PURISMA 

                                            U

ser’s Manual 

 

 

 

 

 

 
 

 

DAEYANG MEDICAL CO., LTD. 

 
 
 
 
 
 
 

Doc. No.  DYMPURISMAM 

Rev. No.  0 

Date 

Jul 17, 2017 

Summary of Contents for PURISMA

Page 1: ...PURISMA User s Manual DAEYANG MEDICAL CO LTD Doc No DYMPURISMAM Rev No 0 Date Jul 17 2017 ...

Page 2: ...2 Contents Precautionary Instructions Caution Warning Danger Introduction 3 3 4 5 6 Technical Specification 6 Features of PURISMA Unit Accessories User Interface 7 7 8 9 How to Use 11 Guarantee 14 ...

Page 3: ...and dusty area or the area which is easy to get splashed by water rain Please observe the recommended operation time and method Use it once or twice a day and do not use any other things than the product supplied by the manufacturer Install the product on a level area Please confer with a doctor when you feel abnormal in your body while using the product Please unplug the power cord when you have ...

Page 4: ...discretion of a user Please contact the sales store or customer service center for help to repair it There may be a risk of electrical shock or fire Please contact the customer service center for a check and repair of the product for the following cases There is a damage on a cable or plug and the product doesn t work properly The product was dropped and damaged The product is wet with water Pleas...

Page 5: ...evice should not be used when cancerous lesions are present in the treatment area Other contraindication are patients suspected of carrying serious infectious disease and or disease where it is advisable for general medical purposes to suppress heat or fevers This device should not be used over or near bone growth centers until bone growth is complete This device should not be used over the thorac...

Page 6: ...ight 3 kg Output Parameter Output Frequency Spot 70KHz JET 12KHz Output Modes SPOT JET Output Voltage Program Level Output voltage Remarks SPOT 1 Level 3 00Vrms 30 Non inductive resistance 500Ω 2 Level 3 10Vrms 30 3 Level 3 20Vrms 30 JET 1 Level 3 8Vrms 30 2 Level 3 8Vrms 30 3 Level 3 8Vrms 30 The PURISMA is designed to operate from any 50 60Hz single phase supply 100 240 Vac All information on mo...

Page 7: ...mospheric Pressure 700 to 1060 hPa Features of PURISMA Unit Front View Front View 1 LCD display for control 1 Power Inlet 2 Fuse 2 T3A 3 On Off Switch 4 Connector for SPOT Handpiece 5 Connector for JET Handpiece 6 Connector for Foot Switch 1 1 4 5 3 2 6 ...

Page 8: ...8 Accessories No Pictures of accessories Name 1 SPOT Handpiece 2 JET Handpiece 3 Foot Switch 4 Power Cord ...

Page 9: ...Continuous 4 Pulse Select the pulse 2 Hz 5 Hz 10 Hz 20 Hz 40 Hz 80 Hz 5 SHOTS Displays number of used shots 6 One Shot Select the one shot 0 2 sec 0 4 sec 0 6 sec 0 8 sec 1 0 sec 7 Auto Setting Automatic output at set time interval 0 1 sec 1 0 sec 8 LED LED ON OFF on the SPOT Handpiece 9 READY START One press makes it START and press the button in Handpiece the output will be generated One more pr...

Page 10: ...ut 1 level 2 level 3 level 3 Mode Select the modes Pulse Continuous 4 Pulse Select the pulse 2 Hz 3 Hz 4 Hz 5 Hz 5 READY START One press makes it START and press the button in Handpiece the output will be generated One more press this button READY will be shown again 6 INFINITE In order to get continuous output press the button INFINITE 6 1 2 3 4 5 ...

Page 11: ...ockwise to loosen it and insert the electrode tip into the top To fix the electrode tip turn the top clockwise 2 Turn on the power switch to start 1 Be sure to set the product on a flat even surface If not damage may occur 4 Do not place liquids on or near the product This may result in electrical shock damager or and fire 2 Do not set the product in a damp and dirty area This may result in electr...

Page 12: ...level outputs continuously 8 The output level can be adjusted in 1 3 levels The level raises by 1 level when pushing button and it goes down by 1 lever when pushing the button 9 After the user setting is complete press the button once The button is changed as 10 The user can set Auto LED INFINITE modes 11 When the setup is completed place the handpiece at the target area and then press the shot bu...

Page 13: ...ect sunlight can increase the temperature 2 Storage Temperature 10 40 3 Storage Humidity 5 95 4 Fix the hand piece on the cradle after use 5 Turn off main switch back of device in case of not using long time 6 Store carefully with tilt vibration and shock avoiding humid environment ...

Page 14: ...tion of accessories and subject to normal wear Should your unit develop a fault please return it to the distributor in the country where the unit was purchased Local Distributor DISTRIBUTOR MANUFACTURER DAE YANG MEDICAL CO LTD 147 Donghwakongdan ro Donghwa ri Munmak eup Wonju si Kangwon do KOREA Phone No 82 33 747 4466 Fax No 82 33 747 1133 http www daeyangmed com ...