Owner’s Instruction and Operation Manual

U.S. Environmental Protection Agency

Certified  to  comply  with  2020  particulate 

emissions standards.

SAFETY NOTICE: If this heater is not properly installed, a house fire may result. 
For  your  safety,  follow  the  installation  instructions.  Never  use  make-shift 

compromises during the installation of this heater. Contact local building or 

fire officials about permits, restrictions and installation requirements in your 

area. NEVER OPERATE THIS PRODUCT WHILE UNATTENDED.

CAUTION! Please read this entire manual before you install or use your new room 
heater. Failure to follow instructions may result in property damage, bodily injury, 

or even death. Improper Installation Will Void Your Warranty!

Save These Instructions In A Safe Place For Future Reference.

 CALIFORNIA PROPOSITION 65 WARNING:

This product can expose you to chemicals including carbon 
monoxide, which is known to the State of California to cause 
cancer, birth defects, and/or other reproductive harm. For 
more information, go to www.P65warnings.ca.gov

853913B-2302L

AP5613

R

Report Number: F21-735

Certified  to  ASTM  E1509-12  (2017) 
and  Certified  to  ULC-S627-00-

REV1

Mobile Home Approved

Model Number:

Summary of Contents for AP5613

Page 1: ...e officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warranty Save These Instructions In A Safe Place For Future Re...

Page 2: ...O OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER S MANUAL Heating Specifications Fuel Burn Rate lowest setting 1 65 lbs hr 0 75 kg hr Pellet size may effect the actual rate of fuel feed and burn times Fuel feed rates may vary by as much as 20 Use PFI listed fuel for best results Burn Time lowest setting 30 hrs approximate Hopper Capacity 50 lbs 22 7 ...

Page 3: ... Brand___________________________________ If no Date of inspection of existing venting system _______________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as per Installation Instructions Confirm proper placement of internal parts Check soundness of door gasket and door seals Confirm clearances to combustibles as per installation instructions in this manual...

Page 4: ...led wires out of the top of the stove There will be two wire harnesses as shown 2 Unpack the top mount controls and ensure that the wiring harness shown is attached securely 3 Connect the factory installed wiring harnesses to the control panel as shown 4 Secure the control panel to the top of the stove with two sheet metal screws ...

Page 5: ...ATION A POWER SURGE PROTECTOR IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF OR OVER THE HEATER DO NOT ROUTE THE CORD IN FOOT TRAFFIC AREAS OR PINCH THE CORD UNDER FURNITURE CAUTION BURNING FUEL CREATES CARBON MONOXIDE AND CAN BE HAZARDOUS TO YOUR H...

Page 6: ...e and 1 to the rear of the appliance See diagram for further information A Back to Stove 1 26mm B Side to Stove 6 153 mm C Front to Stove 6 153 mm D Back to Flue 2 51 mm CLEARANCES Your pellet stove has been tested and listed for installation in residential mobile home in accordance with the clearances given below For safety reasons please adhere to the installation clearances and restrictions Any...

Page 7: ...ng enough to go through both a hearth pad if used and the floor of the home The heater must be electrically grounded to the steel chassis of the mobile home with 8 GA copper wire using a serrated or star washer to penetrate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and must extend a minimum or 36 914 mm above the roof line of the mobile home and must be insta...

Page 8: ...r 2 500 feet above sea level We recommend the use of Simpson Dura Vent or Metal Fab pipe if you use other pipe consult your local building codes and or building inspectors Do not use Type B Gas Vent pipe or galvanized pipe with this unit The pellet vent pipe is designed to disassemble for cleaning and should be checked several times during the burning season Pellet vent pipe is not furnished with ...

Page 9: ...mum section of pipe should be added with a horizontal cap which would complete the installation A support bracket should be placed just below the termination cap or one every 4ft 1 22m to make the system more stable If you live in an area that has heavy snowfall it is recommended that the installation be taller than 3ft 0 91m to get above the snowdrift line This same installation can be used if yo...

Page 10: ... A 6 CHIMNEY SYSTEM 1 IMPORTANT If you are installing your pellet stove as a replacement to an existing wood stove you can install your pellet stove using the existing class A 6 venting system You must have the existing chimney system cleaned and or inspected by a qualified chimney sweep before proceeding with the installation of your pellet stove 2 To the right is an example of an installation us...

Page 11: ...ween manual and controlled with a Thermostat Separate LEDs to the left of the two digit display indicate the mode of operation Manual or T Stat The stove has to be in normal operation to be switched from Manual to T Stat mode Manual mode operates according to the 5 set levels of feed on the bar graph from heat range 1 to heat range 5 T Stat mode works as follows The stove has a built in Thermostat...

Page 12: ...rting a fire in an affected wood heater Burning these materials may result in release of toxic fumes or render the heater ineffective and cause smoke PROPER FUEL ATTENTION THIS APPLIANCE IS DESIGNED FOR THE USE OF PELLETIZED FUEL THAT MEET OR EXCEED THE STANDARD SET BY THE PELLET FUEL INSTITUTE PFI Your pellet stove is designed to burn premium hardwood pellets that comply with the Pellet Fuels Ins...

Page 13: ...burn pot supplied with this heater Hopper lid must be closed in order for the unit to feed pellets During the start up period Make sure the burn pot is free of pellets DO NOT open the viewing door DO NOT add pellets to the burn pot by hand NOTE During the first few fires your stove will emit an odor as the high temperature paint cures or becomes seasoned to the metal Maintaining smaller fires will...

Page 14: ...VERFILL HOPPER TAMPER WARNING This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual SHUTDOWN PROCEDURE WARNING NEVERSHUTDOWNTHISUNITBYUNPLUGGING IT FROM THE POWER SOURCE Turning your stove off is a matter ...

Page 15: ...h 2 5 16 screws Remove the clean outs and vacuum out any accumulated ash This should be done at least once per month or more frequently if large amounts of ash are noticed while cleaning or if the stove does not seem to be burning properly If a vacuum is used to clean your stove we suggest using the AV15E AshVac vacuum The AV15E AshVac is designed for ash removal Some regular vacuum cleaner i e sh...

Page 16: ...oler surfaces tend to build creosote deposits quicker so it is important to check the chimney from the top as well as from the bottom The creosote should be removed with a brush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally inspected cleaned and if ne...

Page 17: ...This unit s door uses a 3 4 diameter rope gasket BLOWER MOTORS Clean the air holes on the motors of both the exhaust and distribution blowers annually Remove the exhaust blower from the exhaust duct and clean out the internal fan blades as part of your fall start up If you have indoor pets your power motors should be inspected monthly to make sure they are free of animal hair build up Animal hair ...

Page 18: ...usstove com The information in this owner s manual is specific to your unit When ordering replacement parts the information in this manual will help to ensure the correct items are ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached under the hopper lid Other information that may...

Page 19: ...se the slide about 1 4 after your stove cools down Restart your stove If your display shows E1 again close the slide another 1 4 and restart The convection blower is overheating and tripping the internal temperature shutoff Clean any dust off of the windings and fan blade If oiling the blower does not help the blower may be bad The stove is being left on the highest setting for extended periods of...

Page 20: ...Combustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should be a full current If there is power the blower is bad If there is not make sure the control board is sending power to the air switch Control board not sending power to combustion blower If there is no current going to th...

Page 21: ...emove the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the lower bearing of the auger Pull the auger out of the tube to free the jam The auger motor has failed Remove the auger motor from the auger shaft and try to run the unit If the motor will turn the shaf...

Page 22: ...rating the unit be sure the hopper lid is closed so that the hopper safety switch will activate Check the wires leading from the hopper safety switch to the control panel and auger motor for secure connections Use a continuity tester to test the hopper safety switch replace if necessary The auger shaft is jammed Start by emptying the hopper Then remove the auger motor by removing the auger pin Rem...

Page 23: ...o The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that has a temperature rating on 500 degree F or higher Also seal joints with UL 181 AP foil tape Also make sure the square to round adapter piece on the combustion blower has been properly sealed with th...

Page 24: ...e in the hopper so that you can see the auger shaft Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing Next remove the two nuts that hold the top auger biscuit in Then rotate the bottom end of the auger shaft up towards you until you can lift the shaft out of the stove After you have removed the shaft inspect it for bent flights burr...

Page 25: ...the consumer High limit switch is malfunctioning If the other items check out okay replace the high limit switch Glass Soot s Up At A Very Fast Rate Flame Is Lazy Dark And Has Black Tips After Stove Has Been On For A While The Burnpot Overfills Possible Causes Possible Remedies Unplug stove first when possible Stove or vent pipe is dirty which restricts airflow through the burnpot Follow all clean...

Page 26: ...ver Gasket 2 8 80630 Housing PCBA Controller 1 9 80631 Power Board 1 10 80491 Microswitch 1 11 80709 Room Blower 1 12 88347 High Temp Snapdisc Gasget 2 13 80601 High Temp Snapdisc Air 1 14 80599 T Disc Exhaust 1 15 80872 Exhaust Blower 1 16 80871 Drive Motor 3 8 RPM 1 17 88166 Gasket Exhaust Blower 1 18 80549 Vacuum Switch 1 19 80869 Ceramic Ignitor 1 20 88118 Ignitor Flange Gasket 1 IN ORDER TO M...

Page 27: ... 2022 United States Stove Company 27 1 25A 250V FUSE 7 5A 250V FUSE CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown WIRING DIAGRAM ...

Page 28: ...28 2022 United States Stove Company NOTES ...

Page 29: ...07 Date ______________________ Engineer Name ________________________________ License No _____________________________________ Company ______________________________________ Telephone No __________________________________ Stove Inspected Chimney Swept Items Replaced ________________________________ Service 02 Date ______________________ Engineer Name ________________________________ License No ___...

Page 30: ...ted States Stove Company 27 1 25A 250V Fusible 7 5A 250V Fusible CORRECT FAUX Assurez vous que les fils sont connectés aux deux broches inférieures de l interrupteur de la trémie comme illustré SCHÉMA DE CÂBLAGE ...

Page 31: ...de feu 1 6 892668 Couvercles de nettoyage des cendres 2 7 88258 Joint de couvercle de nettoyage 2 8 80630 Boîtier contrôleur PCBA 1 9 80631 Power Board 1 10 80491 Commutateur de couvercle 1 11 80709 Souffleur de pièce 1 12 88347 T Disc joint d air ambiant 1 13 80601 T Disc air ambiant 1 14 80599 T Disc échappement 1 15 80872 Souffleur d échappement 1 16 80871 Moteur de tarière 1 17 88166 Joint ventila...

Page 32: ...e ou le lot de granulés utilisés est peut être de mauvaise qualité Si possible essayez une autre marque de granulés Essayez aussi une marque composée d un autre type de bois résineux plutôt que feuillus Des bois différents présentent des caractéristiques différentes qui affectent la combustion L interrupteur de surchauffe se déclenche tout le temps Causes possibles Solutions possibles Débranchez le po...

Page 33: ... arbre de la tarière et essayez de le faire fonctionner Si le moteur tourne c est l arbre qui est coincé sur quelque chose Si le moteur ne tourne pas il est défectueux Tarière bloquée Commencez par vider la trémie Puis retirez le moteur de la tarière en retirant la goupille de la tarière Retirez la plaque d inspection de l arbre de la tarière dans la trémie pour pouvoir examiner l arbre de la tari...

Page 34: ...Le tableau de commande n envoie pas de courant à l allumeur Vérifiez la tension qui arrive à l allumeur lors du démarrage Ce doit être la tension nominale Si la tension est inférieure à la valeur nominale vérifiez le câblage Si le câblage est bon c est le tableau qui est défectueux UNE ODEUR DE FUMÉE EST REFOULÉE DANS LA PIÈCE Causes possibles Solutions possibles Débranchez le poêle avant toute ch...

Page 35: ... pour permettre à l interrupteur de sécurité de la trémie de s activer Vérifiez le branchement des fils qui partent de l interrupteur de sécurité de la trémie jusqu au tableau de commande et au moteur de la tarière Utilisez un testeur de continuité pour tester l interrupteur de sécurité de la trémie remplacer le si nécessaire L arbre de la tarière est coincé Commencez par vider la trémie Puis reti...

Page 36: ...ie Retirez ensuite le moteur de la tarière en retirant la goupille de la tarière puis retirez les deux boulons qui fixent le support de tarière au tube de tarière Vous pouvez maintenant retirer le support du tube de tarière Retirez les deux boulons du côté du tube de tarière pour déposer le roulement inférieur de la tarière Tirez sur la tarière pour la sortir du tube afin de lever le blocage Le mo...

Page 37: ... Panne du ventilateur de combustion Lorsque le poêle est en marche vérifiez si le ventilateur de combustion est en fonctionnement Sinon vérifiez l alimentation électrique du ventilateur de combustion Ce doit être la tension nominale Si l alimentation électrique est bonne c est le ventilateur qui est défectueux Si l alimentation est absente reportez vous au point No 8 Le tableau de commande n envoi...

Page 38: ... poêle Si votre écran affiche à nouveau E1 fermez la glissière de 1 4 et recommencez Le ventilateur de convection surchauffe et déclenche l arrêt de température interne Enlevez la poussière des bobinages et pales de ventilateur Si le graissage du ventilateur ne suffit pas il se peut que le ventilateur soit défectueux Le poêle est demeuré sur le réglage le plus élevé pendant de longues périodes En cas d...

Page 39: ...ropriétaire sont spécifiques à votre appareil Lors de la commande de pièces de rechange les informations contenues dans ce manuel vous aideront à vous assurer que les bons articles sont commandés Avant de contacter le service client notez le numéro de modèle et le numéro de série de cet appareil Cette information se trouve sur l étiquette de certification apposée à l arrière de l appareil D autres...

Page 40: ...SEZ PAS de nettoyants abrasifs N effectuez PAS le nettoyage lorsque la vitre est CHAUDE N essayez pas de faire fonctionner l appareil avec du verre brisé Le verre de remplacement peut être acheté auprès de votre revendeur américain Stove Si le verre est brisé suivez ces procédures de retrait 1 Retirez les quatre vis et les retenues en verre 2 Tout en portant des gants en cuir ou tout autre gant ada...

Page 41: ...age Pour nettoyer la cheminée déconnecter l évacuation du poêle CENDRES VOLANTES Elles s accumulent dans la portion horizontale du conduit d évacuation Bien qu elles ne soient pas combustibles elles peuvent gêner le flux normal d évacuation Elles doivent donc être périodiquement éliminées ENLÈVEMENT ET ÉLIMINATION DES CENDRES AVERTISSEMENT LAISSEZ LE POÊLE REFROIDIR AVANT D EFFECTUER TOUT ENTRETIE...

Page 42: ...nférieurs de l échangeur de chaleur Pour accéder à ces outs propres vous devez retirer les deux panneaux latéraux Les sorties propres sont fixées à la chambre de combustion avec 2 vis 5 16 Retirez les feuilles propres et aspirer les cendres accumulées Cela devrait être fait au moins une fois par mois ou plus fréquemment si de grandes quantités de cendres sont remarqués lors du nettoyage ou si le p...

Page 43: ... EN DESSOUS DE 1 4 PLEINE AVERTISSEMENT GARDEZ LE COUVERCLE DE LA TRÉMIE FERMÉ À TOUT MOMENT SAUF PENDANT LE REMPLISSAGE NE REMPLISSEZ PAS TROP LA TRÉMIE AVERTISSEMENT DE SABOTAGE Ce poêle à bois a un taux de combustion faible minimum défini par le fabricant qui ne doit pas être modifié Il est contraire à la réglementation fédérale de modifier ce paramètre ou d utiliser ce radiateur à bois d une m...

Page 44: ...surez vous que le pot de combustion ne contient pas de granulés N ouvrez PAS la porte de visualisation Il se peut que le registre doive être fermé pendant le démarrage N ajoutez PAS de granulés dans le pot de combustion à la main REMARQUE Au cours des premiers incendies votre poêle émettra une odeur lorsque la peinture à haute température durcit ou deviendra assaisonnée au métal Le maintien de pet...

Page 45: ...articules L interdiction de la combustion de ces matériaux n interdit pas l utilisation des démarreurs de feu fabriqués à partir de papier de carton de sciure de cire et substances similaires dans le but de déclencher un incendie dans un poêle à bois affecté Brûler ces matériaux peut entraîner la libération de fumées toxiques ou de rendre l appareil de chauffage de la fumée inefficace et cause CARBURA...

Page 46: ...e production de chaleur changent progressivement sur le diagramme en barres passant du niveau 1 au niveau 5 de chauffage C Touche C F La touche C F fait passer l affichage à deux chiffres des degrés Celsius aux degrés Fahrenheit et vice versa D TOUCHE mode M T Le Mode de fonctionnement du poêle peut être Manuel ou commandé par un Thermostat Des diodes distinctes à gauche de l écran à deux chiffres indi...

Page 47: ...n tuyau de connecteur de 6 pouces les illustrations ci dessous ne sont que des exemples Veuillez confirmer à tous les codes du bâtiment locaux ou ragulations ayant compétence avant de demander à un installateur qualifié de procéder à cette installation AVERTISSEMENT Vous voudrez peut être localiser les utilitaires ou les obstacles à l intérieur du mur avant de tenter cette installation Assurez vou...

Page 48: ...on de tuyau d au moins 3 pi 0 91 m doit être ajoutée avec un chapeau horizontal pour achever l installation Un support doit être placé juste au dessous du chapeau de sortie ou à raison d un support tous les 4 pi 1 22 m pour rendre le système plus stable Si vous vivez dans une région où la neige est abondante il est recommandé que la sortie de l installation se trouve à plus de 3 pi 0 91 m pour éch...

Page 49: ...duit d évacuation pour poêle à granulés est conçu pour être démonté aux fins de nettoyage et doit être vérifié plusieurs fois au cours de la saison de chauffage Le conduit d évacuation pour poêle à granulés n est pas fourni avec l appareil et doit être acheté séparément INSTALLATION DE L EVACUATION POUR POELE A GRANULES L installation doit comprendre un T de nettoyage pour permettre la collecte des...

Page 50: ...1 mm et doit dépasser d au moins 36 po 914 mm au dessus de la faîtière de la maison mobile elle doit être installée avec un pare feu de plafond et un chapeau anti pluie homologués UL En cas de déplacement de la maison mobile toutes les sorties extérieures doivent être déposées pendant ce déplacement Après la réimplantation toutes les sorties extérieures doivent être réinstallées et refixées Une pr...

Page 51: ... Retour à Cuisinière U S A 1 26 CAN 8 204 B Côté poêle U S A 6 153 CAN 8 204 C De l avant au poêle U S A 6 153 CAN 8 204 D Retour à Flue 2 51 DÉGAGEMENTS Votre poêle à granules a été testé et répertorié pour une installation dans une maison résidentielle et mobile conformément aux dégagements indiqués ci dessous Pour des raisons de sécurité veuillez respecter les dégagements et restrictions d inst...

Page 52: ... PASSAGE ET NE LE COINCEZ PAS SOUS LES MEUBLES ATTENTION ATTENTION LA COMBUSTION DU COMBUSTIBLE GÉNÈRE DU MONOXYDE DE CARBONE QUI PEUT S AVÉRER DANGEREUX POUR LA SANTÉ EN L ABSENCE D UNE VENTILATION APPROPRIÉE ATTENTION UN DÉTECTEUR DE FUMÉE FONCTIONNEL DOIT ÊTRE INSTALLÉ DANS LA PIÈCE OÙ SE TROUVE LE POÊLE INSTALLEZ UN DÉTECTEUR DE FUMÉE À CHAQUE ÉTAGE DE VOTRE MAISON EN CAS D INCENDIE ACCIDENTEL...

Page 53: ... comme illustré 2 Déballez les meilleurs contrôles de montage et de veiller à ce que le faisceau de câblage illustré est fixé 3 Connecter les installés en usine faisceaux de câblage sur le panneau de commande comme indiqué 4 Fixez le panneau de commande au dessus du poêle avec deux vis à tôle POUR LE SERVICE À LA CLIENTÈLE APPELER 800 750 2723 EXT 5050 ...

Page 54: ...non date d inspection du système de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conformément aux instructions d installation Confirmer le bon placement des pièces internes Vérifier la solidité du joint de porte et des joints de porte Confirmer les dégagements aux combustibles selon les instructi...

Page 55: ...anuel décrit l installation et le fonctionnement du poêle à bois USSC 5710 XH Cet appareil de chauffage respecte les limites d émission de bois de berceau de l Environmental Protection Agency des États Unis de 2020 pour les appareils de chauffage au bois vendus après le 15 mai 2020 Dans des conditions de test spécifiques il a été démontré que cet appareil de chauffage fournit de la chaleur à des taux...

Page 56: ...les restrictions et les exigences d installation dans votre région NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l intégralité de ce manuel avant d installer ou d utiliser votre nouveau radiateur Le non respect des instructions peut entraîner des dommages matériels des blessures corporelles ou même la mort Une installation incorrecte pourrait annuler votre garantie Co...

Reviews: