Страница 1: ...0 MS 2410 USER MANUAL Please keep the instruction manual at hand all the time for future reference ...

Страница 2: ...MATION 2 SAFETY INSTRUCTION 2 ENVIROMENTAL 3 CLEANING 3 MAINTENANCE 3 WEIGHING OPERATION 3 WARRANTY LIABILITY 4 DISPOSING OF THE SCALE 4 SPECIFICATIONS 5 KEY FUNCTIONS 6 FEATURE DESCRIPTION 7 INSTRUCTION FOR REPLACING BATTERY 8 ERROR MESSAGE 10 ...

Страница 3: ... given in the Operating Instructions They contain important instructions for installation proper use and maintenance of the device The manufacturer shall not be liable for damages arising out of failure to heed the following instructions When using electrical components under increased safety requirements always comply with the appropriate regulations Improper installation will render the warranty...

Страница 4: ...to the scales electronics you should also refrain from using corrosive liquids or high pressure washers Always disconnect the scales from the mains power supply before cleaning MAINTENANCE The scale does not require any routine maintenance However we recommend checking the scale s accuracy at regular intervals The regularity of these checks is dependent on the level of use and the state of the sca...

Страница 5: ... shall be accepted for damage caused through any of the following reasons Unsuitable or improper storage or use incorrect installation or commissioning by the owner or third parties natural wear changes or modifications incorrect or negligent handling overuse chemical electrochemical or electrical interference or humidity unless this is attributable to negligence on the part of CHARDER MEDICAL If ...

Страница 6: ...5 oz Accuracy 20g 0 04lb 1 0oz Weight units kg lb oz lb oz LCD Display Easy to read 1 0 LCD display with 4 1 2 digits Dimension Platform surface 20 x 14 x 2 in 500 x 350 x 50 mm Key Function ON ZERO OFF kg lb MEMORY Power Supply 9V battery 9V 12V adaptor Operation Temperature 5 35 ...

Страница 7: ... weight when the weight is at 2 of full capacity kg lb Press this key to switch unit between kg lb oz and lb oz MEMORY Press to recall and release the weighing value If the weight is less than 1kg press this key to recall the stored value of weight If the weight is greater than 1kg press this key to store the weight value ON MEMORY kg lb ZERO OFF ...

Страница 8: ...loaded weight is above 1kg and stable the arrow stops flickering To disable the Memory function please press ON ZERO OFF key again TARE TARE only works when load is over 400g When weight of subject is over 400g press ON ZERO OFF key to tare the weight When the arrow of hold flickered the TARE feature is working now Put your target on the scale and weigh ...

Страница 9: ...8 REMOVING BATTERY COVER STEP 2 STEP 1 LOCATING BATTERY COVER AT BOTTOM OF SCALE INSTRUCTION FOR REPLACING BATTERY ...

Страница 10: ...9 INSTALLING 9V BATTERY INSTALLING BATTERY COVER STEP 4 STEP 3 ...

Страница 11: ... total load exceeds the maximum capacity of the scale the display will show Err message The weight must be removed immediately from the surface If zero count is higher than the setting range the display will show Err message The scale will turn off in 30 seconds if the status continues If battery is discharged the display will show LOW The operator should replace the battery ERROR MESSAGE ...

Страница 12: ...11 Manufactured by Charder Electronic Co Ltd No 103 Guozhong Rd Dali Dist Taichung City 412 Taiwan R O C IN 1062 8048F 04 2016 ...