Summary of Contents for 580.327122

Page 1: ...a m to 5 p m CT CAUTION Before using this product read this manual and follow all its Safety Rules and Operating Instructions Sears Roebuck and Co Hoffman Estates IL 60179 Visit our Craftsman website www sears com craftsman Part No B2476 Draft 4 2 27 2001 Safety Assembly Operation Maintenance Parts Espahol ...

Page 2: ...not apply to a generator set alternator or engine or parts which have been subjected to improper or unauthorized installation or alteration misuse negligence accident overloading over speeding improper maintenance repair or storage so as in SEARS s judgment to adversely affect its performance and reliability NORMAL WEAR As with all mechanical devices engines need periodic parts service and replace...

Page 3: ...devices overheat if electrical output is lost if engine or generator sparks if flame or smoke is observed while unit is running if unit vibrates excessively Never handle any kind of electrical cord or device while standing in water while barefoot or while hands or feet are wet Dangerous electrical shock will result Use a ground fault circuit interrupter in any damp or highly conductive area such a...

Page 4: ...May be used to supply electrical power for the operation of 120 Volt AC 20 Amp single phase 60 Hz electrical lighting appliance tool and motor loads Air Cleaner Filters intake air as it is drawn into the engine Circuit Breakers Each receptacle socket is protected against electrical overload with push to reset circuit breakers Fuel Tank Tank holds 1 U S gallon of unleaded gasoline Gounding Wing Nut...

Page 5: ... of power CAUTION Although each receptacle is rated for 120 Volts at 20 Amps 2 400 watts or 2 4 kW the generator is rated for a total of 2 500 watts Powering loads that exceed the wattage capacity of the generator can damage it or cause serious injuries The total of loads powered through these receptacles should not exceed 20 Amps Check the ratings of all extension cords before you use them Such c...

Page 6: ...l the oil fill cap and tighten securely Add Gasoline WARNING Never fill fuel tank indoors Never fill fuel tank when engine is running or hot Do Not light a cigarette or smoke when filling the fuel tank _ CAUTION Do Not overfill the fuel tank Always leave room for expansion Use regular UNLEADED gasoline with the generator engine Do Not use premium gasoline Do Not mix oil with gasoline Clean area ar...

Page 7: ... cause blindness or other injury _ ARNING Do Not permit smoking open flame sparks or any other source of heat around a battery Do Not use a lighter or other flame for checking battery fluid levels Wear protective goggles rubber apron and rubber gloves when working around a battery Battery electrolyte fluid is an extremely caustic sulfuric acid solution that can cause severe burns Do Not permit flu...

Page 8: ... determining generator load WATTAGE REFERENCE GUIDE Device Running Watts Air Conditioner 12 000 Btu 1700 Air Conditioner 24 000 Btu 3800 Air Conditioner 40 000 Btu 6000 Battery Charger 20 Amp 500 Belt Sander 3 1000 Chain Saw 1200 Circular Saw 6 1 2 800 to 1000 Clothes Dryer Electric 5750 Clothes Dryer Gas 700 Clothes Washer 1150 Coffee Maker 1750 Compressor 1 liP 2000 Compressor 3 4 liP 1800 Compr...

Page 9: ...e To receive full value from the warranty operator must maintain generator as instructed in this manual Some adjustments will need to be made periodically to properly maintain your generator All adjustments in this section should be made at least once each season Follow the requirements in the Maintenance Schedule chart shown above NOTE Once a year you should clean or replace the spark plug and re...

Page 10: ...g Change the spark plug every 100 hours of operation or once each year whichever comes first This will help your engine to start easier and run better Clean the area around the spark plug Remove and inspect the spark plug Replace the spark plug if electrodes are pitted or burned or the porcelain is cracked For replacement use Champion RN4C or equivalent Check electrode gap with wire feeler gauge a...

Page 11: ...system should be emptied before storage of 30 days or longer Follow these instructions Protect Fuel System _ ARNING Drain fuel into approved container outdoors away from open flame Be sure engine is cool Do Not smoke Remove all gasoline from the fuel tank to prevent gum deposits from forming on these parts and causing possible engine malfunction Run engine until engine stops from lack of fuel Chan...

Page 12: ...s service facility 1 Set switch to RUN 2 Clean or replace air cleaner 3 Fill fuel tank 4 Drain gas tank fill with fresh fuel 5 Connect wire to spark plug Engine will not start or starts and runs rough spark plug 6 Bad spark plug 7 Water in gasoline 8 Overprimed or flooded 9 Low oil level 10 Excessively rich fuel mixture 6 Replace spark plug 7 Drain gas tank fill with fresh fuel 8 Wait 5 minutes an...

Page 13: ...13 ...

Page 14: ...BRIDGE RECTIFIER FIELD 11 POWER 22 22 120 VAC 20A BATTERY CHARGER 66 77 15 55 14 ...

Page 15: ...TO SCREW ON PANEL 22 22 120 VAC A 1 20A C B NOTE POSITIVE BRUSH CLOSEST TO BEARING BRUSHES 6 66 15 IOA C B 3 55 13 77 55 15 ...

Page 16: ...CRAFTSMAN 2500 Watt AC Generator 580 327122 Main Unit m Exploded View 900 5O 51 3O 10 44 r_ 17 13 6O 33 63 L 64 16 ...

Page 17: ... SCREW M6 1 0 x 16 Wing GROMMET Rubber CAPSCREW 5 16 24 x 3 4 Hex GROMMET Bearing Carrier NUT M8 Flanged Serrated WASHER M6 1 4 Shake Proof Item PaN Qty 38 22769 1 45 93639 1 47 93728 2 48 B2479 1 49 B2415 1 50 97082 2 51 81895 4 52 97178 2 53 97912 2 54 B98956B 1 55 B98956A 1 56 B98955 1 57 87841 2 58 39253 6 59 52858 6 60 22246 2 61 25391 2 62 49808 2 63 91094 2 64 75402 2 65 99368 2 66 96049 1 ...

Page 18: ...CRAFTSMAN 4 Cycle Engine 143 986003 Engine Exploded View 279 310 307 I 3o5 161 173 900 159 130 135 120 182 185 184 j_ 7 _ 380 238 250A 250 251 18 ...

Page 19: ...nder Head Exhaust Valve Std incl 151 Exhaust Valve 1 32 OS Intake Valve Std incl 151 Intake Valve 1 32 OS Screw 5 16 18x1 1 2 Screw 5 16 18x2 41 64 Resistor Spark Plug RN4C Item 150 151 153 154 155 157 158 159 160 161 161A 173 178 182 184 185 207 223 224 238 239 240 245 250 250A 251 252 253 254 275 277 278 279 280 305 307 308 310 380 416 417 600 900 Part 37039 31673 36649 650913 35624A 650914 3662...

Page 20: ...10 24x 15 16 1 Screw 8 32x27 64 1 Ground Wire 1 Ground Wire 1 Rocker On Off Switch 1 Control Bracket 2 Screw 10 32xl 2 1 Blower Housing 1 Screw 1 4 20x31 64 2 Screw 10 32xl 2 2 Screw 1 4 20x31 64 Item PaN 285 35985B 287 0 290 30705 292 26460 298 650665 300 37002 301 36754 313 34080 325 29443 327 35392 340 37071 341 36644 342 651010 342A 650738 370A 36261 370L 36771 390 590736 400 36720 287 0 327 Q...

Page 21: ...045A 640019 632547 640015 630748 631027 Qty Description 1 Carburetor 1 Throt Shaft Lever Assy 1 Throt Return Spring 1 Dust Seal Washer 1 Dust Seal Throttle 1 Throttle Shutter 1 Shutter Screw 1 Fuel Fitting 1 Throt Crack Screw 1 Tension Spring 1 Idle Restrictor Screw 1 Idle Restrict Screw Cap 1 Float Bowl 1 Float Shaft 1 Float 1 Float Bowl O Ring 1 Inlet Needle Seat Clip 1 Spring Clip 1 Primer Butt...

Page 22: ...aN 590736 590599A 590600 590696 590601 590697 590698 590699 590700 590705 590535 590701 Qty Description 0 Rewind Starter 1 Spring Pin Incl 4 1 Washer 1 Retainer 1 Washer 1 Brake Spring 2 Starter Dog 2 Dog Spring 1 Pulley Rewind Spring Assy 1 Starter Housing Assy 1 Starter Rope 98 x9 64 dia 1 Starter Handle 7__ _5 __2 D 22 ...

Page 23: ...23 ...

Page 24: ...easonable amount of time not to exceed 30 days Warranty Service can be arranged by contacting either a Tecumseh Authorized Service Outlet or by contacting Tecumseh Products Co c o Service Manager Engine and Transmission Group Service Division 900 North Street Grafton WI 53024 1499 Telephone 1 262 377 2700 or see your local telephone yellow pages under Engines Gasoline for the name address and tele...

Page 25: ...ed or replaced by Tecumseh Products Co according to Subsection 4 below Any such emissions related part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty period prior to the first scheduled replacement point for such emissions related part 4 Repair or replacement of any warranted emissions related part under this ECS Warranty shall be performed at ...

Page 26: ...lica a generadores alternadores motores o pares que hayan sido sujetos a instalaciones o modificaciones incorrectas o no autorizadas mal uso negligencia accidente sobrecarga exceso de velocidad mantenimiento reparaciSn o almacenamiento incorrecto que a juicio de SEARS afecte negativamente su funcionamiento y confiabilidad DESGASTE NORMAL Como con todos los dispositivos mecanicos los motores necesi...

Page 27: ...bustible Si el tanque esta demasiado Ileno el combustible podria rebosarse y caer sobre el motor caliente y ocasionar un INCENDIO o una EXPLOSION Nunca almacene el generador con combustible en el tanque donde los vapores de la gasolina puedan entrar en contacto con llamas abiertas chispas o luces de piloto como en hornos calentadores de agua o secadoras de ropa Podrian ocurrir INCENDIOS o EXPLOSIO...

Page 28: ... el motor Interruptor de Marcha Parado Coloque el interruptor en la posici6n Run Marcha antes de usar el arranque de retroces Col6quelo en la posici6n Stop Parado para detener el motor Motor de 6 0 H P Proporciona la potencia necesaria para generar 2 500 vatios de alimentaci6n el6ctrica Perilla del Cebador Usada cuando se esta dando arranque a un motor frio Silenciador del Apagachispas El silencia...

Page 29: ... kW de potencia _ iPRECAUCION A pesar de que cada tomacorriente tiene una capacidad de 120 Voltios a 20 Amperios 2 400 Vatios o 2 4 kV el generador tiene una capacidad total de 2 500 Vatios Las cargas de potencia que excedan la capacidad de vatiaje del generador pueden causar daSos o lesiones severas El total de las cargas que pasan a trav6s de estos tomacorrientes no debera exceder los 20 Amperio...

Page 30: ...or sobre una superficie nivelada y retire la Tapa de Llenado de Aceite y la Varilla de Medici6n Limpie la varilla de medici6n introdQzcala en el orificio de Ilenado de aceite y apri6tela de manera segura retire la Varilla de Medici6n Si el aceite no esta en la marca de FULL LLENO agregue el aceite recomendado Vi6rtalo lentamente No Ilene por encima de la marca FULL LLENO de la varilla de medici6n ...

Page 31: ...l problema de baja presi6n de aceite el motor no arrancara y la luz comenzara a destellar cada vez que intente darle arranque al motor Revise el nivel del aceite y Ilene siguiendo las instrucciones descritas en la pagina 30 Procedimiento de Carga de la Bateria _ iADVERTENClA Las baterias de acumuladores producen gas explosivo cuando son cargadas el cual permanece alrededor de la bateria por un per...

Page 32: ...aje de arranque cuando seleccione los dispositivos el6ctricos que va a conectar a su generador Primero calcule la cantidad de vatios necesarios para dar arranque al motor mas grande Sumele a ese nQmero los vatios de funcionamiento de todas las otras cargas conectadas La Guia de Vatiaje a continuaci6n ha sido suministrada para ayudarle a determinar cuando elementos puede operar su generador al mism...

Page 33: ...o de la garantia el operador debera mantener el generador de la forma descrita en este manual Se deberan Ilevar a cabo algunos ajustes peri6dicamente para mantener correctamente su generador Todos los ajustes de la secci6n Servicio y Ajustes de este manual deberan ser hechos por Io menos una vez en cada estaci6n Cumpla con los requisitos de la tabla Programa de Mantenimiento descrita anteriormente...

Page 34: ...rame de aceite Limpie Reemplace la Bujia Cambie la bujia cada 100 horas de operaci6n o una vez al aSo Io que suceda primero Esto ayudara a su motor a arrancar mas fAcilmente y a funcionar mejor Reemplacela con una bujia champion RN4C o una de tipo equivalente Limpie el Area alrededor de la bujia Retire y revise la bujia Reemplace la bujia si los electrodos estan picados quemados o si la porcelana ...

Page 35: ... de 30 dias o mas Siga estas instrucciones Proteja el Sistema de Combustible _ iADVERTENCIA Drene el combustible dentro de un recipiente adecuado lejos de llamas abiertas yen lugares al aire libre Asegt_rese de que el motor est6 frfo No fume Retire toda la gasolina del tanque de combustible para evitar que se formen depSsitos de goma en estas partes y causen posible mal funcionamiento del motor Ha...

Page 36: ...e aire 3 Llene el tanque de combustible 4 Drene el tanque de gasolina 116nelo con combustible fresco 5 Conecte el alambre a la bujia El motor no arranca o arranca y funciona mal conectado 6 Bujia en mal estado 7 Agua en la gasolina 8 Exceso de cebado 9 Bajo nivel de aceite 6 Reemplace la bujia 7 Drene el tanque de gasolina 116nelo con combustible fresco 8 Espere 5 minutos y haga girar el motor 9 L...

Page 37: ...37 ...

Page 38: ... negarle cubrimiento de garantia si su equipo de servicio c6sped y jardin o cualquier parte ha fallado debido a abuso negligencia mantenimiento incorrecto o modificaciones no aprobadas Usted es responsable de presentar su motor para equipo de servicio c6sped o jardin a un Centro de Servicio Tecumseh autorizado cualquier Proveedor de Servicio Registrado Tecumseh Distribuidor de Servicio Autorizado ...

Page 39: ...del Propietario estar_ garantizada por el periodo de tiempo anterior al primer punto de reemplazo programado para esa parte Si la parte falla antes del primer reemplazo programado la parte ser_ reparada o reemplazada por Tecumseh Products Co de acuerdo a la Subsecci6n 4 descrita mas adelante Cualquier parte relacionada con emisiones reparada o reemplazada bajo la Garantia ECS estar_ garantizada po...

Page 40: ...e ou les pi6ces For the repair or replacement parts you need Call 7 am 7 pm 7 days a week 1 800 366 PART 1 800 366 7278 Para ordenar piezas con entrega a domicilio 1 800 659 7084 For the location of a Sears Parts and Repair Center in your area Call 24 hours a day 7 days a week 1 800 488 1222 For information on purchasing a Sears maintenance Agreement or to inquire about an existing Agreement Call ...