background image

OPERATION & MAINTENANCE

INSTRUCTIONS

GC0322 - Rev 1

ORIGINAL INSTRUCTIONS

SWIMMING POOL PUMP

MODEL NO: SPP07A

PART NO: 7175026

Summary of Contents for 7175026

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC0322 Rev 1 ORIGINAL INSTRUCTIONS SWIMMING POOL PUMP MODEL NO SPP07A PART NO 7175026 ...

Page 2: ...use of a non return valve will facilitate immediate priming The pump inlet is higher than the impeller inlet so that it can start operating when only the pump body is filled with water Upon receipt any damage or deficiency should be reported to your CLARKE dealer immediately CONTENTS 1 x Swimming Pool Pump c w integral Pre filter Basket 2 x Inlet Outlet Connectors 2 x Inlet Outlet Connector Fixing...

Page 3: ...ur local CLARKE dealer Always turn the pump off before carrying out any maintenance 8 NEVER modify this pump in any way Use it ONLY for the purpose for which it is designed 9 NEVER use for pumping flammable liquids or corrosive chemicals This pump is designed to pump clean water only 10 NEVER switch the pump ON when the pool is in use ALWAYS disconnect the pump from the electrical supply when the ...

Page 4: ...he markings on the plug The BLUE wire must be connected to the terminal marked N The BROWN wire must be connected to the terminal marked L The YELLOW AND GREEN wire must be connected to the terminal marked E or AN APPROVED RESIDUAL CURRENT DEVICE RCD WHICH HAS A TRIPPING CURRENT OF LESS THAN 30MA MUST BE USED If you are not sure consult a qualified electrician DO NOT try to do any repairs WARNING ...

Page 5: ...d INSTALLATION OF THE PUMP A typical installation of the pump is shown above The pump must always be installed and operated in a horizontal position i e with the outlet port facing vertically upwards The fixing holes in the base should be used to secure the pump firmly in its operating position Mount the pump on raised blocks or a purpose built platform to protect it from flooding Always ensure th...

Page 6: ...the use of suitable 50 mm I D hose secured with a worm drive clip Ensure all connections are air tight Tighten them enough to secure the hose during pressurised operation but not so tight as to crack the plastic inlet outlet connectors Where the pump is to be a permanent fixture vibration and strain on adjacent parts can be reduced by the insertion of a short flexible section of hose between any r...

Page 7: ...r in the pump can be seen through the transparent filter cover NOTE Filling the suction pipe with water will speed up the priming process and it is suggested that a non return valve be fitted to the end of the suction pipe 5 Stop the pump by switching off the power supply CARE DURING USE 1 Do not allow the pump to run dry otherwise the seal between the pump and motor may be damaged If a leak is no...

Page 8: ...u suspect the pump is blocked by silt leaf debris etc disconnect it from the mains supply and backflush to clear any blockage though the drain plug You will need to disconnect the outlet hose to do this Always keep the pump in a clean condition checking regularly for loose bolts or a damaged power cable etc AFTER USE After use and if the pump will not be used over the winter period or whenever the...

Page 9: ...ectrical and Electronic Equipment WEEE at a recognised disposal facility SPECIFICATIONS Please note that the details and specifications contained herein are correct at the time of going to print However CLARKE International reserve the right to change specifications at any time without prior notice Model Number SPP07A Pump type Centrifugal Weight 10 36 kg Dimensions L x W x H 555 x 185 x 275 mm Ma...

Page 10: ...uns but give poor output Pump inlet filter basket is blocked Check and clean filter basket Congested material inside pump Clean out filter basket backflush pump Suction or delivery line obstructed Remove obstruction and ensure there are no kinks in delivery line Inlet pipe leakage Check inlet pipe connector for leaks Tighten as required Air leaks through damaged seal Renew seal Impeller damaged an...

Page 11: ...ater Adjust inlet outlet valves in system to decrease water flow Resistance in inlet pipe aused by obstruction Check pipe and clean out as necessary Loose rotating component Return to your CLARKE dealer for repair Pump installation is unstable Stop pump and re position Air pocket in pump or pipeline Release drain plug in impeller housing to release air Damaged impeller Return to your CLARKE dealer...

Page 12: ...12 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM ...

Page 13: ... clip 13 ST6 3 x19 Self tapping screw 44 ST4 2 x 14 Self tapping screw 14 Sealing ring 45 Connection knob 15 Diffuser 46 Spring washer 16 Impeller 47 M4 x 6 bolt 17 Mechanical seal 48 Seal sheath 18 Base casting 49 Seal mat 19 Base sealing washer 50 Cover box nut 20 Casing seal 51 Power cable 21 Casing end cover 52 Circlip for shaft 22 Flat washer 53 Rotor 23 Spring washer 54 6204 Ball bearing 24 ...

Page 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com UK DECLARATION OF CONFORMITY ...

Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com EU DECLARATION OF CONFORMITY ...

Page 16: ......