background image

Summary of Contents for Net-X

Page 1: ......

Page 2: ...written consent from Chauvet Document Printing For better results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 297 mm configure your printer to scale the content accordingly Intended Audience Any person in charge of installing operating and or maintaining this product should completely read through this manual before installing operating or mai...

Page 3: ...icast 10 Signal Connection Diagram 10 Configuration And Operation 11 4 Control Panel 11 Menu Map 12 Ethernet Configuration 13 Art Net Subnet Address 13 Configuring IP Addresses 13 Configuring Art Net Net Setting 13 Configuring DMX Outputs 14 Universes 14 Art Net Universes 14 sACN Universes 14 Signal Merging 15 Indicators 15 Example Configurations 16 Example Configuration 1 Art Net and DMX Sources ...

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ...a rheostat variable resistor or dimmer ci cuit even if the rheostat or dimmer channel serves only as a 0 to 100 swi ch To eliminate unnecessary wear and improve its lifespan during pe ods of non use completely disconnect the product from power via breake or by unplugging it Fuse Replacement The Net X uses a T 250 mA 250 V fuse accessible from the bac of the product To change the fuse do the follow...

Page 9: ......

Page 10: ...CN Priority Priority is a number between 0 and 200 that is set by a controller sending an sACN signal The higher the number the higher the priority Lower priority signa will be ignored whenever there is a higher priority signal present If there is a lower priority signal present when a higher priority signal halts or stops for longer than 5 secon s the next highest priority signal will be processe...

Page 11: ......

Page 12: ......

Page 13: ... DOWN to select the Subnet addres 0 5 4 Press ENTER Configuring IP Addresses The IP addresses are the addresses of the Net X n the network They must be configured if the Net X is being used as an ethernet node In sACN mode the beginning number n b set to 2 10 or 239 In Art Net mode the beginning number s set by the Net Setting The other three numbers can be e from 0 255 The IP addresses cannot be ...

Page 14: ...ort Any one universe can be assigned to more than one DMX Out port Art Net Universes In Art Net mode there are 256 universes Universe 0 15 or every Subnet 0 15 that can be assigned to the DMX Out ports The Art Net uni erses are assigned by selecting a Subnet group and a value from 0 to 15 within that g oup To assign an Art Net universe to a DMX Out port do the following 1 Set the Subnet address se...

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ...s at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust c llec ed on the external vents 4 Clean all external surfaces with a mild solution of non ammonia cleaner isopropyl alcohol 5 Apply the solution directly to a soft lint free cotton cloth or a le s cleaning tissue 6 Make sure all connections are thoroughly dry before reconnecting power and signal cables Keep ...

Page 19: ......

Page 20: ...e and request a R turn Merchandise Authorization RMA number before shipping the product Be prepared o pr vide the model number serial number and a brief description of the cause for the return Send the merchandise prepaid in its original box and with its orig al packing and accessories Chauvet will not issue call tags Clearly label the package with the RMA number Chauvet wi refuse any product retu...

Page 21: ...Net X User Manual Rev 4 Page 21 of 21 ...