Summary of Contents for PSG013

Page 1: ...1291 42 Arrow Road Toll 800 426 8979 North America only Guelph Ontario Fax 519 836 4878 N1K 1S6 Email sales connecttech com www connecttech com support connecttech com CTIM 00428 Revision 0 00 Sept 16 2014 Xtreme PSU UC Users Guide ...

Page 2: ...d by copyright All rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of Connect Tech Inc Copyright 2013 by Connect Tech Inc Trademark Acknowledgment Connect Tech Inc acknowledges all trademarks registered trademarks and or copyrights referred to in this document as the property of their respective owners N...

Page 3: ...put Power 11 Input Power Circuit Diagram 11 Technical Specifications 11 Input Power Connector Pinout 11 Output Power 12 Technical Specifications 12 Output Power Connector Pinout 12 Configuration Jumpers 13 J1 Charge Voltage Control Jumper 13 RS 232 Connector Pinout P4 13 External Module Charging 14 Remote ON OFF Functionality 14 Turn Supply ON 14 Turn Supply OFF 15 Software Interface 16 RS 232 16 ...

Page 4: ...bjected to abuse misuse accident disaster or non Connect Tech Inc authorized modification or repair You may obtain warranty service by delivering this product to an authorized Connect Tech Inc business partner or to Connect Tech Inc along with proof of purchase Product returned to Connect Tech Inc must be pre authorized by Connect Tech Inc with an RMA Return Material Authorization number marked on...

Page 5: ...one or the Knowledge Database in the Support Center on the Connect Tech Inc website for product manuals installation guides device driver software and technical tips Submit your technical support questions to our customer support engineers via the Support Center on the Connect Tech Inc website Telephone Facsimile Technical Support representatives are ready to answer your call Monday through Friday...

Page 6: ...ability to charge monitor and switch from main supply to a backup SMART battery providing transparent backup power to all voltage outputs The Xtreme PSU UC is a Level 2 SMART battery charger and works with all SMART batteries supporting charge voltages up to 16V and charging current up to 4A ESD Warning Electronic components and circuits are sensitive to ElectroStatic Discharge ESD When handling a...

Page 7: ...ut Overvoltage Protection Remote ON OFF control via SHUTDOWN switch USB UART and RS 232 12V Output 5A 60W maximum 1 Output regulation 40mV p p ripple at full load Output Current Limiting Protection Output Overvoltage Protection Remote ON OFF control via SHUTDOWN switch USB UART and RS 232 5V Standby Output 1A 5W maximum 1 Output regulation accuracy 15mV p p ripple at full load Current limiting pro...

Page 8: ...Connect Tech Xtreme PSU UC User Manual Revision 0 00 8 Board Diagram Functional Block Diagram ...

Page 9: ...age PSG013 5V 10A 12V 5A 5VSB 1A Other available ordering options 5V or 12V output only build option available Aluminum caps removed replaced for vacuum application To order any of these part numbers or to inquire about the other available ordering options please contact sales connecttech com for further information ...

Page 10: ...mbedded SBC To install the Xtreme PSU UC in your system please follow these steps 1 Ensure your DC input power is OFF 9V to 36V 2 Install standoffs into system 3 Insert Xtreme PSU UC onto stack bottom middle or top 4 Ensure board is bolted screwed into stack 5 Connect any external power connections to the Xtreme PSU UC s External Power Connector 6 Connect input power connection to the Xtreme PSU U...

Page 11: ...Input Power Connector Pinout The input power connector on the Xtreme PSU UC is a standard 2 pin 5mm pitch terminal block w screw flange connector that mates to a 5mm screw terminal plug with or without flange With your purchase of the Xtreme PSU UC you will have received a mating plug connector below is a list of plug part numbers that are compatible with the PSG Input Power Connector Plug Compati...

Page 12: ...FF control via SHUTDOWN switch USB or remote RS 232 connection 5V standby power is always on and not controlled by SHUTDOWN Output Power Connector Pinout Output Power Connector Plug Compatible Part Numbers With Screw Flange Part Number 284510 8 Manufacturer TE Connectivity Part Number 1606700000 Manufacturer Weidmuller Part Number OSTTJ0811520 Manufacturer On Shore Technology Inc Part Number 39504...

Page 13: ...V WARNING DO NOT INSTALL OR UNINSTALL THIS JUMPER WHILE MAIN INPUT POWER IS CONNECTED POWERED ON For applications using the on board ultracapacitors installing the jumper setting the Charge Voltage to 24V will maximize the hold up time RS 232 Connector Pinout P4 Pin No Description Direction 1 NC N A 2 NC N A 3 RX RS 232 Receive Input 4 RTS RS 232 RTS Output 5 TX RS 232 Transmit Output 6 CTS RS 232...

Page 14: ... custom firmware can be designed to exactly fit your needs Remote ON OFF Functionality The Xtreme PSU UC incorporates remote ON OFF functionality in order to necessitate remotely turning the Xtreme PSU ON or OFF from a mechanical switch or digital I O It also supports supply shutoff and start up in software via the USB or RS 232 serial interfaces 5V Standby Functionality The 5V Standby power will ...

Page 15: ...F Connecting the SHUTDOWN pin to ground the Xtreme PSU UC 5V and 12V will turn OFF Alternatively the Xtreme PSU UC can be turned OFF by driving the SHUTDOWN pin to a voltage below 1 3V Connection Example A Mechanical Switch Method Connection Example B External I O Control Method ...

Page 16: ...ELP Display a list of available functions from this table STARTUP X Startup power supply in specified number of seconds X 12V 5V SHUTDOWN X Shutdown power supply in specified number of seconds X 12V 5V TEMP0 Display the temperature of Temp Sensor 0 C TEMP1 Display the temperature of Temp Sensor 1 C USB The Xtreme PSU UC includes an on board USB port for monitoring and control of the power outputs ...

Page 17: ...e Xtreme PSU UC power sequencing during initial power up The default sequencing is of the following order 5V SB 5V 12V If your system requires a different sequence adjusted parameters or default startup shutdown delay please contact support connecttech com and a custom board can be ordered to exactly fit your needs VIN 24V VIN 10V ...

Page 18: ...Connect Tech Xtreme PSU UC User Manual Revision 0 00 18 Detailed Specifications and Derating Graphs All temperature deratings based on test results in a 125CFM test chamber Input Voltage Input Voltage ...