background image

TESTING AND PROGRAMMING

INFORMATION

No external moving parts

There is no need to open the cover for operation.

Just one fastening screw on front

The cover secures simply with just a single screw at 
the bottom.

Factory setting

The product is programmed with a default lighting/lux 
level for turning on and off.

Different wiring options

The product can be wired up either at the bottom or on 
the back (concealed installation).

Night switch-off (4 hours)

“Mid-Night Switch-Off”, which turns the light off at 
the mid-point of the night based on the length of 
the previous night (from turn-on to last switch-off). 
Over the course of the year, power consumption by 
outdoor lighting will be cut by around 50%. See wiring 
diagram for operation of night switch-off.

RC circuit 

An RC circuit is included on the PCB to increase 
the product’s life and reliability when it is used 
to control contactors, relays, fluorescent lights, 
inductive loads or small LED loads.

Technical data

Voltage:

230 VAC (+/- 10%)

Load:

1-3600 VA

Physical 

dimensions: 

95x73x37 mm (HBD)

Approval: 

CE mark  

(EMC)

Enclosure:

IP-44, White plastic

MSB16 Photocell

Installation and User Instructions

Part No. 1418252 

Verkstedvegen 19, N-7125 Vanvikan

Tel:

 

+47 72 83 16 11 

Email: [email protected]

Thank you for choosing a product from CTM Lyng AS

For more information, visit us at 

www.ctmlyng.no

Test function, independent of lighting level

To test the product following installation, press 
the cover briefly. The outdoor light comes on for 
3 minutes and the (red) LED inside the product comes 
on at the same time. If the photocell is tested when it 
is dark, the outdoor light will go off for 3 minutes and 
the LED will come on.

Programming desired lighting level

Pressing the cover (“fingerprint”) for at least 
3 seconds at the desired level saves the level. 
The red LED inside the product will flash once 
to confirm the setting.

OVERVIEW AND WIRING DIAGRAM

Pressure-sensitive area 

for testing and 
programming

Fastening 

screw (cover)

Rubber nipples

 in front 

and pre-cut recess for 
wiring through baseplate

Option of external switch 
for programming 
lux level and testing

N   L

LOAD

N   L

IN

SW

2

Nigh

t s

wit

ch-o

ff

 on/

o

ff

SW1

For programming 

lux level and test function

LED

Indicates test/

programming mode

ON 

OFF

Reviews: