Summary of Contents for Premium Line

Page 1: ...m Line Dear User To have efficient use of our product which has been under quality control please read the whole user manual carefully before taking the unit into use Save and keep the manual until th...

Page 2: ...rved The information contained in this manual and the accompanying products are copyrighted and all rights reserved by B Science Global ApS B Science Global ApS reserves the right to make periodic des...

Page 3: ...Safety Precautions 8 Refrigerant 8 Field of application 8 1 HAZARDS IDENTIFICATION 8 2 FIRST AID MEASURES 8 3 ACCIDENTAL RELEASE MEASURES 9 4 DISPOSAL CONSIDERATIONS 9 Chapter 5 Using the BMF Freezer...

Page 4: ...er Menu 24 1 Test Mode in ON mode 26 3 Update software firmware and parameter 27 4 Change Pin USER MENU 31 5 Set Time Date 31 6 Set Temperature 32 4 Temp Unit 40 5 Display 41 Chapter 6 Maintaining the...

Page 5: ...ers features so that you can use it efficiently 1 1 Intended use Do not locate or store your Freezer outdoors This model was designed for indoor use only and violation of this will void the terms of y...

Page 6: ...be kept open for free circulation of air inside the cabinet to avoid corrosion of the inner liner Environmental protection and disposal The packaging is designed to protect the appliance and its comp...

Page 7: ...pen ames or other ignition sources inside the appliance Never touch the Freezers interior or products in the Freezer when the Freezer is operating Use gloves or alike to avoid injuries frostbite Keep...

Page 8: ...the Freezer The Freezer should not be placed where it might be splashed with water in extreme high humidity or in direct sunlight Any of these factors may lead to a reduction in performance and shorte...

Page 9: ...he following organs Nervous System Vapor may cause flash fire Keep away from heat sparks and flame Do not puncture or incinerate container Keep container closed Use only with adequate ventilation Cont...

Page 10: ...e frozen tissue and seek medical attention 3 ACCIDENTAL RELEASE MEASURES PERSONAL PRECAUTIONS Immediately contact emergency personnel Keep unnecessary personnel away Use suitable protective equipment...

Page 11: ...been opened there will be a vacuum created inside the Freezer due to the low temperatures Wait a few moments before trying to reopen the door otherwise the handle could be damaged Temperature control...

Page 12: ...1 Date 2 Time 3 Temperature inside the cabinet 4 Room Temperature 5 Shows if compressor is running 6 Defrosting cycle activated 7 USB stick is connected 8 Battery status DISPLAY GIVES ACCESS TO 9 Temp...

Page 13: ...BMF FREEZER USER MANUAL 12 Main Menu In the main menu you get access to 1 Temperature graph 2 Status 3 Download 4 Menu 5 ON OFF 1 Temp Temperature graph Temperature graph for 1 day...

Page 14: ...MANUAL 13 Temperature graph for 7 days You can select a Temperature Map for either 1 or 7 days 2 Status 1 It shows the working hours of the compressor and the fan 2 It shows the last alarms that have...

Page 15: ...s ok 1 Use arrow up or down to change the value 2 To save the changed data click on the OK button Then return to download menu and push the Download button No 1 Every time you download data you will r...

Page 16: ...R MANUAL 15 4 Menu From menu you can gain access to 1 Admin menu Only access to authorized personal approved by B Science 2 Service menu 3 User menu 4 Temp unit 5 Display 6 Language this option is und...

Page 17: ...ervice Menu For access to service menu enter pin code 1 Put in Pin code and click on the OK button 2 Service Menu Service menu gives access to 1 Test Mode 2 Hysteresis 3 Manual defrosting 4 Change pin...

Page 18: ...e When the unit is Switched ON and running you can see Which relays are ON or OFF the temperature of each sensor and position of Door contact In this example The Compressor 1 and Fan 2 is running The...

Page 19: ...est Mode for troubleshooting in OFF mode When the unit is OFF you can simulate each relay by pushing the square field for testing each kind of device Compressor Light Fan motor etc Very good feature f...

Page 20: ...you can check all relays and door contacts and check the temperature sensors Switch OFF the unit by the display ON OFF button Type in the pin code for one of the pin codes levels and push the OK butt...

Page 21: ...ic component will be activated In this example the relay for Compressor 1 Defrost relay 1 Fan 1 Frame heater 1 and Light 1 are ON Alarm output has change from NC to NO or opposite The door no 1 is ope...

Page 22: ...REEZER USER MANUAL 21 2 Hysteresis Hysteresis settings The temperature between start and stop of the Compressor 1 Use arrow up or down to change the value 2 To save the changed data click on the OK bu...

Page 23: ...rt the defrost cycles in this menu manually by clicking on the YES button Now the defrost cycles will run automatically If you want to cancel the defrost cycle you must switch the unit OFF and switch...

Page 24: ...FREEZER USER MANUAL 23 4 Change Pin for SERVICE MENU If needed the service pin code can be changes under Change Pin 1 Put in New 4 numbered code 2 Repeat new pin code 3 Click the OK button to save cha...

Page 25: ...BMF FREEZER USER MANUAL 24 3 User Menu Enter pin code to access User menu 1 Put in Pin code and click on the OK button...

Page 26: ...BMF FREEZER USER MANUAL 25 3 User Menu In user menu you can get access to 1 Test Mode 2 Device Info 3 Update Data 4 Change Pin 5 Set Time 6 Set Temperature 7 Alarms...

Page 27: ...REEZER USER MANUAL 26 1 Test Mode in ON mode Test mode when the unit is switched ON 1 Test Mode Test Mode for when the unit is switched ON You can see which relay are ON or OFF and the sensors tempera...

Page 28: ...Here you should be able to see if there is a USB stick connected If the USB stick are not detected try to remove main power plug wait 10 seconds and connect main power plug again If there is still no...

Page 29: ...rotected you can use the same code as for USER SERVICE or ADMIN Press 4 numbers in and press OK Step 3 Press the MENU button to enter the next menu Step 4 Press the USER button to enter the next code...

Page 30: ...mware the controller will perform a rebooting Step 8 For uploading new parameter file you need to go from Step 3 to step 6 again In this UPDATE MENU you can see new detected parameters which are in gr...

Page 31: ...ler will perform a rebooting Important When you have updated all firmware and parameter remove the USB stick and switch ON the unit and always check the main parameters such as the Set point and Alarm...

Page 32: ...enu s pin code can be changed under Change Pin 1 Put in New 4 numbered code 2 Repeat new pin code 3 Click the OK button to save change 5 Set Time Date Setting the Date and Time 1 Use arrow up or down...

Page 33: ...ature in the cabinet 1 Use arrow up or down to change the value 2 To save the changed data click on the OK button In this example the setpoint are 20 0 C and the Hysteresis are 1 0 C That means the co...

Page 34: ...BMF FREEZER USER MANUAL 33 7 Alarms Under Alarms get access to 1 Alarm List 2 Temp Alarm 3 Alarm Delay 4 Door Alarm 5 Power Alarm...

Page 35: ...ng The Button will be red when the failure is activated and the remote alarm relay will be active until you click on the red button to deactivate the alarm Under the Sensor menu Sensor Menu When a Sen...

Page 36: ...BMF FREEZER USER MANUAL 35 2 Temperature Alarm To set up the High and Low temperature alarm 1 Use arrow up or down to change the value 2 To save the changed data click on the OK button...

Page 37: ...button 3 When the high or low temperature level are reached this alarm delay timer will start counting In this example where the high temperature alarm level is reached and the temperature inside the...

Page 38: ...4 Door Alarm To set alarm for Door alarm delay 1 Use arrow up or down to change the value 2 To save the changed data click on the OK button If the Door are left open for more than 3 minutes the Door o...

Page 39: ...he Power failure alarm will be activated Main Menu Alarm Screen When an alarm occurs you can choose to IGNORE or ACCEPT the alarm When you accept the alarm you are automatically taken to the Alarm Lis...

Page 40: ...Alarm Screen If you choose to IGNORE the alarm you are temporally ignoring the alarm and a red triangle will be visual on the main menu The Red triangle Alarm indicator will not disappear until it has...

Page 41: ...NUAL 40 4 Temp Unit Under Temp Unit you can select if you want the temperature range to be in Fahrenheit or in Celsius degrees 1 Push F or C the selected will turn green 2 To save the changed data cli...

Page 42: ...rrow up or down to change the value 2 To save the changed data click on the OK button The squares to the left 1 Help button future option 2 Screen number used for screen identification 3 Auto return A...

Page 43: ...here is a risk that the performance of the Freezer will be affected and even damage to the compressor could occur due to overheating Automatic Defrosting This BMF Freezer has Automatic Defrosting cycl...

Page 44: ...BMF FREEZER USER MANUAL 43 Time between each automatic defrost cycles Starting the manual defrost cycles...

Page 45: ...BMF FREEZER USER MANUAL 44 Wire diagram...