INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE 

 

 

 

 

ECOTRONIC

 

 

 

 
 

 

ECOPLUS  

 

ECOTRONIC

 

 

 

 

INOXPLUS

 

 
 
 
 

 

 

 

Summary of Contents for LEADER ECOPLUS Series

Page 1: ...INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE ECOTRONIC ECOPLUS ECOTRONIC INOXPLUS ...

Page 2: ......

Page 3: ... multi impller surface pumps 1 2 2 Electronic boosters with external devices to prevent dry running 1 2 3 Boosters with integrated electronics 1 2 4 Boosters with tank for domestic water supplies 2 3 STARTING THE PUMP 2 4 RECOMMENDATIONS 5 5 TROBLESHOOTING 6 6 DISPOSAL 8 7 GUARANTEE 8 ...

Page 4: ...port service in order to avoid all risks Overload protection The pump has a thermal overload safety device In the event of any overheating of the motor this device automatically switches off the pump The cooling time is roughly 15 to 20 minutes then the pump automatically comes on again If the overload cut 0ut is tripped it is essential to identify and deal with the cause of the overheating See Tr...

Page 5: ...p for the first time If the pump is installed above the water level filling must be performed slowly until the water overflows wait a few seconds to make sure that all the air has escaped and top up until the level has stabilised If the pump is installed below the water level below head bleed the air from the pump casing by opening the filler cap The pump will fill with water independently Plug th...

Page 6: ... must not exceed 28 psi The pump will not operate if the tap is over 50 feet above the level of the pump The electronic device is fitted on the delivery side of the pump by connecting the 1 male connector of the device s inlet to the threaded female of the pump s outlet If the pump does not have a 1 female outlet a connector must be used After the electronic device has been fitted connect the conn...

Page 7: ...rolled pumps The pump must never be allowed to run dry The diameter ot the suction and delivery hoses must not be less than the relative inlet or outletof the pump 1 A hose with a greater diameter should ideally be fitted to the suction inlet when the suction height exceeds 12 feet Do not use metal connectors on the pump s threads Connect the suction hose including a foot valve avoiding counterslo...

Page 8: ... not submerged in the water suction valve blocked the maximum suction depth has been exceeded 1 stop the pump unscrew the delivery pipe shake the pump and suction hose to remove any air bubbles Top up with water connect the hose and delivery pipe ensuring it is correctly sealed and start the pump again 2 check that the joints of the suction hose have been performend correctly Make sure that there ...

Page 9: ...his product or its parts must be disposed of in accordance with the laws regarding the environment Use the local public or private refuse collection services 7 GUARANTEE Any material or manufacturing defects will be corrected during the guarantee period established by current law in the country where the product is purchased It is up to the manufacturer to decide whether to repair or replace any f...

Page 10: ...7 DAB PUMPS INC 3226 BENCHMARK DRIVE LADSON SC 29456 USA TEL 1 843 797 5002 FAX 1 843 797 3366 ...