Operation Instructions 

DACT Keypad 
Programmer 

 

FMR-DACT-KEYPAD 

 

Summary of Contents for FMR-DACT-KEYPAD

Page 1: ...EN Operation Instructions DACT Keypad Programmer FMR DACT KEYPAD ...

Page 2: ...tain the FMR DACT KEYPAD according to these instructions NFPA 72 local codes and the Authority Having Jurisdiction AHJ Bosch is not responsible for improperly installed tested or maintained devices 1 0 Description The FMR DACT KEYPAD Figure 1 is a four wire alphanumeric liquid crystal display LCD keypad used as a programming device for the DS9602 D9068 and FPT DACT Fire Communicators Figure 1 FMR ...

Page 3: ...R DACT KEYPAD terminal strip as shown in Figure 2 4 Place the FMR DACT KEYPAD on its base 5 While feeding the excess wiring out of the back of the base press straight down on the cover until it latches on Figure 2 Wiring the FMR DACT KEYPAD Terminal Strip 12 VDC Com Data In Data Out LINE 1 LINE 2 A B 1 2 3 4 5 NC C NO SYS TROUBLE HEARTBEAT KEYPAD 1 2 3 4 5 6 7 1 DACT Fire Communicator 2 FMR DACT K...

Page 4: ...he base Figure 3 Installing the Instruction Label and Slide 1 2 3 2 1 Back of the FMR DACT KEYPAD 2 Label 3 Slide Note The label on the slide has writing on the reverse side 5 0 Setting the Address The FMR DACT KEYPAD must have an address set within its address pins Select the address 1 to 15 by placing the shorting jumpers over the address pins as shown in Figure 4 Figure 4 Setting the Address 1 ...

Page 5: ...e feature or character position Figure 6 5 Disable key Returns to the previous programmable feature or character position Figure 6 6 Test key Enters Test Mode Pressing Test when entering a telephone number accesses three telephone control code options Refer to the D9068 P N 45386 DS9602 P N 45387 or FPT DACT Operation Installation Guide P N F01U002505 7 History key Enters History Mode Refer to the...

Page 6: ...5386 DS9602 P N 45387 or FPT DACT Operation and Installation Guide P N F01U002505 2 If there is no FMR DACT KEYPAD activity for 3 min it disables The FMR DACT KEYPAD buzzer sounds and a System Fault message appears 3 Disconnect the FMR DACT KEYPAD from the DACT as described in the D9068 P N 45386 DS9602 P N 45387 or FPT DACT Operation and Installation Guide P N F01U002505 8 0 Troubleshooting Table...

Page 7: ...ge 12 VDC Standby Current 100 mA 75 mA for battery calculation Alarm Current 100 mA 75 mA for battery calculation Operating Temperature 32 F to 120 F 0 C to 49 C Relative Humidity 5 to 85 non condensing 86 F 30 C Dimensions H x W x D 5 in x 6 in x 1 in 12 cm x 16 cm x 3 cm Listings and Approvals UL864 California State Fire Marshall CSFM Environmental Use indoor dry ...

Page 8: ... 2006 Bosch Security Systems Inc F01U002307C Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 9199 Customer Service 800 289 0096 Technical Support 888 886 6189 ...