Thank you for purchasing Daikin’s schedule timer. 
For proper usage, read this manual carefully before using this unit. 
This manual will help you with anything you can not understand or should anything go 
wrong with the unit during use. 
Keep this manual handy for the future reference. 

00_CV_3P124623-5C.fm  Page 1  Saturday, July 30, 2005  8:10 PM

Summary of Contents for DST301BA61

Page 1: ...timer For proper usage read this manual carefully before using this unit This manual will help you with anything you can not understand or should anything go wrong with the unit during use Keep this manual handy for the future reference 00_CV_3P124623 5C fm Page 1 Saturday July 30 2005 8 10 PM ...

Page 2: ... 1 1 2 3 6 4 9 7 8 10 11 5 DST301BA61 17 15 14 12 13 18 19 20 16 DST301BA61 1 2 00_CV_3P124623 5C_2 fm Page 1 Wednesday August 3 2005 4 53 PM ...

Page 3: ... 2 1 2 3 4 DST301BA61 7 3 2 1 8 6 4 5 DST301BA61 7 6 2 3 7 1 8 5 4 5 6 DST301BA61 DST301BA61 3 7 5 4 6 00_CV_3P124623 5C_2 fm Page 2 Wednesday August 3 2005 4 53 PM ...

Page 4: ...enance Incomplete improvement repair and main tenance may result in a water leakage elec tric shock and fire Improper installation or attachment of equipment or accessories could result in electric shock short circuit leaks fire or other damage to the equipment Be sure only to use accessories made by Daikin which are specifically designed for use with the equipment and have them installed by a pro...

Page 5: ... cause stabs or other injuries Tear apart and throw away plastic packaging bags so that children will not play with them If children play with a plastic bag which was not torn apart they face the risk of suffocation Do not turn off the power immediately after stopping operation Always wait at least five minutes before turn ing off the power Otherwise water leakage and trouble may occur The applian...

Page 6: ...sory The operation controlled by programmed time can be set for up to eight different patterns timer No 1 8 Each schedule pattern can be also selected n Operation controlled by programmed time Operating time and stopping time can be set to the minute by each day of the week The operating and stopping patterns can also be set in schedule according to the time slot given twice a day in tune with the...

Page 7: ...ay 7 DISPLAY SETTING OF DAYS OF A WEEK Flashes below the day of the week pro grammed 8 DISPLAY MALFUNC TION CODE Displays the contents of malfunction during the stop due to malfunction 9 DISPLAY PRESENT TIME Displays the present day of the week and time 10 DISPLAY PRO GRAMMED TIME OF SYSTEM START Displays the time programmed to start 11 DISPLAY PRO GRAMMED TIME OF SYSTEM OFF Displays the time prog...

Page 8: ...ashes and the clock starts NOTES The clock used is of 12 hour type When you turn power supply on the sys tem may display for about one minute and not start to operate after all the liquid crystal displays appear at a time If the CLOCK ADJUSTING BUTTON is pressed by mistake press it again to return to the original state As the clock does not stop the time indicated by the clock is kept correct In c...

Page 9: ...ot displayed and can not be selected 3 Press the BUTTON FOR SELECTING DAYS OF A WEEK and set the proper day of the week Each time you press it the flash ing display of days of a week shifts to the right 1 Setting programmed time 4 Set the programmed time of system start 1 by using the HOUR MINUTE BUTTON Each time the HOUR MINUTE BUTTON is pressed the display is put forward minute by minute and hou...

Page 10: ...tting contents up to the point where the TIMER ON BUTTON or HOL IDAY SETTING BUTTON or BUTTON FOR COPYING PROGRAM OF PREVI OUS DAY is pressed will only take effect The display PROGRAM START and the display of days of a week disappears The flashing display goes off and the No of programmed time of the present day is displayed Then the operation controlled by timer starts The operation controlled by...

Page 11: ...TON to finalize the cancella tion In the same procedure cancel the programmed time of system off 2 B Cancel the whole 7 Press the BUTTON FOR SELECTING DAYS OF A WEEK and shift to the day of the week to be canceled Then press the HOL IDAY SETTING BUTTON the dis play OFF appears at the top of the particular day of the week The programmed time is canceled If you press the button again the display ret...

Page 12: ...nder operation control may be turned on or off a few minutes behind schedule This shows that the signal is being exchanged and does not indicate any failure Operation control code Two different types of operation control codes can be selected when this kit is used indepen dently when not used in conjunction with the central remote controller unified ON OFF con troller etc Individual In case where ...

Page 13: ...dress failure of schedule timer Fixes The following causes are possible Check each one 1 Do the control rangeaddresses in the central remote control ler overlap 2 Do the control rangeaddresses in the on off con troller overlap 3 Are there 2 or more schedule timers con nected Flash UE Malfunction of transmission between indoor unit and optional controllers for cen tralized control Fixes Inspect all...

Page 14: ...troller set for on at the same time If two timer numbers are set make sure that the settings for holidays and working days do not overlap between the different timer numbers The TIME NO is not displayed The following causes are possible 1 The TIME NO is not displayed when using the schedule timer alone It can be set if using the central remote controller at the same time The display remains even t...

Page 15: ...perature from 15 C to 35 C Timer programming Two pairs of programmed time for both system start and system off can be set in units of minute for each day of the week Power failure compensation time Approximately 48 hours for a single occurrence of power failure clock with No of programmed time Size 120 W 120 H 53 D mm Width Height Depth Weight Approximately 210g 120 16 37 71 120 01_EN_3P124623 5C ...