background image

UDL 250

Long Distance Reader

Wiring and Installation

Instructions

         V14/05/09

#896108

Summary of Contents for Logident UDL 250

Page 1: ...UDL 250 Long Distance Reader Wiring and Installation Instructions V14 05 09 896108...

Page 2: ...ster electronic GmbH deister electronic GmbH reserves the right to make changes to any and all parts of this documentation without obligation to notify any person or entity of such changes May 2009 IO...

Page 3: ...d Environmental Influences 13 6 4 Radiation Patterns of the Transmitting Antenna 14 6 4 1 Cutting Plane Diagram 14 7 Get Connection Preparations 19 7 1 SNG3 Interface Converter 19 8 Commissioning and...

Page 4: ...hin a reading range up to 4 m The most innovative feature of the UDL 250 is its intelligent antenna concept where the polar ization of the antenna can be adjusted in four different ways circular RHCP...

Page 5: ...polarization circular LHCP or RHCP adjustable or linearly vertical or horizontal adjustable Transponder Protocols ISO18000 6 C EPC Class1 Gen2 Anti Collision Identification of several transponders in...

Page 6: ...nsions in mm 3 1 UDL 250 Housing Side View Figure 3 1 1 UDL 250 Side View 3 2 UDL 250 Housing Front View Figure 3 2 1 UDL 250 Front View 6 896108_wi_en_li_udl 250_pro_v130214_io_sk_fh_bf odt V14 05 09...

Page 7: ...3 3 UDL 250 Housing Rear View Figure 3 3 1 UDL 250 Rear View V14 05 09 896108_wi_en_li_udl 250_pro_v130214_io_sk_fh_bf odt 7 Wiring and Installation UDL 250...

Page 8: ...ram male connector The pin assignment of the male connector is as follows PIN Description 1 Vcc 2 RS485 A 3 GND 4 RS485 B Table 4 1 1 Pin Assignment male connector 8 896108_wi_en_li_udl 250_pro_v13021...

Page 9: ...or 120 is factory built in into all UDL 250 and has to be deactivated if necessary see also chapter 9 1 2 Basic Setup enable 485 termination within the configuration menu Web Config The factory settin...

Page 10: ...stub length because of reflections stubs should be kept as short as possible exceptions allow a length up to 30 cm Cable recommendation twisted pair cable cross section at least 0 22 mm2 AWG 24 diffe...

Page 11: ...n LED blinking successful reading writing of a transponder Red LED constantly on malfunction Beeper beep tone successful reading of a transponder Table 5 2 1 Function LEDs and Beeper factory settings...

Page 12: ...For mounting on walls or ceilings the the ball joint bracket can be mounted directly onto the UDL 250 With the LRM1 the reader can be positioned in many directions Both mounting plates of this device...

Page 13: ...ader can be negatively influenced The following list shows what to pay attention to 1 The reader must have visual contact to the transponder There must not be any walls or other devices between reader...

Page 14: ...am shows a perspective view of the UDL 250 in order to help assigning the following cutting planes to the orientation of the reader within space Figure 6 4 1 1 Orientation of cutting planes of UDL 250...

Page 15: ...cutting plane xz polarization vertical pictured frequency 867 MHz V14 05 09 896108_wi_en_li_udl 250_pro_v130214_io_sk_fh_bf odt 15 Wiring and Installation UDL 250 Figure 6 4 1 2 Radiation pattern 1...

Page 16: ...cutting plane yz polarization vertical pictured frequency 867 MHz 16 896108_wi_en_li_udl 250_pro_v130214_io_sk_fh_bf odt V14 05 09 Wiring and Installation UDL 250 Figure 6 4 1 3 Radiation pattern 2...

Page 17: ...cutting plane xz polarization horizontal pictured frequency 867 MHz V14 05 09 896108_wi_en_li_udl 250_pro_v130214_io_sk_fh_bf odt 17 Wiring and Installation UDL 250 Figure 6 4 1 4 Radiation pattern 3...

Page 18: ...cutting plane yz polarization horizontal pictured frequency 867 MHz 18 896108_wi_en_li_udl 250_pro_v130214_io_sk_fh_bf odt V14 05 09 Wiring and Installation UDL 250 Figure 6 4 1 5 Radiation pattern 4...

Page 19: ...well by the SNG3 in case this is connected to a power supply unit itself For this a special wall power supply is available optional also see chapter 10 Accessories The drivers needed can be found on...

Page 20: ...der RDemo and select rdemo172 exe or the equivalent higher version delivered with your product Please follow the installation instructions After successful installation start RDemo 8 2 Port setting Ge...

Page 21: ...etected please proceed as follows 1 Set baud rate to all 2 Click on button Detect Device s 3 After successful search the UDL 250 will be shown in the list of detected devices 4 Select device from list...

Page 22: ...be viewed within the window Monitor In the standard configuration i e factory settings the device is set in Trigger Mode This means the device waits for a Trigger On command for switching the RF fiel...

Page 23: ...tically close RDemo A few seconds later WebConfig displays the current configuration of the UDL 250 which contains device information about the version as well as basic settings such as read mode RF p...

Page 24: ...ial Port 4 click on Device Search addresses 5 software searches for the reader which is connected to the selected COM Port 6 after successful search the reader found will be indicated 7 current reader...

Page 25: ...ass1 Gen2 transponders refer to the specification of EPCglobal Specification for RFID Air Interface 9 1 1 Summary This menu shows an example summary of a current reader configuration Figure 9 1 1 1 We...

Page 26: ...d by parameter tag timeout anticollision Operating mode in case there is more than one tag in the field single shot Operating mode for reading tag data in case there is only one tag in the field The t...

Page 27: ...Bm 16 mW 13 dBm 20 mW 14 dBm 25 mW 15 dBm 32 mW 16 dBm 40 mW 17 dBm 50 mW 18 dBm 63 mW 19 dBm 79 mW 20 dBm 100 mW 21 dBm 126 mW 22 dBm 158 mW 23 dBm 200 mW 24 dBm 250 mW 25 dBm 316 mW 26 dBm 400 mW 27...

Page 28: ...referably use prior to other channels channel mask This mask defines the channels which may be used by the reader Each activated check box enables the use of the corresponding channel for more details...

Page 29: ...1 7 866 3 MHz 2 00 W 2 8 866 5 MHz 1 9 866 7 MHz 1 10 866 9 MHz 2 00 W 2 11 867 1 MHz 1 12 867 3 MHz 1 13 867 5 MHz 2 00 W 2 14 867 7 MHz 1 15 867 9 MHz 1 Table 9 1 5 1 Table of Frequencies 1 low pow...

Page 30: ...input voltage 100 240 V AC output voltage 12 V DC 1 25 A Friwo plug 6757 000 AC DC Power Supply Rail power supply input voltage 100 260 V AC output voltage 24 V DC 2 5 A 6756 000 SNG3 Smart Network G...

Page 31: ...in compliance with the essential requirements and other relevant provisions of the RTTE Directive 1999 5 EC A full declaration of conformity can be requested at info deister gmbh de Approved for use...

Page 32: ...re 7 1 2 Connection Scheme for UDL 250 with SNG3 19 Figure 8 2 1 RDemo Port setting 20 Figure 8 2 2 RDemo deBus button 21 Figure 8 2 3 RDemo deBus configuration 21 Figure 9 1 RDemo WebConfig Button 23...

Page 33: ...Notes V14 05 09 896108_wi_en_li_udl 250_pro_v130214_io_sk_fh_bf odt 33 Wiring and Installation UDL 250...

Page 34: ...Notes 34 896108_wi_en_li_udl 250_pro_v130214_io_sk_fh_bf odt V14 05 09 Wiring and Installation UDL 250...

Page 35: ...Notes V14 05 09 896108_wi_en_li_udl 250_pro_v130214_io_sk_fh_bf odt 35 Wiring and Installation UDL 250...

Page 36: ...0 45 340 1831 Fax 81 0 45 340 1801 info jp deister com Americas and Caribbean Deister Electronics USA Inc 9303 Grant Avenue Manassas VA 20110 Tel 1 703 368 2739 Fax 1 703 368 9791 info us deister com...