Summary of Contents for VMBKP

Page 1: ......

Page 2: ...vanced 9 ALM O P Alarm Output 9 DUR O P Duress Output 9 O P 1 INH User Group 1 Inhibit Control Input Normally Open 9 EG IN Egress Input 9 GND Common ground 9 DOOR SENS Door Position Sensing Input Norm...

Page 3: ...de Location 02 18 Examples 19 Operation and functions of the Super User Code 19 Common user codes for User Groups 1 2 locations 03 04 20 Example 20 User codes cards for User Groups 1 2 locations 10 20...

Page 4: ...ing beep and alarm location 90 33 Examples 34 Exit programming mode 35 Programming summary chart 36 Application hints for the auxiliary terminals 40 Door sens 40 Door Auto Relock 40 Door Forced open A...

Page 5: ...an EM Card or a combination of both See Security level of the operation media on p 13 for more details In the Velbus configuration software VelbusLink the keypad appears with two input channels User...

Page 6: ...Tamper alarm When the keypad s cover is removed from its base the Tamper channel becomes pressed until the cover is placed back and actions can be executed e g locking the keypad starting a siren swi...

Page 7: ...ding additional functionality using inputs outputs that are not connected to the Velbus system if needed these can be connected using Velbus input and output modules o input for sensing the door posit...

Page 8: ...0 5 1 5mm mounting screws wall plugs and 2 RFID cards included operating conditions 20 to 70 C protection rating IP65 delays for code entry and card reading o 10 seconds max delay for next digit entry...

Page 9: ...can be used e g to trigger an alarm zone of a security system or turn on a buzzer to notify a guard O P 1 INH User Group 1 Inhibit Control Input Normally Open A Normally Open N O sensing input point f...

Page 10: ...n be stopped with a User Code or card for User Group 1 at any time See Door forced open warning location 80 on p 31 for more information Door Propped up Warning The keypad generates propped up warning...

Page 11: ...STATUS TONES AMBER LED SIGNAL In Programming Mode none ON Successful Key Entry 1 beep 1 Flash Successful Code Card Entry 2 beeps 2 Flashes Unsuccessful Code Card Entry 5 beeps 5 Flashes Power Up Delay...

Page 12: ...backlit in standby It turns to fully backlit when a key button is pressed then back to dimly backlit 10 seconds after the last key button is pressed 2 Auto Back lit The backlit is OFF in standby It tu...

Page 13: ...cards or it can be unique with one code for one card NOTE The keypad will reject repeated use of prime cards or prime codes while programming and indicate this with a long beep Security level of the...

Page 14: ...n mode can also report a Duress Alarm close the DUR O P when the Duress Code is entered instead of the unique Secondary User Code This is useful to trigger a silent alarm when the user is forced to op...

Page 15: ...us eu PN VMBKP ed1 A4 List of user information To avoid confusion and for programming convenience we suggest making a list of the user information and keeping this for future reference See the VMBKP Q...

Page 16: ...elay it can be set in programming mode by entering the Master Code and validating it with Master code Validation 0 0 0 0 For the owner s convenience in programming the first time a Master Code 0 0 0 0...

Page 17: ...uring refreshing c The keypad is back to its default value after refreshing Reprogramming of the desired values is necessary Default values after refreshing LOCATION PARAMETER DEFAULT FUNCTIONS VALUES...

Page 18: ...not be changed in any way Master code Location 01 Location Master code Validation 0 1 4 to 8 digits 1 Location Enter Location 0 1 2 Master code The Master Code is the authorization code for setting t...

Page 19: ...o enable the following optional functions controlling User Group 1 for user convenience or security enhancement The Super User Code and Egress Button are excluded from any hardware inhibition3 and loc...

Page 20: ...peration Mode 4 on p 20 and Security level of the operation media on p 13 for more information NOTE a Common User Code alone can NOT operate the User Group channels directly Locations Common user code...

Page 21: ...king in the same department b The Common User Codes for User Groups 1 and 2 have first been programmed at Locations 03 04 respectively cfr p 20 It is not necessary to enter the Common User Code again...

Page 22: ...n programming mode 1 0 3 0 0 2 Read Card 2 4 6 8 0 a b c d e f a The card is programmed for operating User Group 1 channel b The operation mode is Card Secondary User Code c Use ID number 002 in Group...

Page 23: ...st Card 1 0 5 User ID a b c d a Enter the User Group that the User ID belongs to 1 0 for Group 1 2 0 for Group 2 b Enter 5 the Command Code for making a deletion c Enter the User ID d Press the key A...

Page 24: ...roup channel 1 only location 40 The Visitor Codes are temporary user codes for User Group 1 channel They can be programmed as One Time Codes or Codes with Time Limit One Time Visitor Codes will be cle...

Page 25: ...number 1 2 6 8 for User Group 1 4 0 0 1 0 0 1 2 6 8 1 2 3 4 5 1 Visitor Code programming 2 Visitor ID 3 One time code 4 The visitor code 5 Entry confirmation Example 2 Set a Visitor Code with the numb...

Page 26: ...Please see the Programming example below for details 3 Duress Codes 50 Duress Codes can be programmed for User Group 1 and 10 for User Group 2 When a new Duress Code is entered for an existing Duress...

Page 27: ...in location 41 are cleared Operation and function of the Duress Code The Duress Code has a double action when it is entered It activates the Duress Output8 for duress alarm and at the same time activ...

Page 28: ...perating User Group 1 channel 3 Confirm it with the key User Group 1 channel activates in a normal way and the Duress Output also activates to report Duress Event to an alarm system if connected NOTE...

Page 29: ...irms the entry User code entry mode Auto or manual location 70 Location Entry modes Validation 7 0 1 or 2 1 2 3 1 Location Enter location 7 0 2 User Code entry modes Two modes 1 and 2 are available fo...

Page 30: ...he Channel State Announcer emits a sound signal representing the status of the User Group channels The Channel State Announcer signal is also OFF while the Notification Tone in Location 71 is set to O...

Page 31: ...ps and alarm will last as long as the selected duration they can be stopped at any moment by using a valid a User Code Card in User Group 1 3 Validation Press the key once A double beep confirms the e...

Page 32: ...normal use the Egress button does not need to be configured the settings can remain on their default values Use cases for an Egress Button and optional delays and alarms Hospital Some of the patients...

Page 33: ...ypad beeps during the delay while people are waiting for the door to open 3 Pulse Mode with Warning Beeps Alarm In this mode User Group 1 is activated after a short press on the Egress button The keyp...

Page 34: ...nel will NOT be activated For safety reasons it is advised to put a sticker next to the Egress button explaining how to open the door if Holding Mode is enabled Example A sticker for an egress button...

Page 35: ...pressed during the delay 4 Entry confirmation Example 3 Set Egress Button in Pulse Mode without delay default setting 9 0 1 0 1 2 3 4 1 Egress function programming 2 Pulse mode without delay 3 Instant...

Page 36: ...mmon User Code for User Group 2 0 4 COMMON USER CODE 1 NIL 10 User Codes Cards for User Group 1 CODE 1 MEDIA 1 EM Card 2 Private User Code 3 EM Card Secondary User Code 4 EM Card Common User Code 5 De...

Page 37: ...ODE 4 8 digits 4 1 CODE ID DURESS CODE NIL 60 Personal Safety Lock Up LOCK UP CODE 1 after 10 trials lock up 60s 2 after 10 trials activate duress output 5 10 after 5 10 trials lock up 15 minutes 00 n...

Page 38: ...p warning duration MODE TIME 0 OFF 1 999 duration of warning in seconds 8 1 MODE TIME 0 OFF 90 Egress mode delay warning beep and alarm CODE 1 FUNCTION MODE 1 Pulse mode no warning 2 Pulse mode with w...

Page 39: ...H CODE Refresh the system and set all parameters back to default values except Master Code 9 9 9 9 All programmed data are cleared all values are reset to default values except the Master Code 2 8 2 8...

Page 40: ...to prevent tailgate entries This function is automatically active and needs no additional configuration Door Forced open Alarm The keypad will emit warning beeps and close the ALM O P14 instantly if...

Page 41: ...er the Egress Delay You may use it for instance to turn ON a LED lamp and or a small buzzer to notify a guard or connect it to a 24 hour Normally Open protection zone of an alarm system See Door force...

Page 42: ...s Code is entered It can for instance be used to turn ON a LED lamp and or a small buzzer to notify a guard or it can be connected to a 24 hour Normally Open protection zone of an alarm system See Dur...

Page 43: ...ctive Transistor open collector output An open collector output is equivalent to a Normally Open N O contact referring to ground similar to a relay contact referring to ground The transistor is normal...

Page 44: ...VMBKP 44 Velbus Legen Heirweg 33 BE 9890 Gavere Belgium tel 32 9 384 36 11 e mail info velbus eu www velbus eu PN VMBKP ed1 A4...