Summary of Contents for SOLARLINK S1K2X

Page 1: ...PLEASE READ THIS MANUAL BEFORE USE AND FOLLOW ITS GUIDANCE ...

Page 2: ...AFETY 4 Earthing 4 IN THE BOX 6 INSTALLATION 7 USING THE EQUIPMENT 8 Suitable solar panels 8 Connection sequence 9 Disconnection sequence 9 TECHNICAL SPECIFICATION 9 TROUBLESHOOTING 11 SUPPORT 12 User Manual R1 0 2 12 ...

Page 3: ...INTRODUCTION The SOLARLINK module allows you to recharge or maintain charge on RESERVOIR or JUNCTION modules using standard solar panels User Manual R1 0 3 12 ...

Page 4: ...truct fan openings Inadequate ventilation may cause permanent damage to the equipment DO NOT move the unit while operating KEEP AWAY from children and pets DO NOT insert foreign objects into any ports or openings of the equipment If necessary only dry powder fire extinguishers are suitable for the product USE ONLY the original cables designed for the equipment Belair Technology SA are not liable f...

Page 5: ...f the belair system Neither the positive or negative pole of the solar panel should be connected to the chassis It is recommended to follow local electrical regulations please consult a local electrician if unsure User Manual R1 0 5 12 ...

Page 6: ...IN THE BOX 1 Belair SOLARLINK 2 DC power cable 3 Rack mounting screws 4 User Manual 5 QC certificate User Manual R1 0 6 12 ...

Page 7: ...INSTALLATION It is recommended to install all belair equipment in suitable 19 inch enclosures User Manual R1 0 7 12 ...

Page 8: ...permissible to use a solar array with a higher power than 700W however the SOLARLINK will limit the power to protect the system belair recommends monocrystalline panels for maximum efficiency for example 4 x Victron Energy SPM042152400 or 2 x Victron Energy SPM043602400 belair recommends panels fitted with MC4 connectors MC4 extension cables will be needed to bring the solar panel connections to t...

Page 9: ...ilst the belair system and connectors are rated for connection under load lifetime of the connectors will be dramatically increased by only manipulating the connections without load The solar panel connectors are industry standard MC4 type for convenience however these connectors are not rated for disconnection under load It is therefore very important to follow the correct sequence when disconnec...

Page 10: ...MODEL SOLARLINK S1K2X SYSTEM VOLTAGE 48V MAXIMUM PV INPUT VOLTAGE 100V DC MAXIMUM CHARGE CURRENT 14A RACK HEIGHT 2U WEIGHT 5KG DIMENSIONS 89mm x 422mm x 203mm User Manual R1 0 10 12 ...

Page 11: ...les Solar LED not lit Possible cause Solution Solar panel voltage too low Not enough panels connected in series Must be 4 x 12V or 2 x 24V Internal failure Contact support belairtechnology com Battery LED not lit Possible cause Solution JUNCTION or RESERVOIR off Turn on JUNCTION or RESERVOIR Internal failure Contact support belairtechnology com User Manual R1 0 11 12 ...

Page 12: ...SUPPORT Contact support belairtechnology com User Manual R1 0 12 12 ...