background image

  AUBER INSTRUMENTS

    

 

 

     

 

 

 

             

WWW.AUBERINS.COM  

 

2021.03                                                                                                                                                                                                          P1/5

 

 

JSL-64A 1/32 DIN General Purpose Timer 

Version 1.2 (March 2021) 

 

1. 

Overview

 

This JSL-64 timer can count from 0.01 second to 9999 minutes. Operating 
function modes include single delay, double delay, and cycle delay.  It can 
count-down or count-up. The timer can be activated automatically when 
powering up, by front key pad, or via remote switch. 

 

2. Specification 

Timer range: 0.01 second to 9999 minutes. 
Timer mode: single delay, double delay, cycle delay, count-up timer. 
Timer trigger: power on, front key pad, or remote switch. 
Timer error: < 1 s/day. 
Power supply: 85 - 260 V AC or DC. 
Power consumption: < 2 W. 
Relay output: 10A at 240 VAC / 30 VDC (resistive load) 
Average relay life: 100,000 times at rated current. 
Operating temperature: 0 - 60° C. 
Humidity: 0 - 95% RH. 
Panel cutout: 22 x 45 mm. 
Outer dimension: 24 x 48 x 75 mm (1" x 2" x 3"). 

 

3.

 

Front

 

Panel

 

 
 
 
 
 
 
 
 
 
 
 
 

Figure1. Front panel. 

 

1. Time unit indicator (colon sign): Turns on when time format is MM:SS 
(Minutes: Seconds) or HH:MM (Hours: Minutes) and flashes when the timer is 
running; turns off when time unit is M (Minutes) or S (Seconds). 
2. LED digital display: During normal operation as a timer, it displays the actual 
time. When timer is stopped, it displays the preset value. During controller 
setup, it displays parameter value. 
3. 

OUT

 indicator: Turns on when relay is on; turns off when relay is off. 

4. 

RUN

 indicator: Turns on when timer is running; blinking/flashing when timer 

is paused; turns off when timer is stopped. 
5. 

SET

 key: press it once to set timer and relay delay timer T1/T2 (if applicable. 

T1 timer shows as t-1, T2 timer shows as t-2); press and hold it for 3 second 
will enter the programming mode. This key is disabled when timer is running. 
 

6. 

DOWN

 key / STP key: Reduces the value in the programming mode; when 

the timer is running, press it to stop the timer. (For special stop function in 
single delayed on mode, please see note 6 on page 3 for details). 
7. 

UP

 key / PAU key: Increases the value in the programming mode; when 

timer is running, press and hold it will pause the timer; the timer will continue 
running after this key is released.  
8. 

RST

 key: Reset key. When the timer is running, press it will restart the timer. 

If "RUN" parameter is set to RST, press it will start the timer after powered up.  
 

4. Terminal Assignment 

6

7

8

9

10

1

2

3

4

5

OUT

ST

STP

PAU

RST

COM

AC

85~260V

 

Figure 2. Terminal assignment. 

 
 

Pin # 

Function 

Description 

Note 

Note: pin 1 to pin 5 are high voltage pins. 

AC power input 

85V ~ 260V AC power input. 

 

AC power input 

 

N.C. 

Not connected. 

 

Relay Output 

Normally open (NO) relay. The relay 
action is in synchronize with the OUT 
indicator. 

Relay Output 

Note: pin 6 to pin 10 are low voltage pins. 

Reset 

When connected with COM pin, 
works as the RST key to reset the 
timer. 

Pause 

When connected with COM pin, 
works as the PAU key to pause the 
timer. 

Stop 

When connected with COM pin, 
works as the STP key to stop the 
timer. 

Special 
Terminal 

Special terminal reserved for 
Espresso Shot Timer (EST) function. 

10 

Common 

Common pin. 

 

Note A

. Terminal 4 and 5 are for normally-open (NO) relay output. When this 

relay is energized (or when the OUT LED is on), pin 4 is connected to pin 5 
internally; When the relay is NOT energized (or when the OUT LED is off), pin 
4 is disconnected from pin 5

. The relay is a “dry switch” that does not provide 

power by itself. Please see the wiring examples in Section 7. 

Instruction Manual

 

 

1

4

5

6

7

8

2
3

Summary of Contents for JSL-64A

Page 1: ...d hold it for 3 second will enter the programming mode This key is disabled when timer is running 6 DOWN key STP key Reduces the value in the programming mode when the timer is running press it to stop the timer For special stop function in single delayed on mode please see note 6 on page 3 for details 7 UP key PAU key Increases the value in the programming mode when timer is running press and hol...

Page 2: ...f the keys on the timer are described below Please also refer to Section 6 for details of parameter RUN STOP and PAUS The settings of these parameters can affect the actual functions of STP PAU and RST key Key Action SET Shot press bring up the set value select parameter save value Long press bring up the parameter menu No action while timer is running STP Stops the timer from counting time May st...

Page 3: ... a special parameter STOP will appear in the parameter menu For details please refer to the Note 8 below DINT Delayed Interval The timer will count time for two periods of time T1 and T2 and then stops Relay action depends on the OUT setting When OUT OFDL the relay turns on at the end of T1 stays on during T2 time and then turns off at the end of T2 time When OUT ONDL the relay turns on at the beg...

Page 4: ...U key is pressed When PAUS 0 pressing the PAU key will only pause the timer and it will NOT affect the relay output status When PAUS 1 pressing the PAU key will not only pause the timer but also change a relay output status from ON to OFF However it will not affect relay status if the relay is OFF 7 Wiring Examples 1 Signal controlled by switches Power 120 or 240V AC is sent to pin 1 and 2 The ext...

Page 5: ...be triggered when stop key switch is released voltage from low to high Power Relay output Reset Pause Stop T1 Ta Tb Ta Tb T1 Figure 10 a Single delay and off delay FUNC SDL OUT OFDL Power Relay output Reset Pause Stop 0 T1 Ta Tb Ta Tb T1 Stop 1 Figure 10 b Single delay and on delay FUNC SDL OUT ONDL for the STOP parameter please see Note 8 on page 2 for details Power Relay output Reset Pause Stop ...

Reviews: