background image

Description

• Time Delay surface mount fuse capable of replacing

glass tube fuses in certain applications

• Environmentally rugged, complies with EIA-IS-722

Standard

• Solder Immersion Compatible
• Targeted for Consumer Electronics

Agency Information

• UL Recognition Guide & File numbers: JDYX2 & E19180.

• CSA Component Acceptance: 053787 C 000 & Class

No: 1422 30.

Environmental Data

• Life Test: MIL-STD-202, Method 108A, Test Condition D
• Load Humidity: MIL-STD-202, Method 103B
• Moisture Resistance: MIL-STD-202, Method 106E
• Thermal Shock: MIL-STD-202, Method 107D, air-to-air
• Case Resistance: EIA/IS-722
• Resistance to Dissolution of Metallization:

ANSI J-STD-002, Test D

• Mechanical Shock: MIL-STD-202, Method 213B, Test

Condition A

• High Frequency Vibration: MIL-STD-202, Method 204D,

Test Condition D

• Resistance to Solvents: MIL-STD-202, Method 215A

Ordering

• Specify product code and packaging code

Soldering Method

• Wave Immersion: 260°C, 3 sec max.
• Infrared: 260°C, 30 sec max.

2.6

3.0

(0.102)

(0.118)

4.0

(0.157)

8.6

(0.338)

Land Pattern

Dimensions 

mm

(inches)

Brick

Fuses

6125TD Series, Time Delay

ELECTRICAL CHARACTERISTICS

% of Amp Rating

Opening Time

100%

4 Hours Minimum

200%

1 Second Minimum

200%

2-4 Seconds Typical

200%

60 Seconds Maximum

SPECIFICATIONS

Product

Voltage

Interrupting

DC Cold

Typical

Typical

Code

Rating

Rating*

Resistance** (ohms)

Melting

Voltage

AC           DC

125VAC    60VDC

min.

typ.

max.

I

2

t†

Drop‡

6125TD500mA

125V          60V

50A          50A

.3350    .4025    .4700

0.716

245 mV

6125TD750mA

125V          60V

50A          50A

.2000    .2350    .2700

1.07

250 mV

6125TD1A

125V          60V

50A          50A

.1350    .1680    .2000

2.88

256 mV

6125TD1.5A

125V          60V

50A          50A

.0550    .0630    .0700

2.35

125 mV

6125TD2A

125V          60V

50A          50A

.0380    .0480    .0580

9.45

133 mV

6125TD2.5A

125V          60V

50A          50A

.0280    .0350    .0420

16.2

130 mV

6125TD3A

125V          60V

50A          50A

.0225    .0263    .0300

15.3

97 mV

6125TD3.5A

125V          60V

50A          50A

.0170    .0195    .0220

14.5

95 mV

6125TD4A

125V          60V

50A          50A

.0160    .0185    .0210

38.8

106 mV

6125TD5A

125V          60V

50A          50A

.0115    .0133    .0150

34.4

100 mV

6125TD7A

125V          60V

50A          50A

.0073    .0087    .0100

90.2

99 mV

* AC Interrupting Rating (Measured at designated voltage, 100% power factor); DC Interrupting Rating (Measured at designated voltage, time constant of less than 

50 microseconds, battery source)

** DC Cold Resistance (Measured at 10% of rated current)
† Typical Melting I

2

t (Measured with a battery bank at rated DC voltage, 10x-rated current (not to exceed IR), time constant of calibrated circuit less than 50 microseconds)

‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes)
Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at
elevated ambient temperatures.

Summary of Contents for BRICK 6125TD

Page 1: ...duct Voltage Interrupting DC Cold Typical Typical Code Rating Rating Resistance ohms Melting Voltage AC DC 125VAC 60VDC min typ max I2 t Drop 6125TD500mA 125V 60V 50A 50A 3350 4025 4700 0 716 245 mV 6125TD750mA 125V 60V 50A 50A 2000 2350 2700 1 07 250 mV 6125TD1A 125V 60V 50A 50A 1350 1680 2000 2 88 256 mV 6125TD1 5A 125V 60V 50A 50A 0550 0630 0700 2 35 125 mV 6125TD2A 125V 60V 50A 50A 0380 0480 0...

Page 2: ... reserves the right without notice to change design or construction of any products and to discontinue or limit distribution of any products Cooper Electronic Technologies also reserves the right to change or update without notice any technical information contained in this bulletin Once a product has been selected it should be tested by the user in all possible applications OC 2530 Rev M 5 03 Coo...

Page 3: ...nds Typical 250 120 Seconds Maximum 300 10 Seconds Maximum ELECTRICAL AND POWER CROSS SPECIFICATIONS Product Voltage Interrupting DC Cold Typical Maximum Typical Alpha Code Code Rating Rating Resistance ohms Melting Total Voltage Marking AC 250VAC 600VAC min typ max I2 t Clearing Drop 1st Code 2nd Code TCP500mA 250 V 50 A 40 A 0 420 0 530 0 640 1 3 A2 s 100 A2 s 471mV F TCP1 25A 250 V 50 A 60 A 0 ...

Page 4: ...0134 Toll Free 1 888 414 2645 Cooper Bussmann P O Box 14460 St Louis MO 63178 4460 Tel 1 636 394 2877 Fax 1 800 544 2570 Europe Cooper Electronic Technologies Cooper UK Limited Burton on the Wolds Leicestershire LE12 5TH UK Tel 44 0 1509 882 737 Fax 44 0 1509 882 786 Asia Pacific Cooper Electronic Technologies 1 Jalan Kilang Timor 06 01 Pacific Tech Centre Singapore 159303 Tel 65 278 6151 Fax 65 2...

Page 5: ...pacity ELECTRICAL CHARACTERISTICS of Amp Rating Opening Time 125 1 Hours Minimum 200 2 Minutes Maximum 200 1 Second Minimum 1000 0 01 0 1 Seconds SPECIFICATIONS Voltage Interrupting DC Cold Typical Typical Max Marking Product Code Rating Rating Resistance ohms Melting Voltage Voltage Code AC DC 250VAC 125VDC min typ max I2 t Drop Drop 1025T250mA 250V 125V 100A 50A TBD TBD TBD TBD TBD 800 Dt 1025T5...

Page 6: ...2645 Fax 1 561 742 1178 This bulletin is intended to present product design solutions and technical information that will help the end user with design applications Cooper Electronic Technologies reserves the right without notice to change design or construction of any products and to discontinue or limit distribution of any products Cooper Electronic Technologies also reserves the right to change...

Page 7: ... Cold Typical Typical Marking Product Code Rating Rating Resistance ohms Melting Voltage Code AC DC 250VAC 125VDC min typ max I2 t Drop 1025F250mA 250V 125V 100A 50A TBD TBD TBD TBD TBD D f 1025F500mA 250V 125V 100A 50A TBD TBD TBD TBD TBD F f 1025F800mA 250V 125V 100A 50A TBD TBD TBD TBD TBD KK f 1025F1A 250V 125V 100A 50A TBD TBD TBD TBD TBD H f 1025F1 6A 250V 125V 100A 50A TBD TBD TBD TBD TBD M...

Page 8: ... Brick Fuses 1025F Series Fast Acting Low Breaking Capacity Visit us on the Web at www cooperET com 3601 Quantum Boulevard Boynton Beach Florida 33426 8638 Tel 1 561 752 5000 Toll Free 1 888 414 2645 Fax 1 561 742 1178 This bulletin is intended to present product design solutions and technical information that will help the end user with design applications Cooper Electronic Technologies reserves ...

Page 9: ...op Measured at rated current after temperature stabilizes Device designed to carry rated current for four hours minimum An operating current of 80 or less of rated current is recommended with further derating required at elevated ambient temperatures 1 35 25 1 35 25 0 053 010 0 053 010 2 59 25 0 102 010 6 10 25 0 240 010 1 35 25 1 35 25 0 053 010 0 053 010 2 59 25 0 102 010 6 10 25 0 240 010 Land ...

Page 10: ... intended to present product design solutions and technical information that will help the end user with design applications Cooper Electronic Technologies reserves the right without notice to change design or construction of any products and to discontinue or limit distribution of any products Cooper Electronic Technologies also reserves the right to change or update without notice any technical ...

Page 11: ...hms Melting Voltage Code AC DC 250VAC 125VDC 60VDC Typical I2 t Drop 1025FA250mA 250V 125V 50A 50A 5 0000 0 1212 2019 mV AD 1025FA500mA 250V 125V 50A 50A 1 2000 0 0415 1500 mV AF 1025FA750mA 250V 125V 50A 50A 0 6000 0 143 880 mV AG 1025FA1A 250V 125V 50A 50A 0 3000 1 750 560 mV AH 1025FA1 5A 250V 125V 50A 50A 0 1040 1 460 260 mV AK 1025FA2A 250V 125V 50A 50A 0 0800 6 086 258 mV AN 1025FA2 5A 250V ...

Page 12: ...intended to present product design solutions and technical information that will help the end user with design applications Cooper Electronic Technologies reserves the right without notice to change design or construction of any products and to discontinue or limit distribution of any products Cooper Electronic Technologies also reserves the right to change or update without notice any technical i...

Page 13: ...aximum SPECIFICATIONS Voltage Interrupting DC Cold Typical Typical Marking Product Code Rating Rating Resistance ohms Melting Voltage Code AC DC 250VAC 125VDC Typical I2 t Drop 1025TD250mA 250V 125V 50A 50A 4 200 0 128 1900 mV DD 1025TD500mA 250V 125V 50A 50A 0 5500 1 47 455 mV DF 1025TD750mA 250V 125V 50A 50A 0 317 0 93 400 mV DG 1025TD1A 250V 125V 50A 50A 0 2030 9 91 387 mV DH 1025TD1 5A 250V 12...

Page 14: ...intended to present product design solutions and technical information that will help the end user with design applications Cooper Electronic Technologies reserves the right without notice to change design or construction of any products and to discontinue or limit distribution of any products Cooper Electronic Technologies also reserves the right to change or update without notice any technical i...

Page 15: ...code 500mA from A to F and 1 25A from B to J 6 8 00 DR EC I Detail marking specification in section 7 4 28 00 DR EC H Add maximum total clearing I2 t in section 5 5 1 19 00 DR EC G Added nickel flash Added cold resistance for TCP 500mA min 0 541 typ 0 614 max 0 686 Added typ Melt I2 t 500mA 1 3a2 sec 1 25A 22 2 a2 sec Added typ Voltage drop on 500mA 471mV changed voltage drop of 1 25A to 205mV Add...

Page 16: ...es the right to change or update without notice any technical information contained in this bulletin Once a product has been selected it should be tested by the user in all possible applications Table of Contents Section Title Page 1 Scope 3 2 Manufacturer and Production Facility 3 3 Catalog Symbol and Part Numbering System 3 4 Mechanical Specifications 4 5 Electrical Specifications 6 6 Standards ...

Page 17: ...rd Boynton Beach FL 33426 Phone 561 752 5000 Fax 561 742 0134 2 2 Production Facility 1 Bussmann 2 NO 59 12 9 Lin 114 Old State Road Ta Tsuo Li Chu Nan Chen Ellisville MO 63021 USA Mia LiHsien Taiwan R O C 3 Xin Min Industrial Estate 4 1K M Al Este Del Aeropurto Changan DongGuan Juan Santamarita Zona Franca Guangdong Province China Saret Edificio B 05 Rio Segundo Alajuela Costa Rica 2 3 ISO Regist...

Page 18: ...ATIONS 4 1 Construction drawing not to scale 1 2 3 4 5 6 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000000000000000000000000000000...

Page 19: ... limit distribution of any products Bussmann also reserves the right to change or update without notice any technical information contained in this bulletin Once a product has been selected it should be tested by the user in all possible applications 4 2 Dimensions drawings not to scale 4 2 1 End View mm inches 2 77 0 15 0 109 0 006 2 77 0 15 0 109 0 006 4 2 2 Top View mm inches 1 40 0 25 1 40 0 2...

Page 20: ... right to change or update without notice any technical information contained in this bulletin Once a product has been selected it should be tested by the user in all possible applications 4 2 4 Orthogonal View 5 ELECTRICAL SPECIFICATIONS 5 1 Voltage Rating Catalog Symbol Voltage Rating AC TCP500mA 250 V TCP1 25A 250 V TCP2A 250 V 5 2 Interrupting Rating 5 2 1 AC Interrupting Rating Measured at de...

Page 21: ...ng Opening Time 100 4 Hours Minimum 250 1 Second Minimum 250 4 10 Seconds Typical 250 120 Seconds Maximum 300 10 Seconds Maximum If the device does not open at 250 within 120 seconds increase current to 300 of amp rating Device must open in 10 seconds maximum 5 3 2 For TCP2A Current Level Opening Time 2 2A 30 minutes minimum 7A opens before Bussmann MDL 2 25A opens before Bussmann MDL 2 40A opens ...

Page 22: ...any technical information contained in this bulletin Once a product has been selected it should be tested by the user in all possible applications 5 5 I 2 t 5 5 1 Typical Melt I 2 t is measured with a battery bank at 60V DC 10x rated current time constant of calibrated circuit less than 50 microseconds 5 5 2 Maximum Total Clearing is measured on a 40A 600V AC unity power factor circuit Catalog Sym...

Page 23: ...Sec Current A Voltage V Performance Requirement FCC 47 Part 68 Longitudinal Type B 2 5x320 37 5 N A Fuse cannot open FCC 47 Part 68 Metallic Type A 2 10x560 100 800 Fuse must open safely Surge Out 25 10x160 65 N A Fuse cannot open b TCP1 25A and TCP2A tested to surge specifications listed below Surge Specification Surge Repetitions Waveform µSec Current A Voltage V Performance Requirements FCC 47 ...

Page 24: ... help the end user with design applications Bussmann reserves the right without notice to change design or construction of any products and to discontinue or limit distribution of any products Bussmann also reserves the right to change or update without notice any technical information contained in this bulletin Once a product has been selected it should be tested by the user in all possible appli...

Page 25: ...ght without notice to change design or construction of any products and to discontinue or limit distribution of any products Bussmann also reserves the right to change or update without notice any technical information contained in this bulletin Once a product has been selected it should be tested by the user in all possible applications 6 STANDARDS and APPROVALS 6 1 UL Recognition Card JDYX2 E191...

Page 26: ...otice to change design or construction of any products and to discontinue or limit distribution of any products Bussmann also reserves the right to change or update without notice any technical information contained in this bulletin Once a product has been selected it should be tested by the user in all possible applications 6 2 CSA Component Acceptance Card 500mA and 1 25A 2A is approved but the ...

Page 27: ...duct has been selected it should be tested by the user in all possible applications 7 MARKING SPECIFICATION 7 1 A two letter alpha code will be marked on the body of the fuse The first letter will indicate the ampere rating The second letter will indicate the manufacturing facility 7 1 1 Table of alpha code marking Ampere 1st position Manufacturing 2nd position Rating alpha code Facility Location ...

Page 28: ...ice any technical information contained in this bulletin Once a product has been selected it should be tested by the user in all possible applications 9 LAND PATTERN mm inches 5 2 3 7 0 204 0 145 4 0 0 157 12 6 0 496 10 TEMPERATURE DERATING CURVE 10 1 Normal Operating Temperature 25 C 2 C 77 F 3 6 F 10 2 Maximum Operating Temperature 55 C to 125 C with proper correction factor applied 10 2 2 Chart...

Page 29: ...e user in all possible applications 11 PACKAGING SPECIFICATION 11 1 SP1 10 pieces of fuses on 24mm tape 8 mm pitch per EIA Standard 481 packaged in a plastic bag 11 2 SP2 50 pieces of fuses on 24mm tape 8 mm pitch per EIA Standard 481 packaged in a plastic box 11 3 TR1 1000 pieces of fuses on 24mm tape and reeled on a 13 inch 330 mm reel per EIA Standard 481 8 mm pitch 11 4 TR2 2500 pieces of fuse...

Page 30: ...carry test is complete half of the samples are subjected to the Maximum Current Carry Test with the remaining samples subjected to the Time Current Characteristic Curve Generation 13 2 6 The other group is tested to the destructive Current Overload Test 13 3 Moisture Resistance Test MIL STD 202 Method 106E except 13 3 1 Samples are placed in a temperature moisture chamber and subjected to 50 cycle...

Page 31: ...f twenty 13 5 4 One set is tested to the non destructive 100 current carry test After completion the samples are subjected to the Time Current Characteristic Curve Generation 13 5 5 The other set is subjected to the destructive Current Overload Test 13 6 Maximum Current Carry Test 13 6 1 Performed after the non destructive Load Humidity and 100 Current Carry Tests same samples used 13 6 2 At the c...

Page 32: ...dition D except 13 10 1 Test boards mounted to a shock test fixture which in turn was mounted to the table of the shock machine 13 10 2 Samples subjected to a simple harmonic motion having an amplitude of 20g peak 20 13 10 3 Vibration frequency is varied logarithmically from 10 to 2 000 Hz 13 10 4 Cycle is performed 12 times in each of the three mutually perpendicular directions 13 10 5 At the com...