background image

P

LATINUM 

S

ERIES 

7500

 

K

EYPAD

I

NSTALLATION AND 

P

ROGRAMMING 

I

NSTRUCTIONS

Model 7520

(Front)

Model 7530

(Side)

P

ROGRAMMING 

Q

UICK

G

UIDE

Enter Programming Mode

** (master code) **

Example:

** 1234 **

Programming Functions:
Set Relay to M omentary

1 (time in seconds) #

Example:

1 05 # (Sets to 5 secs)

Set Relay to Latch

1 00 #

Add New User

2 (user n umber) #  (user
code) # (user code) #

Example:

2 002 # 22222 # 22222 #

Change Existing User

2 (user n umber) #  (user
code) # (user code) #

Example:

2 002 # 23456 # 23456 #

Change Master Code

2 0 # (new master code) #
(new master code) #

Example:

2 0 # 382436 # 382436 #

Erase a User Code

3 (user code) #

Example:

3 23456 #

Erase All Users

4 (master code) #

Example:

4 382436 #

Note:

New Master Code must be between 4 & 8 digits.

 

Option 4 erases all User Codes, but not the
Master C ode.

A

VAILABLE 

M

ODELS

Model 7510

(Front)

S

PECIFICATIONS

Input Voltage:  

12-24 Volt DC or 12 Volt AC

Power Consumption: 

120mA max @ 24 VDC, 20mA idle

NOTE: 

3A Power Supply is recommended for use with

door strike or magnetic lock

Programmable Relay:

Form C, dry contacts   

      rated at  2A @ 30VDC (inductive load)

Operating Temperature:                                    

-40

o

C to 125

o

C (-40

o

F to 257

o

F)

Available Models w ith Inst alled Dim ensions:

7510:

Single-Gang Style Keypad            
3.20" W  X 5.10" H x 0.75" D

7520:

Mullion Surface-Mount Keypad       

 

1.75" W  X 7.125" H x 1.00" D

7530:

Mullion Mortise-Mount Keypad       

 

1.75" W  X 7.125" H x 0.25" D

User Codes: 

Up to 200 unique codes including  

 

1 master code.  Codes will be between 4 and 8   

 

digi ts in  lengt h.  Cod es are st ored in nonv olat ile 

 

EEPROM memory.

Lockout Feature:

 Keypad will lock out all           

 

funct ions for 30  second s aft er thr ee consec utiv e 

 

invalid codes.

Factor y Defa ult Sett ings:

Master code

1 2 3 4

User code

5 6 7 8 9 0

Relay Time 5 seconds (Momentary)

P

HYSICAL 

D

ESCRIPTIONS

LED Explanation:

Green LED

:

Steady  off = D oor rel ay deac tiva ted

Steady  on = Doo r rela y acti vated

Red LED:

Normal Operation:

i)

Three sec onds o n = Inv alid  code             

 

entered.

ii)

Slow flash = 30 second delay due to        

 

three consecutive invalid codes entered.

Progr amm ing Mo de:

i)

Slow flash = Program standby, ready to   

 

accept new function.

ii)

Fast flash = Program in progress,            

 

awaiting input. 

iii)

Very fast flash = Erasing all user codes.

                 
         

Wire  Connections:

Power

 - Connect either a 12 - 24 volt direct

current (DC) or a 12 volt al ternating current (AC)
power supply to these terminals.  Polarity does not
matter, as the keypad has been designed to work in
both directions.  Power supplies outside this range

may cause permanent damage to the keypad.

Common

 - This terminal is the Common output

of the relay and is used in conjunction with the
N.O. or N.C. Terminals (see below) to control a
door lock.

N.O.

 - This  term inal  is th e Norm ally  Open

outpu t of t he relay .  In a n orm al lo cked st ate,
this terminal is disconnected from the Common
terminal.  In an unlocked state, this terminal is
connected to the Common terminal.

N.C.

 - This  term inal  is th e Norm ally  Closed

outpu t of t he relay .  In a n orm al lo cked st ate,
this terminal is connected to the Common
terminal.   In an unlocked state, this terminal
disconnects from the Common terminal.

Reset Button

 - This button is used to reset the

master code back to its factory default.  Follow
the in stru ctio ns out lined  in the 

Programming

section, under 

Factory Reset Function

.

Reviews: