background image

 
 
 

 

 

 

 

Hybrid Inverter 

 

CPS1200EO12LCD 

CPS2200EO24LCD 

 

User’s Manual 

 

 

Summary of Contents for CPS1200EO12LCD

Page 1: ...Hybrid Inverter CPS1200EO12LCD CPS2200EO24LCD User s Manual ...

Page 2: ...2 ...

Page 3: ...ower Requirements of Your Equipment 7 2 4 Hardware Installation Guide 7 3 DEFINITIONS FOR ILLUMINATED LCD INDICATORS 10 4 OPERATION CONFIGURATION 13 Power On Off 13 Function Setup 13 Audible Alarm 13 Function Setup Guide 13 Charger Control 18 Input Voltage Range Selector 18 5 TROUBLESHOOTING 19 6 TECHNICAL SPECIFICATIONS 21 ...

Page 4: ...vent accumulation and concentration of hydrogen gas at the top of the compartment CAUTION A battery can present a risk of electrical shock and high short circuit current When working on batteries remove watches rings or other metal objects Use tools with insulated handles CAUTION Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected CAUTION To avo...

Page 5: ...nverts renewable solar energy from panels into usable AC and store excess power in batteries as backup power during blackout and emergencies The Solar Hybrid Inverter System comes with a small and compact design which helps to simplify the installation process With Green thinking in mind CyberPower is always in the lead in providing the most pioneering energy saving solution Power Inverter Input P...

Page 6: ...on Diagram 1 Multifunction LCD Readout 2 Power On off Switch 3 Function Buttons 4 DC Input Cable Black 5 DC Input Cable Red 6 Input circuit breaker 7 Charger control 8 Input voltage range selector 9 AC outlet 10 AC inlet 11 PV input terminals ...

Page 7: ...e keep the load below 80 of the unit s rated capacity 2 4 Hardware Installation Guide Step 1 Connect the Battery For optimal battery life and reasonable recharging time make sure the batteries capacity no less than 100Ah Use batteries with same brand type and capacity Connect DC input cables of this product to external batteries Red cable to the battery s Positive polarity Black cable to the batte...

Page 8: ...ION In order to switch off the power from PV for the need of maintenance and service please install a circuit breaker between the product and PV module CAUTION To reduce risk of injury use appropriate cables for PV connection The wiring can only be performed by trained personnel Refer to below table for recommended cable size Model PV Charging Current Wire Gauge CPS1200EO12LCD 40A 12AWG CPS2200EO2...

Page 9: ...capacity is achieved To recharge the battery and maintain optimal battery charge simply leave the unit plugged into a wall outlet at all times The battery can be charged whether the unit is turned on or off DO NOT connect Neutral of the Power Distribution Box to a the OUTPUT Neutral of this product or b the INPUT Neutral of connected equipment Otherwise reversed polarity will damage the product an...

Page 10: ...rmation Icon Description Normal Mode Power On The Power Inverter is turned on Standby Mode Power Off The Power Inverter is off while the LCD display remains on Utility Power Utility power source supplies AC power Solar Power Solar power source supplies to load or battery Load Capacity The approximate load capacity of the unit s outlet in 25 increments Battery Capacity The approximate battery capac...

Page 11: ... the outlet is overloaded Mute This icon appears whenever the unit is in silent mode However when there is a problem with the unit the alarm will still beep even in silent mode Setup Mode This icon appears whenever the unit is in Setup Mode Input Output Battery Information It indicates input output and battery information ...

Page 12: ...Mode the Inverter is off and the solar power charges the battery The LCD is on to show battery status Standby Mode both PV and AC In this Mode the Inverter is off and the Utility power bypasses to output and the battery is charged by both AC and PV The LCD is on to show battery status Line Mode1 The Power Inverter is turned on and AC input power is normal It supplies power to the load connected eq...

Page 13: ...Restart Voltage Low Battery Shutdown Voltage LCD Auto Sleep Cycling Display Back to Default and Return to Status Display Short press the SELECT button to view the functions When a function is selected short press the SETUP button to access the function s options Short press SELECT button to view the options When the desired option is selected short press SETUP button to confirm the setting The uni...

Page 14: ... loads as first priority If solar energy is not sufficient to power all connected loads battery energy will supply power to the loads at the same time Utility provides power to the loads only when any one condition happens Solar energy is not available Battery voltage drops to the low level warning voltage or the setting voltage point in program P04 Page 3 Charger Priority 1 Both 2 Utility 3 PV ES...

Page 15: ...r CPS2200 EO24LCD Unit works in PV mode if solar power is not sufficient to supply loads the battery will power loads at the same time When battery voltage drops to the setting voltage point unit will transfer to utility mode Page 5 Setting voltage point transfer to PV mode from utility mode Note This setting voltage cannot be lower than that in P04 program CPS1200EO12L CD FUL 12 0 12 3 12 5 12 8 ...

Page 16: ...battery the Power Inverter will auto restart at the setting battery voltage Page 7 Low Battery Shutdown Voltage CPS1200EOLC D 10 0 10 2 10 4 10 6 10 8 11 0V CPS2200EO24L CD 20 0 20 4 20 8 21 2 21 6 22 0V ESC 10 0V 20 0V for CPS2200 EO24LCD The Power Inverter will shut off if the battery voltage is decreasing to the setting value Page 8 LCD Auto Sleep Off 0 5 1 2 Min ESC 1 Min If Auto Sleep is sele...

Page 17: ...tons are not touched in 0 5 1 minute the LCD will start cycling the Inverter information Page 10 Back to Default ESC Yes ESC Select Yes to restore the factory default settings Page 11 Return to Status Display Press the Setup button to go back to the status display ...

Page 18: ...Range Selector Input voltage range is defined in specification section Output voltage is the same as input voltage in AC mode Narrow 170 280Vac For connected equipment that are sensitive to the fluctuation of voltage range narrow the input voltage range and the output voltage will follow Wide 90 280Vac For connected equipment that are less sensitive to the fluctuation of voltage range set the inpu...

Page 19: ...rvicing of the DC fuse should only be performed by trained personnel For more information on DC fuse replacement contact CyberPower Systems Batteries are discharged Recharge the unit for at least 8 hours The product may require service Contact CyberPower Systems There is no LCD display The product is not turned on Press the power button Batteries are discharged Recharge the unit for at least 8 hou...

Page 20: ...emperature Beep every second A88 PV Voltage High Beep every second A89 PV Current High Beep every second E07 Output Voltage High Constant tone E09 Output Short Constant tone E14 Overload Fault Constant tone E18 Fan Fail Constant tone E13 Over Charge Constant tone E25 Output Voltage Unbalance Constant tone ...

Page 21: ...1 UN 1 UN Transfer Time 8ms Typical Narrow Mode Battery Battery Voltage 12V 24V Charging Current 20A 15A PV Input Solar Charger Maximum Input Power Watt 500W 1000W Nominal PV Input Voltage 12Vdc 24Vdc Optimal Operating Voltage Range 15 18VDC 30 36VDC Maximum PV Input Voltage 40V 55V Charging Current 40A 40A Environmental Operating Temperature C 0 C to 40 C Operating Relative Humidity 0 to 90 non c...

Page 22: ...irements a Total Voc Product s max PV input voltage b Vmp falls within Product s optimal operating voltage range If one PV module cannot meet this requirement connect multiple PV modules in series to increase the total voltage Example for CPS1200EO12LCD After considering Voc of PV module not exceeds 40VDC and Max Vmp within 15 18VDC we can choose PV module with below specification Pmax 85W Max PV ...

Page 23: ...A CAUTION Ensure that Open Circuit Voltage Voc of PV modules not exceeds 40V for CPS1200EO12LCD and 55V for CPS2200EO24LCD or else the product may be damaged If PV voltage or current is out of normal range the unit will stop solar charging and send a warning code For more information visit www cyberpower com All rights reserved Reproduction without permission is prohibited ...

Page 24: ......

Reviews: