background image

1

Fire

Fire

Fire

Fire

Installing / Service Company 

Monitoring Station  

SPECIAL CODES

Master Code

                                                   

Duress Code

 

AUXILIARY CODES

"Quick Arm"                "Chime"                         08 

02                                                                     09 

03                                                                     10 

04                                                                     11 

05                                                                     12 

06                                                                     13 

07                                                                     14 

SYSTEM NOTES

Exit Delay Time                                        Secondary Exit Delay Time 

Entry Delay Time                                      Secondary Entry Delay Time 

Fire Alarm Sound (check one)                

 

9

 Steady Siren         

 

9

 Pulsing Bell 

Burglar Alarm Sound (check one)           

 

9

 Yelp Siren           

  

9

 Steady Bell

ZONE DESCRIPTIONS  -            CHECK FIRE ZONES

 

U

ZONE 1 

ZONE 2 

ZONE 3 

ZONE 4 

ZONE 5 

ZONE 6 

Summary of Contents for RANGER 7600

Page 1: ...hime 08 02 09 03 10 04 11 05 12 06 13 07 14 SYSTEM NOTES Exit Delay Time Secondary Exit Delay Time Entry Delay Time Secondary Entry Delay Time Fire Alarm Sound check one 9 Steady Siren 9 Pulsing Bell Burglar Alarm Sound check one 9 Yelp Siren 9 Steady Bell ZONE DESCRIPTIONS CHECK FIRE ZONES U ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ...

Page 2: ...TAIN WITH THIS SYSTEM RELATES SPECIFICALLY WITH TWO MAJOR FACTORS 1 The quantity quality and placement of security devices attached to this system 2 The knowledge you have of the security system and how that knowledge is utilized in a weekly test of the complete system YOU SHOULD BE AWARE OF THE FOLLOWING FACTS WHEN PREPARING A SAFETY SECURITY PLAN FOR YOUR HOME BUSINESS 1 Your security system is ...

Page 3: ...time noted on page 1 If you choose to stay within the protected area insure that all interior zones which may be tripped by your movement are bypassed HOW TO DISARM YOUR SECURITY SYSTEM When you enter the protected area through one of the designated entry exit doors the keypad control will sound a continuous tone beep for the duration of the entry delay time or until you enter a valid code After a...

Page 4: ...ing company may have programmed the INSTANT option to occur in conjunction with the AUTOMATIC BYPASS feature In this case the INSTANT light and the bypassed ZONE lights will become illuminated at the end of the exit delay If this occurs you still have the ability to turn the INSTANT feature off and or on by pressing the r key GROUP BYPASS OPTION If checked the GROUP BYPASS option has been selected...

Page 5: ...ame time for one second If your system is connected to a monitoring center an emergency report could be sent to that center These keys should only be pressed in an emergency situation requiring response by fire department personnel KEYPAD ACTIVATED AUXILIARY ALARM If checked this feature has been selected by your installing company If so you can activate the auxiliary alarm by pressing the four 4 ...

Page 6: ...de is 1 2 3 4 and you want to change it to 5 3 4 2 the programming sequence would be as follows Press r 1 this enters programming for user 1 Then enter the current Master Code of 1 2 3 4 Press r 1 to verify user 1 programming Now enter your new Master Code of 5 3 4 2 and exit programming with r 1 The entire sequence would consist of pressing 17 keys as follows r 1 1 2 3 4 r 1 5 3 4 2 r 1 PROGRAMMI...

Page 7: ...OL TONES BEEPS A sounder is built into the keypad and may sound for any of the following reasons Beeps for all keypresses Sounds a continuous tone during the Entry delay time Pulses when a dayzone is violated while the system is disarmed Pulses when a FIRE zone has a trouble condition Pulses when the armed status changes and the AC power is off Beeps 3 times for trying to arm with the READY light ...

Page 8: ...dures In a home sleep with bedroom door closed this will increase your escape time If you suspect fire test the door for heat If you think it is safe brace your shoulder against the door and open it cautiously Be ready to slam the door if smoke or heat rush in Practice escaping to the outdoors and meeting in an assigned spot Call the Fire Department from a neighbor s phone NOTE After the installat...

Page 9: ...9 SYSTEM NOTES ...

Page 10: ...7600 USER S MANUAL 7600UE98 REV E 02 10 98 ...

Reviews: