background image

 

CAMSAT 

www.camsat.com 

CD06 

Transmitter and receiver  

 

 

This  set  is  used  for  remote  control  (turn  on/off)  by  means  of  any  devices  for  long 

distance. It uses the RS485 wire interface. The CD06-Rx receiver possesses six transmitters in 
it, of the current load up to 4A each. The NO (normally open) contact points are directed to 
the  term  block  and  the  NC  (normally  closed)  ones  are  directed  to  the  transmitter.  It  is 
possible  to  control  outlets  in  the  receiver  by  means  of  the  CD06-Tx  transmitter  or  the  PTZ 
keyboard. Devices possess the signalling system, by means of LED diodes, which shows the 
state of inlets in the transmitter and the state of outlets in the receiver.  

 
The CD06 set is composed of: 

 

The CD06-Tx transmitter 

 

The CD06-Rx receiver 

 

Instruction manual 

 

Guarantee card 

Technical data: 

CHARACTERISTICS 

 

THE CD06-Rx RECEIVER

 

THE CD06-Tx TRANSMITTER

 

The number of ID addresses

 

 

 

The addressing scope 

 

from  ID 100 to ID 107 

 

from ID 100 to ID 107 

 

Supply voltage 

 

10-14V DC 

 

10-14V DC 

 

Current intake (max.): 

320mA 

150mA 

Type and number of outlets, inlets  

 

6 potential-free, independently 
controlled outlets of the NO (normally 
open) and NC (normally closed) type 

 

6 independently controlled inlets 

 

The maximum current load of outlets 

 

4A 

 

 

The type of outlets 

 

Term block – screw-type 2.5 kw 

 

Term block – screw-type 2.5 kw 

 

Wire interface 

 

RS485 

 

RS485 

 

The transmission protocol type 

 

PELCO-D 

 

PELCO-D 

 

The transmission type 

8N1 

8N1 

The RS485 transmission speed

 

2400bps and 9600bps 

 

2400bps and 9600bps 

 

The work mode 

 

Bistable and Astable 

 

Bistable and Astable 

 

The temperature scope of work 

 

0 to +55 °C   with the external covering 
-20 to +55 °C  

 

0 to +55 °C    with the external 
covering -20 to +55 °C  

 

Dimensions (mm) 

78x107x28

 

69x80x28

 

Co-operation 

 

with the PTZ keyboard (PELCO-D) ;  
with the CD06-Tx transmitter 

with the CD06-Rx receiver 

 

The recommended radio module 

 

CD04 

 

CD04 

 

The work scopes: wire RS485 (with 
UTP cat. 5) 

 

1000m 

 

1000m 

 

Radio work mode with the CD04 
module 

 

6 or 14 km 

 

6 or 14 km 

 

Optional external covering 

 

Type: CDH-Rx     tightness class: IP56 

 

Type: CDH-Tx     tightness class:IP66 

 

 

Summary of Contents for CD06

Page 1: ...07 from ID 100 to ID 107 Supply voltage 10 14V DC 10 14V DC Current intake max 320mA 150mA Type and number of outlets inlets 6 potential free independently controlled outlets of the NO normally open and NC normally closed type 6 independently controlled inlets The maximum current load of outlets 4A The type of outlets Term block screw type 2 5 kw Term block screw type 2 5 kw Wire interface RS485 R...

Page 2: ...e inlets IN 4 IN 6 control the outlets OUT 4 OUT6 of the second receiver this option gives a possibility to connect e g four transmitters controlling three outlets in eight receivers in one bus bar Preparing the CD06 set for work It is recommended to make the first start and configuration of the system in workshop conditions in small distance It can save much valuable time in the configuration of ...

Page 3: ... in a correct way by the receiver and the LED indicators are alight in accordance with the state of outlets in the receiver Turning on the function PIN8 ON 2 Reading states from the EEPROM memory before the power cut The receiver and the transmitter are equipped with volatile memory in which the last states of the receiver s outlets and the indicators of the transmitter s inlets are registered Aft...

Page 4: ...control several transmitters PTZ keyboards at once in one network it has to be done in turn Configuration of the CD06 set The whole configuration is made by means of switches of the Dip switch type placed at the back of the device Transmitter PIN1 PIN2 PIN3 the address of the following inlets IN 1 IN3 see table No 1 Address settings PIN4 PIN5 PIN6 the address of the following inlets IN 4 IN6 see t...

Page 5: ... change in the state closing opening and not a continuous closing of the inlet Verify the correctness of SETTINGS in the CD06 Rx PIN5 and PIN6 receiver Apart from the correct connection of RS wires the devices do not communicate with one another Check if the changes in the states of inlets cause light in the TxD transmitter s indicator and the RxD receiver Check the transmission speed settings it ...

Page 6: ...ed device including the purchase date and a description of the damage 4 The warranty repair includes only damages resulting from causes included in the sold device 5 The warranty repair will be made in the shortest time possible not exceeding 14 days counting from the date of accepting the device to be repaired in the service In case of a necessity to import parts the repair date can be exceeded A...

Reviews: