background image

USER MANUAL

Pellet Stove

SWEET

3

 7, 7.0 - PERLA

3

 7, 7.0 - CRISTAL

3

 7, 7.0, 7.0 UP

ONE AIRTIGHT - BEAM AIRTIGHT - ACCENT AIRTIGHT

SHARP AIRTIGHT - LEE AIRTIGHT - CHROME 5, 7 AIRTIGHT 

ROUND 5, 7 AIRTIGHT - SOUND

3

 5UP, 7UP

EN

©2022 CADEL srl  |  All rights reserved - Tutti i diritti riservati

new

Summary of Contents for Cristal 7 Up

Page 1: ...T3 7 7 0 PERLA3 7 7 0 CRISTAL3 7 7 0 7 0 UP ONE AIRTIGHT BEAM AIRTIGHT ACCENT AIRTIGHT SHARP AIRTIGHT LEE AIRTIGHT CHROME 5 7 AIRTIGHT ROUND 5 7 AIRTIGHT SOUND3 5UP 7UP EN 2022CADELsrl Allrightsreserv...

Page 2: ...FEATURE SEESECTIONXSETTINGSMENU A PAG 13 20 8 17 PELLETS RECIPE SEE SECTION H SETTINGS MENU A PAG 13 21 8 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 13 21 8 19 CHIMNEY SWEEP FUNCTION FOR...

Page 3: ...an request another copy from the localTechnical Dept or download it directly from the company s website Alllocalregulations includingthosereferringtonationalandEuropeanstandards mustbeobservedwheninst...

Page 4: ...val between routine maintenance operations according to the operating condition of the product We furthermore point out that these operating conditions increase the risk of premature wear of the produ...

Page 5: ...the floor is made of combustible material we recommend using a protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles during cleaning The el...

Page 6: ...tisswitchedonforthefirsttime itisnormalforittoemitsmokeduetothepaintheatingupforthefirsttime Therefore make sure the room it is installed in is well ventilated Periodically check and empty the inspect...

Page 7: ...customer must have the guarantee certificate and present it with the proof of purchase document to theTechnical Assistance Office Theguaranteedoesnotcovermalfunctionsand ordamagetotheappliancethataris...

Page 8: ...DISPOSAL OF MATERIALS 6 1 WARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT The owner is the sole party responsible for demolishing and disposing of the product This must be performed in compliance wit...

Page 9: ...Wastedisposal Thissymbol whichisusedontheproduct batteries accumulatorsoronthepackagingordocuments meansthatattheendofits useful life this product the batteries and the accumulators included must not...

Page 10: ...ECTIVE SHEET LABELS POLYETHYLENE LD PE 04 SORTED waste collection PLASTIC Check the instructions of the com petent body POLYSTYRENE FOAM PEANUTS POLYSTYRENE PS 6 SORTED waste collection PLASTIC Check...

Page 11: ...g com it documenti 7 2 NAVEL STAND ALONE OPTIONAL Procedureifonlyvalidformodelswith NAVELSTANDALONEWi Fitechnology ATTENTION InstallationmustONLYbecarriedoutbyspecialisedpersonnel The manufacturer wil...

Page 12: ...After 2 hours the smell of paint and smoke will disappear By using the stove the varnish inside the combustion chamber could be subjected to alterations This occurrence can be attri butedtodifferentre...

Page 13: ...items that are accessed are Time and Date Timer Sleep only with the stove on Settings Info Date and time setting To set the date and time act as follows Press the menu button Select Time and Date Sele...

Page 14: ...ing the arrows Press menu to confirm Select On with the keys Press menu to confirm and esc to exit c Screw Loading To select Screw loading only when the boiler is switched off act as follows Press the...

Page 15: ...Scroll to Pellet Recipe using the arrows Press menu to confirm Modify the with the keys Press menu to confirm and esc to exit i Smoke Fan rpm To change the parameter act as follows Press the menu but...

Page 16: ...operating mode and shows the selected heat output the ambient temperature and the big flame see Fig 11 If the ambient temperature value exceeds the limit set on the button panel in the temperature set...

Page 17: ...ress menu to access the selected option Modify with the keys Press menu to confirm and esc to exit Set Room T this function allows setting the desired temperature in the room where the stove is instal...

Page 18: ...tionofthetimer There are sixTIMER programmes for each one the user can decide the start up and shutdown time as well as the day of the week in which it is active Whenoneormoreprogrammesareactive thepa...

Page 19: ...at the time set on the active timer 8 14 AUTO ECO MODE SEE SECTION F G SETTINGS MENU A PAG 13 To activate the Auto Eco mode and adjust the time refer SETTINGS MENU a pag 13 Thepossibilitytoadjustthe t...

Page 20: ...ainly depends on the flue it is connected to Once it is connected it is equally important to perform proper adjustment of combustion parameters The Easy Set feature makes it possible to adjust combust...

Page 21: ...se with respect to the default setting 15 15 increase with respect to the default setting 8 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 13 Changestobemadewiththesupportoftheauthorisedtech...

Page 22: ...r pellets currently available on the European market guarantee that the fuel complies with class A1 A2accordingtoISO17225 2 Thesecertificationsinclude forexample ENPlus DINplus NormM7135 andspecifical...

Page 23: ...ding system stops when the tank door is opened Before closing the lid make sure there are no pellets below the gasket Pellets deteriorate the gasket and eliminateitsairtightsealing vediFig 27 10 VENTI...

Page 24: ...aust Significant negative wind clogged fume passages open pellet loading tank open fire door or worn broken gaskets see SMOKE RPMVARIATION User Manual 12 2 SMOKE TEMPERATURE PROBE Detects the temperat...

Page 25: ...M SOLUTION A01 The fire does not ignite Check whether the brazier is clean level of pellets in the hopper Check pellet level in the tank Check that the burning pot is correctly positioned in its case...

Page 26: ...rationsmustbeplannedintimewithyourAutorizedTechnicalAssistanceService After a long ineffective time before turning on the stove check if there are obstructions in the fume exhaust If the stove had bee...

Page 27: ...dinametalcontainerwithasealedlidandthiscontainermustnevergetintouchwithcombu stible materials for example put on a wooden floor as the inner ash keeps the embers firing for a long time Only when the e...

Page 28: ...ing them in evidence 13 9 GASKET REPLACEMENT Incaseofdeteriorationoffiredoor hopperorfumechambergaskets itisnecessary toreplacethembyanautorizedtechnicianin order to guarantee the good running of the...

Page 29: ...becarriedout withascheduledservicecontract Thisoperationconsistsofavisual andfunctionalinspectionoftheinternalcomponents Asummaryofthechecksand ormaintenanceoperationsthatareessential for the correct...

Page 30: ...n fire door or open pellet door Close fire door and pellet door and check that there are no pellet grains at the gasket level Clogged stove Fume chamber cleaning Auger blocked by a foreign object for...

Page 31: ...Faulty fume tempe rature probe Replace the fume probe Faulty mother board Replace the mother board Ash remains along the stove Faulty or out of order door gaskets Replace the gaskets Not sealed fume...

Page 32: ...l 13 O2 238 mg Nm3 NOx al 13 O2 140 mg Nm3 Heat output Nominal heat output Pnom 7 kW Minimum heat output indicative Pmin 2 5 kW Useful efficiency NCV as received Useful efficiency at nominal heat outp...

Page 33: ...mg Nm3 Heat output Nominal heat output Pnom 7 kW Minimum heat output indicative Pmin 2 5 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficiency at m...

Page 34: ...mg Nm3 Heat output Nominal heat output Pnom 7 kW Minimum heat output indicative Pmin 2 5 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficiency at m...

Page 35: ...mg Nm3 Heat output Nominal heat output Pnom 5 5 kW Minimum heat output indicative Pmin 2 5 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficiency at...

Page 36: ...minal heat output Pnom 5 5 kW Minimum heat output indicative Pmin 2 5 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficiency at minimum heat output i...

Page 37: ...minal heat output Pnom 7 kW Minimum heat output indicative Pmin 2 5 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficiency at minimum heat output ind...

Page 38: ...NOTE...

Page 39: ...NOTE...

Page 40: ...CADEL srl 31025 S Lucia di Piave TV Via Foresto sud 7 Italy Tel 39 0438 738669 Fax 39 0438 73343 www cadelsrl com www free point it www pegasoheating com Rev 01 2022...

Reviews: