background image

EN

USER MANUAL

Pellet Stove

ATENA

3

 PLUS 12/14 - DUKE 12/14 AIRTIGHT- SABA 12/14

MITHOS

3

 PLUS 12/14 - MITHOS PLUS 12/14 PS

©2022 CADEL srl  |  All rights reserved - Tutti i diritti riservati

New

Summary of Contents for MITHOS3 PLUS 14 PS

Page 1: ...EN USER MANUAL Pellet Stove ATENA3 PLUS 12 14 DUKE 12 14 AIRTIGHT SABA 12 14 MITHOS3 PLUS 12 14 MITHOS PLUS 12 14 PS 2022CADELsrl Allrightsreserved Tuttiidirittiriservati New...

Page 2: ...SYSETFEATURE SEESECTIONXSETTINGSMENU A PAG 14 20 8 17 PELLETS RECIPE SEE SECTION H SETTINGS MENU A PAG 14 21 8 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 14 21 8 19 CHIMNEY SWEEP FUNCTIO...

Page 3: ...ons includingthosereferringtonationalandEuropeanstandards mustbeobservedwheninstallingtheapplian ce In Italy for the installation of systems with a biomass below 35KW refer to the Ministerial Decree 3...

Page 4: ...that these operating conditions increase the risk of premature wear of the product especially those parts exposed to the direct heat of the fire e g combustion chamber theoriginalconditionofwhichcanun...

Page 5: ...r If the floor is made of combustible material we recommend using a protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles during cleaning T...

Page 6: ...roductisswitchedonforthefirsttime itisnormalforittoemitsmokeduetothepaintheatingupforthefirsttime Therefore make sure the room it is installed in is well ventilated Periodically check and empty the in...

Page 7: ...the customer must have the guarantee certificate and present it with the proof of purchase document to theTechnical Assistance Office Theguaranteedoesnotcovermalfunctionsand ordamagetotheappliancetha...

Page 8: ...es 6 DISPOSAL OF MATERIALS 6 1 WARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT The owner is the sole party responsible for demolishing and disposing of the product This must be performed in complianc...

Page 9: ...Fig 2 Wastedisposal Thissymbol whichisusedontheproduct batteries accumulatorsoronthepackagingordocuments meansthatattheendofits useful life this product the batteries and the accumulators included mus...

Page 10: ...D PE 04 SORTED waste collection PLASTIC Check the instructions of the com petent body POLYSTYRENE FOAM PEANUTS POLYSTYRENE PS 6 SORTED waste collection PLASTIC Check the instructions of the com petent...

Page 11: ...umenti Optionalonmodels SPARK11 INDIGO11 7 2 NAVEL STAND ALONE OPTIONAL Procedureifonlyvalidformodelswith NAVELSTANDALONEWi Fitechnology ATTENTION InstallationmustONLYbecarriedoutbyspecialisedpersonne...

Page 12: ...flue is efficient Switch on the stove at Power 5 for at least 2 hours in order to enable the materials which make up the boiler and the fireplace to adjust the inner springing stress After 2 hours the...

Page 13: ...grammingmenutoincrease 5 Decreasesettemperature programmingfunctions 6 Increasesettemperature programmingfunctions 7 Display 8 Time 9 Status 10 Temperature setbyuser 11 Instantpower 12 Ambienttemperat...

Page 14: ...rm With the keys select the language of interest IT EN DE FR ES NL PL DA SL Press menu to confirm and esc to exit b Cleaning To select Cleaning only when the boiler is switched off act as follows Pres...

Page 15: ...ws Press menu to confirm Scroll to Easy Set using the arrows Press menu to confirm With the keys select Easy Set of interest SET1 SET2 SET3 SET4 Press menu to confirm and esc to exit h Pellet Recipe T...

Page 16: ...ing pot is clean To start the stove keep the P1 button pressed until the ON sign and a flashing flame to its side appear The ignition resistance pre heatingstarts Aftersomesecondsthefeedscrewloadspell...

Page 17: ...as settled Afterablack outofmorethan10seconds thestoveenterstheduringshutdown Completedthisphase itstartsautomatically up with the different phases 8 10 ADJUSTMENTS MENU To access the adjustments menu...

Page 18: ...by setting 1 you can keep the ambient temperatureconstantforalongerperiod Theflamesetgoestotheminimumvalueautomaticallywhenthesettemperaturevalue is reached If only one notch appears the stove has a f...

Page 19: ...mmeproposesastart upandshutdownintimesincludedwithinanothertimerprogramme iftheboilerisalreadyon start will not have any effect while OFF will switch it off In the boiler on and timer active condition...

Page 20: ...the timer 8 16 EASY SET FEATURE SEE SECTION X SETTINGS MENU A PAG 14 Proper operation of a stove mainly depends on the flue it is connected to Once it is connected it is equally important to perform p...

Page 21: ...e 30 30 reduction with respect to the default setting 25 25 reduction with respect to the default setting 20 20 reduction with respect to the default setting 15 15 reduction with respect to the defaul...

Page 22: ...seabadcombustionandrunning sopleaseassureyouthattheyarestoredindryplacesand faratleastonemeterfromthestoveand oranyothersourceofheat It is advisable to try different type of pellets available on the m...

Page 23: ...sion alarm and proceeds to switch off Wait until it switches off then light it again Fig 26 Dooropen Fig 27 deterioratedgasket Fig 28 Timer 90seconds Tooperatecorrectly thestovemustworkwiththepelletho...

Page 24: ...tely in the special containers Fig 30 Remotecontrol LEGEND Fig 30 Button1 Increasethedesiredtemperature 5 35 C Button2 Decreasethedesiredtemperature 35 5 C Button3 On off Button4 Menu Button5 Decrease...

Page 25: ...ER ON In the event of a power cut BLACKOUT the boiler behaves as follows Blackout below 10 it returns to its operation in progress In the event of a power cut that lasts over 10 with the boiler on or...

Page 26: ...e will switch to the OFF position If the warning is still present contact a service centre 13 ROUTINE MAINTENANCE 13 1 INTRODUCTION For a long working life of the stove have a periodic cleaning of the...

Page 27: ...inted object the holes obstructed by encrustations see Fig 34 Fig 35 Burningpotboxcleaning Fig 36 Cleaningwithabrush Clean and drain away the burning pot box and ash tray box from ash which has accumu...

Page 28: ...PANELS Somestovemodelshasanexternalliningmadeupofceramicorstone Thesepiecesarehandmadethereforetheycouldinevitably present crazings seedinesses shadings To clean ceramic or stone panels use a soft and...

Page 29: ...components must only be checked by qualified personnel whose technical expertise includes combustion and electricity Werecommendforthisyearlymaintenancetobecarriedout withascheduledservicecontract Thi...

Page 30: ...r Open fire door or open pellet door Close fire door and pellet door and check that there are no pellet grains at the gasket level Clogged stove Fume chamber cleaning Auger blocked by a foreign object...

Page 31: ...ooled Faulty fume tempe rature probe Replace the fume probe Faulty mother board Replace the mother board Ash remains along the stove Faulty or out of order door gaskets Replace the gaskets Not sealed...

Page 32: ...2 109 mg Nm3 Heat output Nominal heat output Pnom 12 kW Minimum heat output indicative Pmin 3 8 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficienc...

Page 33: ...2 109 mg Nm3 Heat output Nominal heat output Pnom 14 kW Minimum heat output indicative Pmin 3 8 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 89 Useful efficienc...

Page 34: ...utput Nominal heat output Pnom 12 kW Minimum heat output indicative Pmin 3 8 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficiency at minimum heat o...

Page 35: ...utput Nominal heat output Pnom 14 kW Minimum heat output indicative Pmin 3 8 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 89 Useful efficiency at minimum heat o...

Page 36: ...CADEL srl 31025 S Lucia di Piave TV Via Foresto sud 7 Italy Tel 39 0438 738669 Fax 39 0438 73343 www cadelsrl com www free point it www pegasoheating com Rev 00 2022...

Reviews: