background image

USER MANUAL

MODEL:B0341WST2H2-V3

WIRELESS WEATHER STATION

(Please Keep the Manual for Maintenance)

Email

[email protected]

Phone

1-833-381-5659

Thank you for choosing BALDR wireless weather station, 
any help needed, please feel free to contact us :

WEB

www.baldr.com

English 
Deutsche 
Français
Italiano
Español

1-19
20-38
39-56
57-74
75-93

Summary of Contents for B0341WST2H2-V3

Page 1: ...p the Manual for Maintenance Email baldrservice baldr com Phone 1 833 381 5659 Thank you for choosing BALDR wireless weather station any help needed please feel free to contact us WEB www baldr com English Deutsche Français Italiano Español 1 19 20 38 39 56 57 74 75 93 ...

Page 2: ......

Page 3: ...ion 2 QUICK SETUP 2 1 Before Start 2 2 Initial Setting 3 MULTIFUNCTIONAL WEATHER STATION 3 4 Channel Modes 3 3 Weather Forecast 3 2 Temperature Humidity Display 3 1 The Working Principle of Weather Station and Sensor 3 5 Alarm Setting 3 6 Backlight 3 7 Low Battery Indication 4 TROUBLESHOOTING 5 PRECAUTIONS 6 WARRANTY 7 FCC STATEMENT 19 ...

Page 4: ...1 1 Package List ITEM NO ITEM NAME FIGURE QTY 1 1 2 3 Main Unit Outdoor Sensor User Manual 1 1 1 PRODUCT OVERVIEW 2 ...

Page 5: ...age 4 Outdoor Sensor Channel 11th 13th page 5 Outdoor Temperature 12th page 6 Outdoor Humidity 12th page 7 Indoor Temperature 12th page 8 Indoor Humidity 12th page 9 Max Min Records of Temperature and Humidity 12th page 10 Low Battery Indicator 16th page 11 Temperature Trend Arrows 12th page 12 Week Language Abbreviation 8th page 1 12 3 5 7 2 4 10 11 6 9 8 ...

Page 6: ...13th page 5 SET C F Button 6th 11th page 6 Hanging Hole 7 Battery Compartment 8 Stand Bracket Temperature Humidity Accuracy Temperature 0 50 32 122 accuracy 1 1 8 Others Ranges accuracy 2 3 6 Humidity 40 80 accuracy 5 Others Ranges accuracy 8 Part 2 Weather Station Main Unit Back 4 1 7 2 3 6 4 5 8 ...

Page 7: ...s Outdoor Sensor To get accurate readings please keep the main unit away from any unusual source of heat or cold and make sure that the outdoor sensor is also protected from direct sunlight rain or the heat it may experience from being mounted on a warm wall or be closed near to a warm wall 2 3 4 1 5 ...

Page 8: ...r Week Language Beep Select C Backlight for 20s Hold Press Hold Button ALARM MEM CH SET C F Time Setting Alarm Goes Off Turn Off Alarm Turn Off Alarm Turn Off Alarm Turn Off Alarm Enter Snooze Mode Press Decrease 1 Increase 1 Decrease Continuously Increase Continuously Confirm and Go to Next Step Exit and Back to Normal Mode Alarm Setting Confirm and Go to Next Step Decrease 1 Increase 1 Decrease ...

Page 9: ...e remote sensor s 4 Inset 2 new AA standard alkaline batteries into the sensor in 3 min The signal flashing indicates that main unit is receiving the outdoor temperature and humidity from sensor The receiving status will last for max 3 minutes The signal will stop flashing after received or 3 minutes later 5 Please allowed the main unit and outdoor sensor at the same position for half an hour or m...

Page 10: ...th D Date Press CH or MEM button to to select M D or D M format Press Set C F button to confirm 6 Month The Month symbol will flash Press CH or MEM button to adjust the value Press Set C F button to confirm 7 Date The Date symbol will flash Press CH or MEM button to adjust the value Press Set C F button to confirm 8 Week Language Abbreviation The Week Language Abbreviation symbol will flash Press ...

Page 11: ...sh the all time setting Then press and hold the Set C F button for 3 4 secs to start setting and Press continuously the Set C F button to confirm until enter the Year setting and set the correct year Please refer to Year Setting The data of weather forecast and outdoor humidity temperature come from outdoor sensors Make sure the outdoor sensor place in proper place Take an example If place the sen...

Page 12: ... 2 5 meters 3 93 8 20 feet vertically 4 You are near the sensor to connect the main unit Avoid thick walls between the units or or strong interference source using same signal frequency 433Ghz such as TVs microwaves computers etc 5 If the main unit disconnects most likely the sensor is too far from the main unit Please place it nearer to the sensor Transmission Range 100m 330ft Open Air The sensor...

Page 13: ...f the main unit by CH1 114S CH2 134S CH3 158S Transmission range 100m 330ft in the open air RF 433Ghz To ensure the successful reception of outdoor temperature and humidity please refer to the setting steps on page 7 3 2 1 Temperature Display Press the SET C F button to select or unit 6 Vertically placement is required Please search BALDR on Youtube to Find the English Setting Video 3 1 The Workin...

Page 14: ...es less than 1 1 8 within one hour or compared with the last reading will display when the reading increase by 1 1 8 within one hour or compared with the last reading will display when the reading decrease by 1 1 8 within one hour or compared with the last reading Indoor temperature range 10 50 14 122 Outdoor temperature range 20 60 4 149 Indoor and outdoor humidity range 1 99 RH Note If the tempe...

Page 15: ... Channel Mode starts with the CH1 CH2 or CH3 Individually showing Single Channel Mode fit for only one sensor s kit which will show only 1 group data of outdoor temperature humidity in fixed channel Weather Icons 3 3 Weather Forecast 3 4 Channel Modes 3 4 1 Single Channel Model Please make sure the main unit and outdoor sensor are in the same channel Note Partly Cloudy is default after power on Ci...

Page 16: ... the CH button 2 times to enter the Single Channel Mode 3 When the sensor s channel is CH3 need to set up the main unit s channel to CH3 Press the CH button 3 times to enter the Single Channel Mode 1 Press and hold ALARM button for 3 4 secs to start 2 The Hour symbol begins to flash Press CH or MEM button to set up Hour Press ALARM button to confirm 3 The Minute symbol begins to flash Press CH or ...

Page 17: ...ll restart next day 1 When the alarm is ringing press the button to enter snooze mode the alarm will ring again in 5 minutes snooze interval And the symbol will be flashing on screen to indicate the snooze mode Press any other button except top button to exit the snooze mode And the alarm will restart next day 2 When the alarm rings the ascending Bibi alarm sound will last for 2 minutes If no oper...

Page 18: ...wireless interference Way 1 1 Remove the batteries of sensor 2 Press and hold the CH button for 3 4s then reload the sensor battery Notes If the re connection succeeds but it breaks again after a period of time please place the outdoor sensor at new location no more than 330 feet 100 meters open air from the weather station Way 2 Factory Restart 1 Remove all the batteries of sensor and main unit 2...

Page 19: ...e of temperature humidity It is not current time Incorrect weekday display Insufficient transmission distance The default Year setting of main unit is 2020 Press and hold SET C F button for 3 4 seconds to enter the time setting Please SET C F button to skip step until Year setting Please set current year Main unit and sensor transmits range up to 328ft 100m without obstruction You are near the sen...

Reviews: