Page 1 of 7

CX-EPD1289L 

Electric Preload RIM Strike

INSTALLATION INSTRUCTIONS

Electrified Locks, Relays and Timers

THIS PACKAGE INCLUDES:  

1. DESCRIPTION 

Camden CX-EPD1289L Preload RIM strike for pullman latches 
offers the very best strike quality and performance. The 
strike design delivers unparalleled application flexibility, with 
field selectable voltage, fail safe/fail secure operation and 
mechanical adjustment of the strike body. 

2. SPECIFICATIONS

Voltage 

12/24V AC/DC

Current Draw

560mA @ 12 VDC
280mA @ 24 VDC

Static Strength

1,500lbs. (UL Verified)

Dynamic Strength 

70 ft-lbs.

Preload (Fail-Secure Only)

15lbs.

Endurance 

1,000,000 Cycles (Factory Tested) 
250,000 Cycles (UL Verified)

Latch Projection

3/4"

Fire Rating

UL 10C/CAN4-S104 
3 hrs. (Fail Secure Only)

Mode

Field Selectable 
Fail Safe/Fail Secure

Mechanical Adjustment

Strike Body

Operation

AC-Buzz, DC-Silent

Duty

Continuous

Latch Bolt Monitor

SPDT, 100mA @ 24V DC Resistive

Dimensions (Body)

9-3/16"H x 1-15/16"W x 3/4"D 

(233mm x 49mm x 19.8mm)

UL 294 Performance 
Levels

- Line Security = Level I 
- Attack Level = Level I 
- Endurance Level = Level IV 
- Standby Power = Level I

3. DIMENSIONS 

UL10C/

CAN4-S104,

3hr. Fire rating

UL 1034

UL 294

(2)  4-PIN power connector 
(1)   3-PIN door status  connector
(1) Installation Jig

(4) 1/4 - 20 x 1-1/4'' Screws
(4) M3 x 6 Screws

(1)  MOV
(1)  Cover plate

9

3

16

''

 [233.0mm]

1

15
16

''

 [49.0mm]

3
4

''

 [19.8mm]

1

15
16

''

 [49.0mm]

3
4

''

 [19.8mm]

9

3

16

''

 [233.0mm]

1

15
16

''

 [49.0mm]

3
4

''

 [19.8mm]

1

15
16

''

 [49.0mm]

3
4

''

 [19.8mm]

Summary of Contents for CX-EPD1289L

Page 1: ...15lbs Endurance 1 000 000 Cycles Factory Tested 250 000 Cycles UL Verified Latch Projection 3 4 Fire Rating UL 10C CAN4 S104 3 hrs Fail Secure Only Mode Field Selectable Fail Safe Fail Secure Mechanic...

Page 2: ...te with the Jamb edge If the door keeper does not align with the template cavity Adjust the template Note 1 Open door slightly Place template on door jamb aligning templates edge with jamb edge Note 1...

Page 3: ...strike and mark the remaining 2 middle mounting screw positions on frame 5 Open the door and remove the strike from the frame drill and thread the 2 middle mounting screw holes for the 1 4 20 x 1 1 4...

Page 4: ...input wires Door Status Sensor Closed Position White N O Orange COM Grey N C Red Green Black Blue 12V 24V Black Red Blue Green 12V Varistor 24V Varistor Orange White Grey Black Red 12V 24V Blue Green...

Page 5: ...e type Fail Secure Type Fail Safe Type Step 4 Setting Fail Secure Fail Safe How to modify fail secure to fail safe or vice versa 1 Remove the cover plate Remove the 6 screws at the front of the electr...

Page 6: ...common reason for a strike failing Position the RIM strike so that the strike jaws lightly rest against the latch of the exit device Check that the door is not binding on the frame An electric strike...

Page 7: ...adlocking latch as shown here If exit device has a deadlocking latch the CX EPD1289L RIM strike must be mounted so that the deadlocking latch does not enter the latch cavity of the RIM strike Position...

Reviews: