI LO speed but there will be no other functionality counting slow start etc Pressing ON from this mode will restore the display and added f...

Page 6: ...verse the batch count value will decrement by a count of one based on the assumption that the operator is removing the last installed fastener The batch count can be reset to begin a new batch by pressing the ON CLEAR key END OF BATCH RESET TIME Rt When a rundown batch is completed the controller provides a visual indication count 00 and audible indication depending on audible settings that the ba...

Page 7: ... a value lower than High Time Ht during programming or an error Er will occur Ht value must be Lt SEQUENCE LIST 5 available sequences PressandholdSELECT forabout5seconds until SL displays Releaseto view programmedvalue SEQUENCE U1 U5 select to edit Adjustvalue UP DOWN Pressuntil SC displays Releaseto viewvalue Adjustvalue UP DOWN SCREW BATCH COUNT of screws per batch MIN 00 screws MAX 99 screws Pr...

Page 8: ... is only available if Slow Start Time RC is set to 0 0 slow start off The re hit function can t be used in conjunction with slow start nS Disable Screwdriver on NG If nS is set to y yes the screwdriver will be disabled after a no good NG rundown The operator must confirm by pressing the SELECT key or an external confirm signal must be input through the I O applies to forward cw rotation only rt Au...

Page 9: ...h tt until the operator runs the driver and completes the batch Only one of the two optional alarms can be selected for use Page 9 MAX STANDBYTIME BETWEEN RUNDOWNS Time seconds Range 00 99 Pressuntil dt or tt displays Releaseto viewvalue Adjustvalue UP DOWN MAX TOTAL BATCH TIMEWARNING Time minutes Range 00 99 Adjustvalue UP DOWN n no y yes Togglevalue GATE SWITCH INPUT PREFERRED LOGIC Hi Lo Toggle...

Page 10: ...further details on entering parameters Audible Alarm Settings OK and NG Lights Along with the two digit count display the controller also provides visual and audible indication of rundown OK rundown NG and batch complete The OK green and NG red lamps indicate whether the rundown was GOOD or NO GOOD If the rundown is within the set parameters the OK lamp will light up at the end of the rundown cycl...

Page 11: ...external confirmation that the process can continue see DIP SW3 description OFF ON OFF ON OFF ON OFF ON Page 11 Output Terminals OUTPUT TERMINALS 2 thru 7 Connection pairs 2 3 4 5 and 6 7 are dry relay contact outputs AC DC 40V 250mA max INPUT TERMINALS 8 thru 13 COM 14 Connect an external switch between COM terminal 14 and the input terminal 8 13 Use a separate switch contact for each required in...

Page 12: ... the previous batch Placing SW3 in the ON position will require the operator to press the SELECT button or require an external CONFIRM input at the end of each batch before the controller will reset to run a new batch Upon batch completion the display will flash C3 and the screwdriver will be disabled until the SELECT button is pressed or a CONFIRM signal is input SW 4 Multiple External Switch Inp...

Page 13: ...urther details on speed settings 7 Press SELECT The display shows 0 0 The tool is now ready to run tests Use the screwdriver to rundown the fastener on the application The display will count up time in 0 1 second increments until the cycle completes Once complete the cycle time will show in the display Repeat the rundown as many times as desired 8 Move SW5 to the OFF position The controller will p...

Page 14: ...utch E7 FWD REV Switch Error Controller detected a change in the position of the FWD REV switch while the tool was running FWD REV Button was moved by the operator during rundown switch PCB improperly positioned in tool housing or magnetic switching element has failed E8 Brake Error Controller detected an abnormal brake clutch signal before the tool was started clutch is stuck at the top of the cl...

Page 15: ...t max time value The BECT832 SSO Controller is not user serviceable Any repairs must be performed by a Delta Regis authorized service center Please consult Delta Regis Tools for further information and the location of the nearest authorized service center Repairs to brushless DC screwdrivers must be performed by trained personnel knowledgeable and qualified in the repair of DC electric screwdriver...