CC852 Thermostat and Receiver Binding Guide 

Step 1) 

Open the Cover on the back of receiver to expose the 8 DIP Switches on the back of the unit.  Move 
some of the switches to the down position and take note which switches are up and which are 
down.  For example in this photo, 3, 7 and 8 are in the down position, 1,2,4,5,6 are in the up 
position. 

 

If you wish one thermostat to control several receivers, please make sure that the same code is put 
onto all the other receivers 

Step 2) 

On the thermostat press and hold the PROG and Return Key simultaneously for 1 second to enter 
the menu.   

Press the Moon key once to get to the address code.  The display should show ADR and the current 
address.   

Press return and 1 will start flashing.  If number 1 in your code is up, press the Sun key.  If number 1 
is down, press the moon key.   

2 will start flashing.  Again if number 2 is up in your code press the Sun key or the moon key for 
down.  

Repeat for all 8 switches in your code.   

Press return to return to the menu.   

After a few seconds, it will return to the main screen.  Again press the PROG and RETURN key 
simultaneously to access the menu, then press the moon key to get to the address code.   

The display should show ADR and the numbers in your code that are in the UP position.  For our 
example it should show like this: 