background image

Hunan Next Generation Instrumental T&C Tech. Co., Ltd.

NGI

l

NGI

N3410 Series

Triple-channel Programmable DC Power Supply

N3410 Series Triple-channel

Programmable DC Power Supply

User Manual

©

Copyright Hunan Next Generation Instrumental T&C Tech. Co., Ltd.

Version: V20211014

Summary of Contents for N3410 Series

Page 1: ...al T C Tech Co Ltd NGI l NGI N3410 Series Triple channel Programmable DC Power Supply N3410 Series Triple channel Programmable DC Power Supply User Manual Copyright Hunan Next Generation Instrumental T C Tech Co Ltd Version V20211014 ...

Page 2: ...kage Contents and Accessories 5 3 2 3 Appearance Dimension 6 3 3 Front Panel Introduction 7 3 4 Rear Panel Introduction 9 3 5 Power on Test 10 4 OPERATION 11 4 1 Menu 11 4 2 Output Interface Wiring 12 4 3 Basic Operation 13 4 3 1 Channel Switch 13 4 3 2 Voltage Current Setting 13 4 3 3 Protect Setting 14 4 3 4 Output Mode Setting 16 4 3 5 Configuration 20 4 3 6 Timer 21 4 3 7 SEQ 22 4 3 8 SEQ Edit...

Page 3: ...ions and maintains close ties with many industry leaders We strive to develop high quality technology leading products provide high end technologies and continue to explore new industry measurement and control solutions About User Manual This manual is applied to N3410 series programmable DC power supply including installation operation specifications and other detailed information The copyright o...

Page 4: ...se Ensure to have installed the fuse correctly Do not open the chassis The operator cannot open the instrument chassis Non professional operators are not allowed to maintain or adjust it Do not operate under hazardous conditions Do not operate the instrument under flammable or explosive conditions Confirm the working range Make sure the DUT is within N3410 s rated range 2 2 Safety Symbols Please r...

Page 5: ...o negative polarity of DUT please make sure the output floating voltage should be not greater than 60VDC The maximum floating voltage to ground is 60VDC Using non insulated short circuit conductor If insulators are used instead of non insulated metal short circuit bars or these short circuit bars are removed from the terminals so that no operator can touch the non insulated output conductors the m...

Page 6: ...ively on the 4 3 inch LCD screen DVM measurement function is optional 3 1 1 Features Each channel isolated programmable and controllable High accuracy and resolution as low as 0 1mV 0 1mA1 Low ripple noise Vrms less than 400μV Vp p less than 5mV Dynamic response time less than 1ms Sequence SEQ test function2 Half 19 inch 2U size with tilt stand Graph for real time output waveform display3 Programm...

Page 7: ...ckage Contents and Accessories After receiving N3410 please check the instrument according to the following steps 1 Check whether the instrument is damaged during transportation If any severe damage to the package please contact our authorized distributor or NGI 2 Check accessories 3 Make sure the the following accessories are attached Table 3 N3410 Accessories Instructions Power cord For AC power...

Page 8: ... 3 Appearance Dimension Programmable DC Power Supply N3413E 32 03 32V 3A 2CH 6V 3A Unlock CH1 CH2 CH3 ESC Enter Loc k CH3 0 CH2 3 6 9 CH1 2 5 8 All 1 4 7 CH 214 0 88 0 Figure 1 Front Panel Dimension mm LAN RS485 AC IN 214 0 88 0 Figure 2 Rear Panel Dimension mm Note For N3411E N3412E N3413E sense terminals are not available ...

Page 9: ...Dimension mm N3411 N3411P N3411E 446 00 15 0 88 0 15 0 22 6 Figure 4 Side Dimension mm N3412 N3412P N3412E N3413 N3413P N3413E 3 3 Front Panel Introduction DC Power Supply N3411E 32V 3A 2CH 6V 3A 1CH Unlock CH1 CH2 CH3 ESC Enter 0 3 6 2 5 1 4 Loc k 9 8 7 CH3 CH2 CH1 All CH Figure 5 Front Panel Table 4 Number Name Function 1 Device model Displaying model number ...

Page 10: ... To exit To delete To move the cursor 2 Screen Displaying data 3 USB port For USB flash drive connection 4 Power switch Power control 5 Switch button Shortcut button for the function at the bottom of screen 6 Output interface Output interface red for positive black for negative 7 Knob left right arrow By rotating knob to select the required item adjust the parameter By pressing knob to enter the e...

Page 11: ... Co Ltd NGI l NGI N3410 Series Triple channel Programmable DC Power Supply 9 3 4 Rear Panel Introduction LAN RS232 AC IN Figure 6 Rear Panel Table 6 Number Name 1 RS232 interface 2 LAN port 3 Output interface 4 AC power socket 5 Grounding screw ...

Page 12: ...input socket If N3410 cannot be started properly please refer to the following steps 1 Check whether the power cord is properly connected 2 Check whether the power is switched on 3 Check whether the fuse is burned out If yes please replace it Please use the proper fuse When replacing please open the plastic cover at the AC power socket For more support please contact NGI Warning The three core pow...

Page 13: ...nnection icon When this icon shows it means N3410 has been connected to PC or other control devices through the Ethernet cable 3 USB connection icon When this icon shows it means a USB flash drive has been connected to N3410 through the USB port 4 Beeper icon When this icon shows it means beeper setting is ON 5 Channel icon It shows the channel number of three channels 6 Alarm The protection of sp...

Page 14: ...ly pressing the corresponding button under V I Set 15 Mode switch There are fours options normal series parallel and trace 16 Config Users can configure the system parameters 17 More There are extra four options Timer SEQ Graph and About Us 18 The readback and setting interface of three channels The first channel is red The second channel is yellow The third channel is green 19 The present mode se...

Page 15: ...od 1 Press the button below Channel on the screen Method 2 Press CH on the front panel 4 3 2 Voltage Current Setting Take channel 2 for example to set voltage and current 1 Press button below Channel on the screen to switch to channel 2 2 Press button below V I Set on the screen and move cursor to voltage current setting area 3 Press or Enter 4 Input digit by pressing numeric buttons or pressing t...

Page 16: ...N3412 N3413 OVP Setting Range CH1 CH2 3 34 12V 3 34 12V 3 63 5V OCP Setting Range CH1 CH2 1 3 25A 1 5 35A 1 3 25A OVP Setting Range CH3 3 6 8V OCP Setting Range CH3 1 3 25A Steps to set protection parameters 1 Press button below Protect on the screen 2 Press or Enter on OVP OCP setting area 3 Input digit by pressing numeric buttons or pressing to move the cursor and rotate to adjust the value 4 Pr...

Page 17: ...ether OVP OCP setting value is lower than output voltage current If this is not the case please contact our authorized distributor or NGI CH1 CH2 CH3 Acive Load Figure 11 Active load wiring diagram Note When overvoltage overcurrent occurs the protection circuit inside N3410 will shut off output If an active load such as a battery is connected to N3410 output interface when overvoltage overcurrent ...

Page 18: ... The other three optional output modes are parallel PARALL series SERIES and trace TRACE modes Users can switch to the corresponding mode by pressing the corresponding button below the different modes as shown in the figure below Figure 12 Output Mode Setting 4 3 4 1 Parallel Mode Please press the button below PARALL on the screen and switch to parallel mode Figure 13 Parallel Mode In parallel mod...

Page 19: ... Wiring Diagram Steps to set voltage and current in parallel mode 1 Press or Enter on voltage current setting area 2 Input digit by pressing numeric buttons or pressing to move the cursor and rotate to adjust the value 3 Press or Enter to confirm the setting After completing setting please press C H 1 ON icon will show at channel 1 and channel 2 The power supply starts output 4 3 4 2 Series Mode P...

Page 20: ...n in the figure below CH1 CH2 CH3 Load Figure 16 Series Mode Wiring Diagram Steps to set voltage and current in series mode 1 Press or Enter on voltage current setting area 2 Input digit by pressing numeric buttons or pressing to move the cursor and rotate to adjust the value 3 Press or Enter to confirm the setting After completing setting please press C H 1 ON icon will show at channel 1 and chan...

Page 21: ... 3A following channel 1 The trace connection method is shown in the figure below CH1 CH2 CH3 Load Figure 18 Trace Mode Wiring Diagram Steps to set voltage and current in trace mode 1 Press or Enter on voltage current setting area 2 Input digit by pressing numeric buttons or pressing to move the cursor and rotate to adjust the value 3 Press or Enter to confirm the setting After completing setting p...

Page 22: ...s button below Config on the screen to enter configuration interface 2 Press button below IP on the screen 3 Press or Enter on IP address setting area 4 Input digit by pressing numeric buttons or pressing to move the cursor and rotate to adjust the value 5 Press or Enter to confirm the setting 6 Press buttons below Baud Rate Beeper Sample Rate Output Pos separately 7 Press or Enter on Baud Rate So...

Page 23: ...unction turned off Every time a channel output is turned on the countdown will start again Figure 20 Timer Setting Steps to set parameters under Timer 1 Press to find more functions 2 Press button below Timer on the screen to enter timer interface 3 Press button below Second on the screen 4 Press or Enter on time setting area 5 Input digit by pressing numeric buttons or pressing to move the cursor...

Page 24: ...to select the required state 10 Press or Enter to confirm the setting 4 3 7 SEQ Please press to find more functions and press button below SEQ on the screen Figure 21 SEQ Interface Run Stop Pause Cont pause or continue Channel channel switch Edit SEQ file edit 4 3 8 SEQ Edit Please press button below Edit on the screen under SEQ interface ...

Page 25: ...setting procedure is as follows Rotate or press to move cursor to Step Press or Enter Input digits by numeric buttons Press or Enter to confirm setting Delete delete the present step Clear clear all steps Save Load save or download Please press button below Save Load on the screen to enter SEQ Load interface Please rotate or press to move to the required parameter There are four parameters Operati...

Page 26: ...or 0 9 File name set file name Start Load After N3410 is turned on the device will load the file saved in this location to the local location 4 3 9 Graph Please press to find more functions and press button below Graph on the screen The Graph interface can display the real time graph of voltage and current of the specific channel as shown in the figure below Figure 24 Graph Interface CH1 CH2 CH3 s...

Page 27: ...ase do the following necessary inspection to eliminate the troubles which can save your maintenance and time cost If the troubles cannot be recovered please contact NGI The inspection steps are as below Check whether the device is powered Check whether the device can be turned on normally Check whether the fuse has no damage Check whether other connectors are correct including wire cables plug etc...

Page 28: ...l Power 210W 338W Setting Resolution Voltage 0 1mV 1mV 0 1mV 1mV Setting Resolution Current 0 1mA 1mA 0 1mA 1mA Setting Accuracy Voltage 23 5 0 01 10mV 0 03 10mV 0 01 10mV 0 03 10mV Setting Accuracy Current 23 5 0 05 5mA 0 05 10mA 0 05 10mA 0 05 10mA Setting Temperature Coefficient 30ppm Readback Resolution Voltage 0 1mV 1mV 0 1mV 1mV Readback Resolution Current 0 1mA 1mA 0 1mA 1mA Readback Accura...

Page 29: ...d Regulation Current 0 01 3mA 0 02 3mA 0 01 3mA 0 02 3mA DVM Measurement For N3411P N3412P Only Channels 1CH Voltage Range 600V 60V 6V Measurement Resolution 5 bits Measurement Accuracy 0 01 0 01 F S Measurement Frequency 4Hz Input Impedance 10MΩ Terminal Pluggable terminal Temperature Coefficient 0 40 20ppm Others Isolation Output to Ground 500V DC Communication Response Time 5ms Interface LAN RS...

Page 30: ...curacy Voltage 23 5 0 02 20mV 0 03 10mV Readback Accuracy Current 23 5 0 05 5mA 0 05 10mA Readback Temperature Coefficient 30ppm Long term Stability 50ppm 1000h Voltage Ripple Noise 20Hz 20MHz 10mVp p 10mVp p Voltage Ripple Noise 20Hz 20MHz 1mVrms Current Ripple Noise 20Hz 20MHz 3mArms Dynamic Characteristics Voltage Rise Time no load 10 90 F S Variation Time 20ms 20ms Voltage Rise Time full load ...

Page 31: ...0 Operating Environment Altitude 2000m relative humidity 5 90 RH non condensing atmospheric pressure 80 110kPa Net Weight Approx 11kg Dimension 2U 88 0 H 214 0 W 446 0 D mm Table 10 Model N3411E N3412E Channel CH1 CH2 CH3 CH1 CH2 CH3 Voltage 32V 6V 32V 6V Current 3A 3A 5A 3A Series Mode Voltage 64V N A 64V 5A N A Parallel Mode Current 6A N A 10A N A Total Power 210W 338W Setting Resolution Voltage...

Page 32: ... S Variation Time 400ms 200ms 400ms 200ms Voltage Fall Time full load 90 10 F S Variation Time 45ms 13ms 45ms 13ms Transient Recovery Time 1ms Line Regulation Voltage 0 01 1mV 0 01 3mV 0 01 1mV 0 01 3mV Line Regulation Current 0 01 1mA 0 02 3mA 0 01 3mA 0 02 3mA Load Regulation Voltage 0 01 3mV Load Regulation Current 0 01 3mA 0 02 3mA 0 01 3mA 0 02 3mA Others Isolation Output to Ground 500V DC Co...

Page 33: ... Accuracy Voltage 23 5 0 02 40mV 0 03 10mV Readback Accuracy Current 23 5 0 05 10mA Readback Temperature Coefficient 50ppm Long term Stability 50ppm 1000h Voltage Ripple Noise 20Hz 20MHz 10mVp p 10mVp p Voltage Ripple Noise 20Hz 20MHz 1mVrms Current Ripple Noise 20Hz 20MHz 3mArms Dynamic Characteristics Voltage Rise Time no load 10 90 F S Variation Time 20ms 20ms Voltage Rise Time full load 10 90 ...

Page 34: ...ut Single phase please refer to the voltage mark at the rear panel Temperature Operating temperature 0 40 storage temperature 20 60 Operating Environment Altitude 2000m relative humidity 5 90 RH non condensing atmospheric pressure 80 110kPa Net Weight Approx 11kg Dimension 2U 88 0 H 214 0 W 446 0 D mm Note 1 For other specifications please contact NGI Note 2 All specifications are subject to chang...