17.12.2012 

Operating Instructions 

Busch-Timer

®

 

 

 

 

Pos: 2 /#N eustruktur #/Online-Dokumentation (+KN X)/Titelbl ätter/Ti mer/Titelbl att 6455 Jal ousie @ 26\mod_1343372636549_15.docx @ 225649 @  @ 1 

 

Comfort timer control element 

for blind control 

6455 

 

 

 

 

  

 

  

 

 

=== Ende der Liste für T extmar ke Cover ===  

 

Summary of Contents for Busch-Timer 6455

Page 1: ...nstructions Busch Timer Pos 2 N eustruktur Online Dokumentation KN X Titelbl ätter Ti mer Titelbl att 6455 Jal ousie 26 mod_1343372636549_15 docx 225649 1 Comfort timer control element for blind control 6455 Ende der Liste für Textmar ke Cover ...

Page 2: ...tructure 9 5 6 Adjusting the device 11 5 6 1 Selecting languages 11 5 6 2 Setting date and time 12 5 6 3 RESET resetting the device 13 5 7 Operating modes 14 5 7 1 Deleting switching times 15 5 8 Setting switching times 16 5 8 1 BLOCK programming 16 5 8 2 ASTRO function 18 5 8 3 Individual switching times 20 5 8 4 Additional switching times 21 5 9 Calling up special functions 22 5 9 1 Activating a...

Page 3: ... e D okumente 1 Ebene U Z U mwelt 18 mod_1302614158967_15 docx 103383 1 1 3 Environment Pos 11 Neustr uktur Online Dokumentati on KN X Sicherheitshinweise und Hinweise Für alle Dokumente Hinweise U mwelt Hi nweis U mwelt Hi nweis El ektr ogeräte 18 mod_1302763973434_15 docx 103500 1 Consider the protection of the environment Used electric and electronic devices must not be disposed of with domesti...

Page 4: ...5 Alternative 6411 U S 101 6435 6455 Pos 18 Neustr uktur Online Dokumentati on KN X Überschriften Für all e D okumente 2 Ebene A F Funkti ons und Ausstattungsmer kmal e 23 mod_1336557630140_15 docx 209136 22 1 4 2 Features of function and equipment Pos 19 Neustr uktur Online Dokumentati on KN X Aufbau und Funkti on Ti mer Funkti onen 6455 Jalousie 26 mod_1343660942120_15 docx 226183 23133 1 With a...

Page 5: ...me If the brightness drops below the set value for several minutes the blind travels up again This means that the function remains independent of whether the brightness sensor is overridden or not Fig 1 Connected brightness sensor The sensor can be attached at any position on the window pane Pos 23 Neustr uktur Online Dokumentati on KN X Überschriften Für all e D okumente 2 Ebene G L Glasbruchmeld...

Page 6: ...for about 14 hours After this the time and date have to be reprogrammed All other data remain saved The operating element can be removed from the flush mounting insert for approximately 20 minutes and adjusted separately A total of 4 switching times per day can be set switching times plus additional switching times The system changes automatically between winter and summer time If the display is o...

Page 7: ...ati on KN X Überschriften Für all e D okumente 2 Ebene M O M anuelle Bedi enung 28 mod_1346940429935_15 docx 230994 22222 1 5 3 Manual operation Pos 33 Neustr uktur Online Dokumentati on KN X Bedi enung Ti mer M anuelle Bedi enung 6455 Jal ousie 28 mod_1346940513035_15 docx 231007 32222332 1 Manual operation is always possible You can control the blind manually as follows Button Function Actuation...

Page 8: ...333 1 Fig 4 Display with symbols No Function 1 Automatic operating mode 2 Manual operating mode 3 Holiday operating mode 4 Mains power failure 5 Info line date 6 Venetian blind control UP DOWN 7 Current weekday 8 Time switching time 9 Sun protection twilight function Only in connection with 6411 U S 101 and sensor 10 Current actual value of the sensor Note If the text is too long for the info line...

Page 9: ...Sun Down Astro Set a time shift of 90 minutes The astro switching times are pre programmed however with the shift the switching time can be adapted to the regional conditions Mon Fri UP Time shift Mon Fri Down Time shift Sat Sun Up Time shift Sat Sun Down Time shift Individual Set the switching times for moving the blind up or down for each weekday independent of each other Mon UP Mon Down Tue Up ...

Page 10: ...at which the blind travels DOWN Twilight 0 9 Additional switching times Mon UP The menu is only displayed when the additional switching times have been activated beforehand under Special functions Set additional switching times for moving the blind up or down for each weekday independent of each other Mon Down Tue Up Tue Down Pos 40 Neustr uktur Online Dokumentati on KN X Steuer modul e Online Dok...

Page 11: ... 6 1 Selecting languages Pos 44 Neustr uktur Online Dokumentati on KN X Bedi enung Ti mer Einstellungen Sprache 6455_6456 26 mod_1343377850120_15 docx 225705 32223222 1 The language is set via the country selection and the astro time is automatically assigned The current location country of the timer must be selected because of the different time zones Note The astro function daily adjusts the swi...

Page 12: ...et year flashes 2011 Set the year via the arrow buttons Month Confirm your entry with the OK button You simultaneously switch to the next menu item Month The preset month flashes 6 01 Set the month via the arrow buttons Day Confirm your entry with the OK button You simultaneously switch to the next menu item Day The preset day flashes 6 01 Set the day via the arrow buttons Hour Confirm your entry ...

Page 13: ...5331 111111111111111111111111111111111111111111111111111111111111111112221212212221112212211111121221112212222121111222112111222221132121112212221221111111122222222222222222222222222222221 4 Fig 7 Reset 1 Remove the cover and press the reset button 2 Replace the cover 3 Then again set the language the date and the time see section 5 6 Note After a reset the settings of the language date and time a...

Page 14: ...are not carried out General actuation You can control the blind as follows UP Touching the top surface The blind travels to the top end position or Hold the top surface The blind travels up as long as the button is pressed DOWN Touch the bottom surface The blind travels to the bottom end position or Hold the bottom surface The blind travels down as long as the button is pressed A brief actuation w...

Page 15: ... the next page Deleting all switching times Fig 9 Delete function 1 Press all 4 buttons simultaneously or the entire operating surface for more than 5 seconds 2 Confirm the enquiry with the OK button All set switching times will now be deleted The date time and language settings remain saved Deleting the current switching time in the setting mode Fig 10 Delete function of current value Individual ...

Page 16: ... Bedi enung Ti mer Block Pr ogrammi erung Allgemein 6455 26 mod_1343393105543_15 docx 225816 1 So that the switching times need not be entered again for each individual day the BLOCK programming function is available This means that the switching times are entered once for block Mon Fri and once more for block Sat Sun Note Within each block the same switching times apply to each day If the switchi...

Page 17: ...sly switch to the next menu item Mon Fri DOWN The preset down time flashes 20 30 Set the desired down time via the arrow buttons In this example the down time has been set at 20 30 Sat Sun UP 08 00 Press the OK button again The preset up time flashes 08 30 Set the desired up time via the arrow buttons In this example the up time has been set at 8 30 Sat Sun down 21 00 Confirm your entry with the O...

Page 18: ...le in addition to the astro time With the time shift the astro time can be adapted to the regional conditions Pos 67 Neustr uktur Online Dokumentati on KN X Bedi enung Ti mer Einstellungen Astro Funktion 6455 Jal ousi e 28 mod_1347000021333_15 docx 231791 12 1 Fig 12 Menu item Astro Sequence of operating steps Button Display Entry Comments Switching times Press the menu button to switch to the set...

Page 19: ...uttons The up time flashes The astro time for sunrise is fixed and cannot be changed Time shift Confirm the time with the OK button You simultaneously switch to the next menu item Time shift 0 20 Set the time shift for the specified astro time via the arrow buttons so that the switching time is adapted to the regional conditions In this example the up time has been pushed back 20 minutes No shift ...

Page 20: ...item Monday UP The display flashes MONday UP 7 00 Press one of the arrow buttons The suggested up time flashes 7 20 Change the time via the arrow buttons In this example the up time has been set at 7 20 No switching time will be set if the flashing display is confirmed MONday Down Confirm your entry with the OK button You simultaneously switch to the next menu item Monday DOWN The display flashes ...

Page 21: ...ng mode Additional switching times Select menu item Additional switching times via the arrow buttons MONday UP You simultaneously switch to the next menu item Monday UP The display flashes MOntag AUF 15 00 Press one of the arrow buttons The suggested up time flashes 15 00 Change the time via the arrow buttons In this example the up time of 15 00 has been taken over No switching time will be set if...

Page 22: ...Zusatz Schal tzei ten 6455 26 mod_1343815841166_15 docx 226431 13322222222 1 To enable additional switching times to be entered menu item Additional switching times must first be activated See the following description Fig 15 Menu item Special functions Additional switching times Sequence of operating steps Button Display Entry Comments Switching times Press the menu button to switch to the settin...

Page 23: ...ction Return pulse you can let the blind move up from the bottom end position until the ventilation slots are open With this function the blind is after closing DOWN command moved in the UP direction for the set time The adjustment range lies between 0 and 255 Setting Meaning 0 No return pulse 255 Maximum duration corresponds to around 30 seconds The return pulse is executed only if the blind was ...

Page 24: ...ng times has been activated Additional switching times for return pulse O 00 Confirm your entry with the OK button You simultaneously switch to the next menu item Twilight return pulse The display flashes 1 00 Set a return pulse from 0 to 255 via the arrow buttons In this example a return pulse of 100 has been set The following menu items are displayed only if a brightness sensor has been connecte...

Page 25: ...Jalousie 26 mod_1343816034665_15 docx 226457 22 1 With the duration of downward movement setting the movement to a freely selectable intermediate position between the upper and lower setting is possible If necessary the duration can be reduced by up to 5 seconds This position can only be moved to from the top end position The preset DOWN time of 3 minutes can be especially reduced for the followin...

Page 26: ... down movement The preset duration of down movement flashes 2 30 Set the duration of down movement via the arrow buttons In this example a duration of down movement of 2 minute and 30 seconds has been set The following menu items are displayed only if a brightness sensor has been connected Duration of down movement at twilight 3 00 Confirm your entry with the OK button You simultaneously switch to...

Page 27: ...itional switching times Press the OK button Menu item Additional switching times is displayed Astro Select menu Astro via the arrow buttons Astro Blocking time Up Confirm your selection with the OK button You simultaneously switch to the next menu item Astro blocking time UP The display flashes 6 00 Set the earliest time via the arrow buttons from which the blind is to be moved up In this example ...

Page 28: ...de Sensor Select menu Sensor via the arrow buttons Sun protection Press the OK button Menu item Sun protection is displayed Press the OK button again The display flashes 6 Set a brightness value 0 to 9 via the arrow buttons at which the blind moves DOWN For setting the function is OFF In this example the value 6 has been set Sensor Confirm your entry with the OK button You simultaneously switch to...

Page 29: ... moves DOWN For setting the function is OFF In this example the value 5 has been set Sensor Confirm your entry with the OK button You simultaneously switch to menu Sensor Press the menu button to switch to the operating mode The bar in the display indicates the currently set brightness value The twilight function closes the blind if the set brightness value falls short for more than 90 seconds The...

Page 30: ...ltage failure or the control element unplugged Prerequisite however is that the timer was charged previously for several hours The flashing plug symbol see magnification shows that the mains voltage supply to the timer is deactivated The time continues to run in the background but is not displayed to save energy If the timer is again supplied by the mains network within a period of 14 hours the cu...

Page 31: ..._15 docx 83019 2212222211111112 1 6 Technical data Pos 96 Neustr uktur Online Dokumentati on KN X Technische Daten Ti mer Technische Daten 6455_6456 26 mod_1343660576925_15 docx 226154 22122 1 General Power reserve 4 h Protection type IP 20 Ambient temperature 0 35 C Pos 97 Neustr uktur Online Dokumentati on KN X Steuer modul e Online Dokumentation Für alle Dokumente Seitenumbruch 9 mod_1268898668...

Page 32: ...nstalled and electrically connected beforehand The electrical connection is described in the separate instructions of the flush mounted insert Pos 101 N eustruktur Onli ne D okumentation KNX M ontag e Ti mer Montage 6455_6456 26 mod_1343717080218_15 docx 226218 2222212 1 1 Pull the attachment off If the device is already mounted or assembled pull off the attachment from the flush mounted insert wi...

Page 33: ...0 2351 956 1700 Notice We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations conta...