INSTALLER

DFWM-12-FR & DFWM-19-FR Fountains are among the easiest to install 
Fountains on the market today. To assure you install these models easily and 
correctly, 

PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING 

THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH 
PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES.

 

After installation, leave these instructions with the Fountain for future reference.

This Freeze Resistant Fountain is shipped in two separate cartons. The second 
carton contains the Freeze Resistant Package that is installed on an interior 
heated wall. Refer to the Freeze Resistant Package for the rough-in dimensions 
for installation.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

IMPORTANT

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO 
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY 
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO 
A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE 
IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER 
MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE 
OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.

DFWM-12-FR 

DFWM-19-FR

Freeze Resistant

 

Wall Mount Stone Fountain

Owner’s Manual

2302 Yellow Smoke Road
PO Box 369 
Denison, IA  51442 
800.325.2380
www.bohlmann.com

Summary of Contents for DFWM-12-FR

Page 1: ... wall Refer to the Freeze Resistant Package for the rough in dimensions for installation IMPORTANT ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON IMPORTANT THEGROUNDINGOFELECTRICALEQUIPMENTSUCHASTELEPHONE COMPUTERS ETC TO WATERLINESISACOMMONPROCEDURE THISGROUNDINGMAYBEINTHEBUILDINGORMAY OCCURAWAYFROMTHEBUILDING THISGROUNDINGCANCAUSEELECTRICALFEEDBACKINTO AFOUNTAIN CREATINGANELECTROLYS...

Page 2: ...e stop not provided and make water supply connection from the stop to the strainer in the freeze resistant box DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O RINGS MAY RESULT Connect fountain water line to freeze resistant box see box instructions Replace the bottom cover 1 2 3 4 5 6 7 8 GENERAL INSTALL TIPS 7 16 11 mm MOUNTING HOLE 3 12 7 8 327 mm 3 76 mm 1 3 4 44 mm WASTE LINE...

Page 3: ...rom the fitting relieve water pressure push in on the gray collar while pulling on the tubing see figure 4 1 4 O D TUBE WATER INLET TO COOLER 3 8 O D UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY NOTE WATER FLOW DIRECTION BUILDING WATER INLET SERVICE STOP NOT FURNISHED 1 25mm APPROXIMATELY STREAM HEIGHT Stream height is factory set at 45 50 PSI If supply pressure varies greatly from this adjust s...

Page 4: ...TION 1 400942308640 Bubbler Dual Stream 2 100322740560 Bubbler Gasket 3 600985551640 Drain Plug Assy 4 170705042830 Basin Receptor 5 15013C Bubbler Tube Assy 6 100147140560 Drain Gasket 7 55884C Drain Elbow 8 55885C Slip Joint Nut 1 1 4 9 66346C Drain Tube 10 97056C Freeze Resistant Box 3 4 2 5 6 7 8 9 2 1 10 ...

Reviews: