Sliding Gate Operator 

 

U

ser’s Manual

 

 
 

 

 
                     
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

WARNING! 

ONLY  QUALIFIED  AND  EXPERIENCED  TECHNICIANS 

SHOULD  ATTEMPT  INSTALLATION  OR  SERVICE  TO 

THIS UNIT, OTHERWISE, SERIOUS PERSONAL INJURY, 

DEATH, OR PROPERTY DAMAGE MAY OCCUR. 

PLEASE  KEEP  THESE  INSTRUCTIONS  FOR  FURTHER 

REFERENCE.

 

Summary of Contents for CSG 600

Page 1: ...Manual WARNING ONLY QUALIFIED AND EXPERIENCED TECHNICIANS SHOULD ATTEMPT INSTALLATION OR SERVICE TO THIS UNIT OTHERWISE SERIOUS PERSONAL INJURY DEATH OR PROPERTY DAMAGE MAY OCCUR PLEASE KEEP THESE INSTRUCTIONS FOR FURTHER REFERENCE ...

Page 2: ...CONTENT 1 Important Safety Information 2 Main Technical Parameters 3 Working Principle and Main Structure 4 Installation and Adjustment 5 Final Check 6 Maintenance ...

Page 3: ... so that a person can access them by reaching through the gate In the event of power failure an emergency release key allows you to operate the gate manually Do not attempt to tune the gate by placing your hand arm or other body part in the path of the gate as serious injury could result Damage to the gate operator motors may also occur by placing a heavy immovable object in the path during the te...

Page 4: ...gaged the worm rotates the worm gear and output gear which pushes the rack attached to the sliding gate thus moving the gate Fig 1 4 Installation and Adjustment The CSG 600 rack driven gate operator operates by forcing a drive rack past a drive gear The entire configuration is shown in Fig 2 The gate operator must be installed on the inside of the gate Gate preparation Be sure the gate is properly...

Page 5: ...or protected so that no damage can result from contact with any rough or sharp part Concrete pad The base unit of the gate operator requires a concrete pad in order to maintain proper stability The concrete pad should be approximately 300mm x 200mm x 200mm deep in order to provide for adequate operation The pad should be 70mm above finish grade Be sure to locate the pad so that it will not interfe...

Page 6: ...ck Manually move the gate to its closing position Place the three threaded pawls in the same package with rack on the rack element Lay the first piece of rack on the gear and weld the first threaded pawl on the gate Move the gate manually checking if the rack is resting on the gear and weld the second and third pawls The space between rack and gear is about 1mm Bring another rack element near to t...

Page 7: ...sh the sliding gate manually to pre determine the position screw the block to the rack and then tighten the gear clutch with the key Moving the gate electrically adjust the block to the proper position until the position of the opening and closing meet the requirement Fig 6 Block Gate Pawl Rack Gear Guide rail Spring limit switch 19 teeth 122mm 24 teeth 132mm ...

Page 8: ...key to open or close gate manually use the release key as follow Remove the cover Fit the supplied key in the hole Turn the key counterclockwise to release the clutch Pull the release lever Open and close the gate manually After power restored close the release lever then use the manual release key to engage the clutch by turning the key clockwise and resume normal operation Fig 8 Release here ...

Page 9: ... position until the gate opened and closed properly at the limited positions The gate operator is installed with a thermal protector the motor is only designed to work for less than 15 minutes If is runs continually for an extended period of time the thermal protector will switch off the motor automatically in case of the temperature is higher than 120 C and switch on the motor when the temperatur...