Solid-state Twin Timer

H3DE-F

Operates in flicker-OFF or flicker-ON start mode
with one Unit.

Independent ON- and OFF-time settings. 
Combinations of long ON- or OFF-time and short
OFF- or ON-time setting are possible.

Long time range from 0.1 s to 12 h for both ON and
OFF time settings.

Ordering Information

Operating mode

Supply voltage

Model

Flicker-OFF/Flicker-ON start

24 to 230 VAC/VDC

H3DE-F

 Model Number Legend

H3DE -

1

1.

F: Twin timers

 Accessories (Order Separately)

Mounting Track

50 cm (l) x 7.3 mm (t)

PFP-50N

1 m (l) x 7.3 mm (t)

PFP-100N

1 m (l) x 16 mm (t)

PFP-100N2

End Plate

PFP-M

Spacer

PFP-S

Summary of Contents for H3DE-F

Page 1: ...setting are possible Long time range from 0 1 s to 12 h for both ON and OFF time settings Ordering Information Operating mode Supply voltage Model Flicker OFF Flicker ON start 24 to 230 VAC VDC H3DE F Model Number Legend H3DE 1 1 F Twin timers Accessories Order Separately Mounting Track 50 cm l x 7 3 mm t PFP 50N 1 m l x 7 3 mm t PFP 100N 1 m l x 16 mm t PFP 100N2 End Plate PFP M Spacer PFP S ...

Page 2: ...unit display e sca e d sp ay see note 1 sec 10 s min hrs x 0 1 0 1 to 1 2 s 1 to 12 s 0 1 to 1 2 min 0 1 to 1 2 h x 1 1 to 12 s 10 to 120 s 1 to 12 min 1 to 12 h Note 1 Time scale display is applied commonly for ON and OFF time 2 When the main dial is set to 0 for all settings the output will operate instantaneously Ratings Rated supply voltage see note 24 to 230 VAC VDC 50 60 Hz Operating voltage...

Page 3: ...litude at 10 to 55 Hz Shock resistance Malfunction 100 m s2 approximately 10G Destruction 1 000 m s2 approximately 100G Life expectancy Mechanical 10 million operations min under no load at 1 800 operations h Electrical 100 000 operations min 5 A at 250 VAC resistive load at 360 operations h EMC EMI EN50081 1 Emission Enclosure EN55022 class B Emission AC Mains EN55022 class B Harmonic Current EN6...

Page 4: ...time setting dial OFF time setting dial OFF time unit display window ON OFF start selector default is flicker OFF start OFF time unit selector select one from s 10s min or h Front View Bottom View ON OFF Start Selector Switch Settings Setting Operating mode Flicker ON start Flicker OFF start Operation Block Diagram AC DC input Power supply circuit ON indicator OFF indicator Indicator circuit ROM R...

Page 5: ...nit selector select one from s 10s min or h OFF time unit selector select one from s 10s min or h OFF time unit display window Time Scale Selection The time scale selector on the upper left side of the front panel can be set to 0 1 or 1 as a magnification coefficient Time scale display window Time scale selector ON time setting dial OFF time setting dial Time Setting Use the ON OFF time setting di...

Page 6: ...H3DE F 19 Dimensions H3DE F Terminal block black Surface color Light gray 5Y7 1 OMRON Terminal block black Installation Terminal Arrangement Note DC supply voltage does not require the designation of polarity ...

Page 7: ...se indicated Dimensions Mounting Track PFP 100N PFP 50N PFP 100N2 L Length 1 m PFP 100N 50 cm PFP 50N 1 m PFP 100N2 End Plate PFP M Spacer PFP S 4 5 15 25 25 25 25 10 10 L 7 3 0 15 35 0 3 27 0 15 1 4 5 15 25 25 25 25 15 10 10 L 35 0 3 27 24 16 29 2 1 1 5 50 11 5 M4 x 8 pan head screw 10 6 2 1 8 1 35 5 35 3 1 8 1 3 4 8 5 16 12 44 3 16 5 10 34 8 ...

Page 8: ... supplies can be connected to the power in put terminals without regarding polarity With the H3DE only a DC power supply must be connected to the power input terminals as designated according to the polarity of the terminals A DC power supply can be connected if its ripple factor is 20 or less and the mean voltage is within the rated operating voltage range of the Timer Connect the power supply vo...

Page 9: ...ct Contact or transistor for external input signal Correct H3DE Power supply B1 A1 A2 H3DE B1 A1 A2 Short circuit current Contact or transistor for external input signal H3DE Power supply B1 A1 A2 H3DE B1 A1 A2 Short circuit current The H3DE Series is provided with a transformerless power supply system Wiring H3DE H The H3DE has a high impedance circuit Therefore the H3DE may not be reset if the H...

Page 10: ...ll as very acidic or basic solutions can damage the outer casing of the Timer Do not use the Timer in places where it is exposed to dust corrosive gas or direct sunlight When storing the Timer make sure that the ambient temperature and humidity are within the rated values Leave the Timer at room temperature for at least three hours before using the Timer if it has been stored at an ambient tempera...

Page 11: ...6028 Japan Phone 81 6 6949 6035 Fax 81 6 6949 6069 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No L092 E1 3C In the interest of product improvement specifications are subject to change without notice Printed in Japan 0299 2M a ...

Reviews: