background image

 

 

 

Camano 

Wood Stove 

Owner's Manual 

 

Freestanding Stove 

 

Mobile-Home Approved  

 

Alcove Approved 

 

Hearth-Stove Approved 

Save these instructions  

for future reference 

 

 

SAFETY NOTICE:  

If this appliance is not properly installed, a house fire may 
result. For your safety, follow the installation directions. 
Contact local building or fire officials about restrictions and 
installation inspection requirements in your area. 

 

 

©

 Copyright 2010, 

Travis Industries, Inc. 

$10.00 

100-01252_000 

4101004 

 

 

Listed

 

Tested to: U.L. 1482, ULC S627, & ULC S628 

Summary of Contents for Camano

Page 1: ...e SAFETY NOTICE If this appliance is not properly installed a house fire may result For your safety follow the installation directions Contact local building or fire officials about restrictions and installation inspection requirements in your area Copyright 2010 Travis Industries Inc 10 00 100 01252_000 4101004 Listed Tested to U L 1482 ULC S627 ULC S628 ...

Page 2: ...n and operation of your new appliance an easier and more enjoyable experience We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your appliance Important Information No other Avalon Camano appliance has the same serial number as yours The serial number is stamped onto the label on the back of the appliance This serial number will be needed in cas...

Page 3: ...onry Chimney 17 Operating Your Appliance Safety Notice 18 Before Your First Fire 18 Opening the Door 18 Starting a Fire 19 Adjusting the Burn Rate 20 Ash Removal 20 Optional Blower Operation 21 Re Loading the Stove 21 Overnight Burn 21 Normal Operating Sounds 21 Hints for Burning 22 Selecting Wood 22 Troubleshooting 23 Maintaining Your Appliance Daily Maintenance 24 Remove Ash 24 Clean The Glass 2...

Page 4: ...ll children of the danger of a high temperature appliance Young children should be supervised when they are in the same room as the appliance 36 Keep furniture drapes curtains wood paper and other combustibles a minimum of 36 away from the front of the appliance This appliance must be properly installed to prevent the possibility of a house fire The instructions must be strictly adhered to Do not ...

Page 5: ...Allow the appliance to cool before carrying out any maintenance or cleaning Overfiring the appliance may cause a house fire If a unit or chimney connector glows you are overfiring Maintain the door and glass seal and keep them in good condition Do not operate this heater with broken or missing glass Avoid placing wood against the glass when loading Do not slam the door or strike the glass Do not u...

Page 6: ...ns Approximate Maximum Heating Capacity in square feet 750 to 1 400 Maximum BTU s per Hour Cord Wood Calculation 66 800 Maximum Burn Time Up to 8 Hours Heating capacity will vary depending on the home s floor plan degree of insulation and the outside temperature It is also affected by the quality and moisture level of the fuel Dimensions a 29 1 2 749mm 17 3 8 441mm 5 8 16mm 24 1 2 622mm 5 3 4 146m...

Page 7: ...pes of installations and the considerations for each type Alternative methods of installation are available if they comply with local building codes Installation Type Considerations Standard Ceiling with a Factory Built Chimney Page 15 Requires ceiling and roof penetration Provides best draft Cathedral Ceiling with a Factory Built Chimney Page 15 Cathedral style chimney support required Provides b...

Page 8: ...ll to stove 10 7 1 2 D Connector to sidewall 27 21 1 2 E Connector to backwall 19 1 2 11 1 2 F Connector to cornerwall 19 1 2 16 1 2 G Floor protection side and back 6 US 8 Canada 6 US 8 Canada H Floor protection front 16 US 18 Canada 16 US 18 Canada Reduced clearance installations require one of the chimneys and connectors listed below AMERI TEC model DCC with model HS chimney DURAVENT model DVL ...

Page 9: ...lation i Measure rear and side clearances from the stove top j Vent diameter varies depending on brand and model k Measure front clearances from the stove top 24 1 2 622mm 17 3 8 441mm 5 3 4 146mm i j k g g h a b d e Figure 2 Top View Corner Installation 24 1 2 622mm 17 3 8 441mm 5 3 4 146mm c f i j k g g h Figure 3 ...

Page 10: ...ired the installation shall conform to CAN CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment The chimney connector should be as short and direct as possible No more than 180o of elbows two 90o elbows or two 45o one 90o elbow etc may be used for the entire system connector and chimney Horizontal runs should slope upwards 1 4 per foot and be a maximum 36 long The chimney con...

Page 11: ...ings when passing through a ceiling see b below No more than 180o of elbows two 90o elbows or two 45o one 90o elbow etc may be used for the entire system connector and chimney NOTE Additional elbows may be allowed if draft is sufficient Whenever elbows are used the draft is adversely affected Additional chimney height may be required to boost draft a Min System Height 15 Max System Height 33 b Roo...

Page 12: ...ny portion of the roof within 10 of the chimney Chimney must extend 3 above the roof Chimney must extend 2 above any portion of the roof within 10 of the chimney Figure 5 Outside Air Requirements Required for mobile homes in certain localities check with local building official Must not be drawn from an enclosed space garage unventilated crawl space Requires the outside air kit sku 99200139 see a ...

Page 13: ... one of the above listed connectors NOTE Reduced clearance connectors may not connect to the flue collar an appliance adapter may be required Alcoves are classified as combustible or non combustible Non combustible alcoves must have walls and a ceiling that are 3 1 2 thick of a non combustible material brick stone or concrete see Figure 7 This non combustible material must be spaced and ventilated...

Page 14: ... collar an appliance adapter may be required Stove placement must maintain the following clearances to combustibles drywall furniture etc a b d e c f Figure 8 Minimum Clearance See the illustration above Reduced Clearance Connector A Sidewall to stove 13 B Backwall to stove 9 C Cornerwall to stove 7 1 2 D Connector to sidewall 21 1 2 E Connector to backwall 11 1 2 F Connector to cornerwall 16 1 2 ...

Page 15: ...chimney manufacturer s instructions and clearances for floor penetrations A ceiling support is required an attic insulation shield is required where insulation is present Insulation Minimum 15 4 57M Maximum 33 10 05M Figure 10 Cathedral Ceiling with a Factory Built Chimney Chimney Cap See the section Chimney Termination Requirements for more details Chimney Sections Minimum Air Space to Combustibl...

Page 16: ...ptional insulated chase Wall Bands and Supports Insulated Tee with cleanout Min 18 457mm clearance to ceiling Floor Protection See Floor Protection Requirements for details Minimum 15 4 57M Maximum 33 10 05M Figure 12 Hearth Stove Positive Connection Remove damper or wire it open Airtight Insulated Clean Out Min 18 457mm Combustible Mantle NOTE The entire fireplace and chimney must be clean undama...

Page 17: ...etails Combustible Mantle Min 18 457mm See the section Stove Placement Requirements for minimum clearances required Figure 14 Interior or Exterior Masonry Chimney NOTE This type on installation is not allowed in Canada NOTE This type of installation requires a UBC approved masonry connector or other method approved by the NFPA 211 standard See Chimney Connector Requirements on page 10 for further ...

Page 18: ... agent will soon dissipate Door Gasket The door gasket might adhere to the paint on the front of the heater Leave the door slightly ajar for the first fire and be careful when opening the door after the first fire 2 to 4 hours Over Firing the Stove This stove was designed to operate at a high temperature But due to differences in vent configuration fuel and draft this appliance can be operated at ...

Page 19: ...use DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPHTHA OR ENGINE OIL Do not place such fuel within space heater installation clearances or within the space required for charging and ash removal If using a firestarter use only products specifically designed for stoves follow the manufacturer s instructions carefully HOT WHILE IN OPERATI...

Page 20: ... use gloves or a tool to prevent burns The air control may take several minutes to influence the burn rate When making adjustments you may wish to let the stove burn for 10 minutes to gauge performance Ash Removal ASHES Ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a noncombustible floor or on the ground away from all combust...

Page 21: ...n 2 Open the door slightly Let the airflow inside the firebox to stabilize before opening the doors fully 3 Load wood onto the fire Overnight Burn This stove is large enough to accommodate burn times up to eight hours Follow the steps below to achieve an overnight burn 1 Move the air control to high burn and let the stove become hot burn for approximately 15 minutes 2 Load as much wood as possible...

Page 22: ...es less creosote Testing Wood Moisture Split wood stored in a dry area will be fully dry within a year This insures dry wood If purchasing wood for immediate use test the wood with a moisture meter Some experienced wood burners can measure wood moisture by knocking pieces together and listening for a clear knock and not a thud Wet Wood Leads To Leads To Dry Wood Leads To Leads To Less Heat More He...

Page 23: ...e cases a small amount of smoke may enter the home Adding more pipe or a draft inducing cap may help Stove Does Not Burn Hot Enough Wood is Wet see the section Selecting Wood on page 22 for details on wood Make sure the air control is all the way open Slide the control back and forth to insure the control is not stuck Insufficient Draft Chimney height and outside conditions can negatively affect d...

Page 24: ...e hearth to catch ash and protect against scratching 3 Open the door and scoop the ash into a metal container with a tight fitting lid The closed container of ashes should be placed on a noncombustible floor or on the ground away from all combustible materials pending final disposal ASHES Improperly disposed ashes lead to fires Hot ashes placed in cardboard boxes dumped in back yards or stored in ...

Page 25: ...etwen the door frame and cam To loosen the door cam add a washer between the door frame and cam Door Frame with gasket Washers Nut Door Handle 9 16 Wrench Cam Creosote Formation and Need for Removal When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condense in the relatively cool chimney flue of a slow burn...

Page 26: ...rom burning and creating odors The optional blower should be vacuumed every year to remove any buildup of dust lint etc Use a vacuum cleaner to remove any buildup on the screens of the blower BOTTOM OF STOVE Firebrick and Baffle Inspection Use the illustration on page 28 as a reference for checking the following items Make sure the appliance is cool before proceeding Baffle Firebricks check the br...

Page 27: ...ver tighten the glass clips Replacing the Door Gasket The door gasket inserts into the outer groove of the door RTV High temp silicone holds it in place Before installing remove any residual cement Lay the gasket in place start at the lower right corner and cut off any excess gasket do not stretch the gasket You may need to open and close the door repeatedly to get the gasket to seat fully Replaci...

Page 28: ...r Tube Roll Pins 6 98900357 4 Air Tube Retainer Sleeve 3 250 00042 5 Brick 9 x 4 5 un cut 16 251 00000 6 Brick Cut 9 x 2 25 3 251 00001 7 Brick Cut 9 x 1 375 2 251 00018 Floor and Side Firebrick Removal Replacement Do not pry firebrick they chip and crack easily Remove the floor firebricks first The side firebrick are removed later because they are pinned in place by the floor firebrick Clean the ...

Page 29: ...lt them downwards to remove Air Tube Removal Replacement All three air tubes are identical a b Remove the left pin on the air tube collar Air Tube Collar Air Tube Slide the air tube to the left swing it down and remove from the firebox Roll Pin Baffle Removal Replacement The baffle is held up by the front air tube Make sure to support the baffle after removing the air tubes Lift the four baffle fi...

Page 30: ...irebrick Breakage from thermal shock Accessories Legs Pedestal Blower Re Installation Allowance In cases where heater must be removed from home for repairs a partial cost of re installation is covered pre authorization required One Way Freight Allowance One way freight allowance on pre authorized repair done at factory is covered Exclusions Paint Gasketing Years 3 THROUGH 5 COVERAGE PARTS LABOR Fi...

Page 31: ...ers is not covered in this warranty Damage to the surfaces from over firing operation where the steel may glow red is not covered in this warranty 14 TRAVIS INDUSTRIES INC is free of liability for any damages caused by the appliance as well as inconvenience expenses and materials Incidental or consequential damages are not covered by this warranty In some states the exclusion of incidental or cons...

Page 32: ... CLEARANCE INSTALLATIONS REQUIRE One of the Listed doublewall connectors listed below In addition manufactured home installations require outside air use the optional pedestal or outside air boot AMERI TEC model DCC connector with model HS chimney DURA VENT model DVL connector with DURA PLUS chimney GSW JAKES EVANS SUPERPIPE 2100 I C C EXCEL 103 HT chimney with HP connector METALFAB model DW conne...

Page 33: ...lide the wire clip over the edge of the strip of metal between the two knock outs Feed the two snap disk wires into the eye of the wire clip Remove all slack from the wire making sure not to dislodge the snap disk Pinch the eye of the wire clip to secure the wires Wire Clip Snap Disk Wires WARNING To prevent electrical shock the wires must be secured so they do not contact the firebox above the co...

Page 34: ...oval 6 Exterior Chimney 12 Features 6 Fire Starting 19 Firebox Assembly 28 Firebox Parts 28 Firebrick and Baffle Inspection 26 Firebrick Removal Replacement 28 Floor Protection Requirements stove 8 Glass Cleaning 24 Glass Replacement 27 Hearth Floor Protection Stove 8 Hearth Stove 17 Heating Specifications 6 Hints for Burns 22 Installation Options 6 Installation stove 7 Listing Label 32 Maintenanc...

Reviews: