NOTICE: 

This equipment has been tested and it complies with 

the limits for a Class a digital device, pursuant to Part 

15 of the FCC Rules. These limits are designed to 

provide a reasonable protection against harmful 

interference when the equipment is operated under a 

commercial environment. This equipment generates, 

uses, and can radiate radio frequency energy and, if 

not installed and used in accordance with the 

instruction manual, may cause harmful interference to 

radio communications. Operation of this equipment in 

a residential area is likely to cause harmful 

interference in which case the user will be required to 

correct the interference at his own expenses. 

Note

: All brands and trademarks shall belong to their 

respective owner. 

Note

: Specification is subject to changes without 

notice. 

This  device complies  with  Part  15  of  the  FCC  Rules. 

Operation  shall  be  subject  to  the  following  two 

conditions: 

(1) This device may not cause harmful interface, and 

(2) This  device  must  accept  any  interface  received, 

including  interface  that  may  cause  undesirable 

operation. 

Summary of Contents for AS-8150

Page 1: ...ual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expenses Note All brands and trademarks shall belong to their respective owner Note Specification is subject to changes without notice This device complies with Part 15 of ...

Page 2: ...lt shown as bold label 2 Set interface to optimize protocol of the scanner with your host in interface section 3 Set system control of the scanner such as specific adjustments double confirm indicator and scanning mode which you prefer using in the system control section 4 Set code options of the scanner for your usage in the code option section You must make sure to enable the symbology first the...

Page 3: ...2 ...

Page 4: ... 9 Chapter 2 Parameter Setting Interface Interface Selection 11 USB HID Keyboard 12 RS 232 15 Pin Assignments 18 System Control Scan mode 19 Indication 25 Code Option UPCA 27 UPCE 32 EAN 13 36 EAN 8 40 Code 39 44 Interleaved 2 of 5 49 Industrial 2 of 5 50 Matrix 2 of 5 Eur 52 Codabar 54 Code 128 57 Code 93 61 Code 11 64 MSI Plessey 66 ...

Page 5: ...RSS Limited 81 GS1 Databar Expanded RSS Expanded 83 String Format String Setting Transmission Prefix Suffix 85 String Setting Transmission Preamble Postamble 87 String Setting Transmission Insert Group Characters 89 String Setting Transmission Others 93 Datamagic 95 Appendix Test Chart 101 ASCII Code Table 104 Parameter setting List 105 ...

Page 6: ...rt 4 Plug the power pack into a power source 5 Once the scanner has been fully connected turn the terminal computer power back on USB HID Simulate with keyboard wedge 1 Connect the USB cable between scanner and PC 2 Windows will automatically detect the USB device USB Com 1 Connect the USB cable between scanner and PC 2 Windows will automatically detect the USB device Note If any of the above oper...

Page 7: ... V V V A UPC E V V V E EAN 13 V V V F EAN 8 V V V FF Code 39 V Interleaved 2 of 5 V i Industrial 2 of 5 i Matrix 2 of 5 B Codabar Code 128 V V Code 93 V two digits Code 11 V One digit O MSI Plessey V UK Plessey V Telepen S Standard 2 of 5 i GS1databar Omnidirectiona V R4 GS1databar Limited V RL GS1databar Expanded V RX China Post t Italian Pharmacode p ...

Page 8: ... Width 120 mm Scan Speed 200 scans sec Resolution 0 1mm 4mils Code39 PCS 90 Print Contrast 30 or more Scanning Angle Front 60 Rear 60 Yaw 75 Decode Capability Auto discriminates all standard barcodes Other symbologies can be ordered optionally 2D symbologies for 8250 and 8312 only Beeper Operation 7 tones or no beep Indicator Green led Mechanical Length 182 mm Width handle 26 mm Width head 74 mm D...

Page 9: ...Voltage 5 VDC 0 25V Power Operating 1275 mW Power Standby 600 mW Current Operating 255 mA 5 VDC Current Standby 120 mA 5 VDC DC Transformers Class 2 5VDC 450 mA Agency listing UL FCC Class A CE Environmental Operating Temperature 0 to 45 32 to 113 Storage 40 to 60 40 to 140 Humidity 5 to 90 relative humidity non condensing Light Level Up to 60000 Lux Shock 1 5m drop onto concrete Contaminants Seal...

Page 10: ...ogrammable characteristics Code type selection check digit selection Decoding option Decoding option Transmitted character delay Header selection trailer selection message suffix good read beep tone and volume scanner trigger selection Keyboard emulation type intermessage delay keyboard type and keyboard language Serial interface type ACK NAK Xon Xoff RTS CTS good read LED control start stop bits ...

Page 11: ... must 1 Scan the Program barcode on the parameter setting part 2 Enter the option mode by scanning the Option Bar Code also on the Parameter setting part 3 To the right of the option barcode the necessary alphanumeric inputs are listed Scan these alphanumeric entries from the last page To confirm above steps you must scan the Finish barcode on the last page 4 Once you have finished programming Sca...

Page 12: ...tion Alphanumeric Entry Interface selection Keyboard Wedge RS 232 Wand emulation USB RS 232 Auto detection Reserved 00 01 02 03 04 05 Program Exit Program Barcode Option Barcode Exit Barcode On the last page Finish barcode ...

Page 13: ...ction You can change factory interface default for another type interface By plugging different cables setting right interface the scanner will change to another interface However you must make sure which cable you need RS232 USB HID Auto detection By setting this function it will automatically select the RS 232 or USB HID interface for the user Option Bar Code Option Alphanumeric Entry Interface ...

Page 14: ...pplication program while the barcode datas contain ASCIIvalues between 0116 to 1F16 Refer to ASCII table Numeric Key The Keypad has to be selected if your application program is only keypad numeric code acceptable The scanner will output code as you press the numeric keypad when it reads a numeric digit The keypad is on the right side of keyboard and Num Lock control key is also on If Alt Keypad i...

Page 15: ...ayout USA Belgium Danish France Germany Italian Portuguese Spanish Swedish Switzerland UK Latin American Japanese 00 01 02 03 04 05 06 07 08 09 10 11 12 Function key Disable Enable 00 01 Numeric key Alphabetic key Numeric keypad Num lock state 00 01 Program ...

Page 16: ...15 Exit only Alt Keypad 02 Caps lock Caps lock ON Caps lock OFF 00 01 ...

Page 17: ...ter the timeout Response Delay duration the scanner will issue a 5 warning beeps Xon Xoff When the host computer is unable to accept data it sends a Xoff code to inform the scanner to suspend data transmission and Xon to continue ACK NAK When the ACK NAK protocol is used the scanner waits for an ACK acknowledge or not acknowledge from the host computer after data transmission and will resend in re...

Page 18: ...owledgment from the host computer Option Bar Code Option Alphanumeric Entry Flow control None RTS CTS Xon Xoff ACK NAK 00 01 02 03 Inter character delay 00 99 msec 00 99 00 Block transmission delay 00 99 10 msec 00 99 00 Response delay 00 99 100 msec 00 99 20 Program ...

Page 19: ...phanumeric Entry Baud rate 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS 38400 BPS 57600BPS 115200BPS 01 02 03 04 05 06 07 08 09 Parity None Odd Even 00 01 02 Data bit 8 bits 7 bits 00 01 Stop bit One bit Two bits 00 01 Program ...

Page 20: ...19 Pin Assignments RS 232 DB 9F Connector To Host Side Pin Definition 1 NC 2 TXD 3 RXD 4 NC 5 GND 6 NC 7 CTS 8 RTS 9 VCC 5V 4 2 3 1 8 6 9 7 5 ...

Page 21: ...d Continue Scanner always keeps reading and it does not matter when the trigger button is pressed or duration has elapsed Test only For test of scan performance only This should not be used to be utilized to check the accuracy of transmitted data Double read timeout The scanner will require several successful decodings to confirm the data when enabled The more confirm times required the more inhib...

Page 22: ...tary Alternate Timeout off Continue led on Test only Continue led off 00 01 02 03 04 05 06 Stand by duration 01 99 second 00 99 06 Double read timeout 01 99 10 msec 01 99 50 Double confirm 00 99 00 no double confirm 00 09 00 Supplement Check Counter 00 99 verifications 00 99 5 Program ...

Page 23: ...he settings for individual barcode by the min max code length setting of each barcode Notes 1 Please set the min max length if you have special demand for individual barcode 2 Include the Check sum digits if you want to set Global min max code length Inverted image scan Set Enabled the scanner will scan both black white barcode with white black background CTS trigger This operation enables an exte...

Page 24: ... Exit Option Bar Code Option Alphanumeric Entry Global min code length 00 99 00 99 4 Global max code length 00 99 04 99 99 Inverted image scan Disable Enable 00 01 CTS trigger Disable Enable 00 01 Program ...

Page 25: ...u aim at the bar code prior to scanning The code will not be scanned until you press the trigger Stand mode selection Normally activated with continuous mode If it is set as LED off the scanner red beam will turn off automatically if not used but will turn on again immediately when scanning bar codes ...

Page 26: ...25 Exit Option Bar Code Option Alphanumeric Entry Position indication Disable 30 second 60 second 90 second 120 second 150 second 180 second Continue 00 01 02 03 04 05 06 07 Program ...

Page 27: ...nner will light up to indicate a good barcode reading Beeper indication After each successful reading the scanner will beep to indicate a good barcode reading and its Beep loudness Beep tone freq and Beep tone duration are adjustable Beep loudness Beep tone freq Beep tone duration You can adjust Beep Loudness Beep tone and Beep duration for a good reading to your preferred setting Exit ...

Page 28: ...umeric Entry Power on alert Disable Enable 00 01 LED indication Disable Enable 00 01 Beeper indication Disable Enable 00 01 Beep loudness 00 07 00 07 07 Beep tone freq 00 99 100Hz 00 99 40 Beep tone duration 00 99 10 msec 00 99 10 Program ...

Page 29: ...instead of reading anything when the truncate value is more than the barcode data digits or the value of Truncate Leading is overlapped with that of the Ending The maximum value of truncate digits is 15 Code ID setting Code ID setting is a character used to represent the symbol upon a successful reading A Code ID setting is prefixed to the data begin or end transmitted if the feature is selected I...

Page 30: ... Alphanumeric Entry Read Disable Enable 00 01 Check sum transmission Disable Enable 00 01 Datamagic Disable Enable 00 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH A Program ...

Page 31: ...ata of selected symbologies Enable the group insertion by selecting the group number Example Group 2 set 02 or 20 Group 1 and 4 set 14 or 41 Notes 1 Group number set to 0 means that no group insertion required 2 Details about the Insert Group settings please refer to page 98 101 and page 107 ASCII code table Supplement digits The Supplement digits barcode is the supplemental 2 or 5 characters for ...

Page 32: ...tion Bar Code Option Alphanumeric Entry Insert group number selection 00 44 00 44 00 Supplement digits None 2 digits 5 digits 2 5 digits UCC EAN 128 2 UCC EAN 128 5 UCC EAN 128 All 00 01 02 03 04 05 06 07 Program ...

Page 33: ...its of UPCA data characters can be truncated when the function is enabled Option Bar Code Option Alphanumeric Entry Truncation Expansion None Truncate leading zero Expand to EAN13 00 01 02 Supplement Check Counter 00 99 verifications 00 99 5 The Program ...

Page 34: ...Enable checks sum will be transmitted Truncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Check sum transmission Disable Enable 00 01 Datamagic Disable Enable 00 01 Program ...

Page 35: ...34 Exit Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH E ...

Page 36: ...n The expansion function is used only for UPCE and EAN 8 code reading It extends to 13 digits with 0 digits when the feature is enabled Example Barcode 0123654 Output 0012360000057 UPCE 1 Enable scanner to read UPCE with leading digit 1 Option Bar Code Option Alphanumeri c Entry Insert group number selection 00 44 00 44 00 Supplement digits None 2 digits 5 digits 2 5 digits UCC EAN 128 00 01 02 03...

Page 37: ...CC EAN 128 All 05 06 07 Truncation Expansion None Truncate leading zero Expand to EAN13 Expand to UPCA 00 01 02 03 Expansion Disable Enable 00 01 UPCE 1 Disable Enable 00 01 Supplement Check Counter 00 99 verifications 00 99 05 ...

Page 38: ...s sum will be transmitted Truncate leading ending Refer to Truncate leading ending of UPCA Truncate leading zero Refer to Truncation Expansion of UPCA The Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Check sum transmission Disable Enable 00 01 Datamagic Disable Enable 00 01 Program ...

Page 39: ...38 Exit Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 ...

Page 40: ...e ISBN International Standard Book Number and ISSN International Standard Serial Number are two kinds of barcode for books and magazines The ISBN is 10 digits with leading 978 and the ISSN is 8 digits with leading 977 of the EAN 13 symbology Example Barcode 9789572222720 Output 9572222724 Example Barcode 9771019248004 Output 10192484 Option Bar Code Option Alphanumeric Entry Code ID setting 00 ffH...

Page 41: ...plement digits None 2 digits 5 digits 2 5 digits UCC EAN 128 2 UCC EAN 128 5 UCC EAN 128 All 00 01 02 03 04 05 06 07 ISBN ISSN conversion Disable Enable 00 01 Supplement Check Counter 00 99 verifications 00 99 05 ...

Page 42: ...ing ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 30 Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Check sum transmission Disable Enable 00 01 Datamagic Disable Enable 00 01 Program ...

Page 43: ...42 Exit Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting Two characters 00 ffH ASCII code 00 ffH 00 ffH FF Insert group number selection 00 44 00 44 00 ...

Page 44: ...nsion Refer to Truncate Leading zero of UPCE Expansion Refer to Expansion of UPCE Option Bar Code Option Alphanumeric Entry Supplement digits None 2 digits 5 digits 2 5 digits UCC EAN 128 2 UCC EAN 128 5 UCC EAN 128 All 00 01 02 03 04 05 06 07 Truncation Expansion None Truncate leading zero Expand to EAN13 00 01 02 Program ...

Page 45: ...44 Exit Expansion Disable Enable 00 01 Supplement Check Counter 00 99 verifications 00 99 05 ...

Page 46: ...Max Code Length is in effect The length is defined as to the actual barcode data length to be sent Labels with lengths that exceed these limits will be rejected Make sure that the Minimum length setting is no greater than the Maximum length setting or otherwise all the labels of the symbology will not be readable In particular you can see the same value for both Minimum and Maximum reading length ...

Page 47: ...e Disable Disable Enable Enable Enable 00 01 02 Datamagic Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 01 Truncate leading 0 20 00 20 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH ...

Page 48: ...ot transmit the embedded appending code space for Code 39 If Enable and other symbols were read again with the appended code then codes will be transmitted without Code ID Preamble and Prefix When a symbol is decoded without the appended code the data will be transmitted without Code ID and Prefix but the Postamble Suffix codes are appended This function is used when the first number of code 39 is...

Page 49: ...48 Exit Format Standard Full ASCII 00 01 Append Disable Enable 00 01 Start end transmission Disable Enable 00 01 ...

Page 50: ... be transmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 30 Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Check sum transmit verify Disable Disable Disable E...

Page 51: ... Enable 00 01 Max code leading 00 64 00 64 00 Min code leading 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH i Insert group number selection 00 44 00 44 00 ...

Page 52: ...cate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 30 Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Datamagic Disable Enable 00 01 Max code length 00 64 00 64 00 Program ...

Page 53: ...52 Exit Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH i Insert group number selection 00 44 00 44 00 ...

Page 54: ...be transmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 30 Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Transmit Verify Disable Disable Disable Ena...

Page 55: ...e Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH B Insert group number selection 00 44 00 44 00 ...

Page 56: ...ransmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Transmit Verifiy Disable Disable Disable Enable Enable Enable 00 01 02 Start Data Digits Variable Checksum Optional End Program ...

Page 57: ...56 Exit Datamagic Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH ...

Page 58: ...of Start End patterns you may select one pair to match your application Start End Transmission Refer to Start End Transmission of Code 39 Option Bar Code Option Alphanumeric Entry Insert group number selection 00 44 00 44 00 Start End type ABCD ABCD abcd abcd ABCD TN E abcd tn e 00 01 02 03 Start End transmission Disable Enable 00 01 Program ...

Page 59: ... is made as the sum module 103 of all data digits Checksum Transmission By setting Enable checksum will be transmitted Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Transmit Verify Disable Disable Disable Enable Enable Enable 00 01 02 Datamagic Disable Enable 00 01 Program ...

Page 60: ...n group number selection Refer to Insertion group number selection of UPCA Format The Code 128 can be translated to UCC EAN 128 format if it starts with a FNC1 character The first FNC1 will be translated to C1 and next to be a field separator code as GS 1D16 C1 Data GS Data Checksum Option Bar Code Option Alphanumeric Entry Max code length 00 64 00 64 00 Min code length 00 64 00 64 01 Program ...

Page 61: ...60 Exit Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Insert group number selection 00 44 00 44 00 Format Standard UCC EAN 128 00 01 ...

Page 62: ... ID setting To set the code ID for UCC EAN 128 output format Field separator code This feature is only used for UCC EAN 128 format This Field separator code means you can reassign second or after a FNC1 for your usage The default of ASCII code is GS 1D16 Option Bar Code Option Alphanumeric Entry Append Disable Enable 00 01 UCC EAN 128 ID setting 00 ffH ASCII code 00 ffH Field separator code 00 ffH...

Page 63: ...s made as the sum module 47 of the numerical values of all data digits Checksum Transmission By setting Enable checksum will be transmitted Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Transmit Verify Disable Disable Disable Enable Enable Enable 00 01 02 Datamagic Disable Enable 00 01 Program ...

Page 64: ...g ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Program ...

Page 65: ...64 Exit Code ID setting 00 ffH ASCII code 00 ffH Insert group number selection 00 44 00 44 00 ...

Page 66: ...m verification method Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Transmit Verify Disable Disable Disable One ...

Page 67: ...e Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH O Insert group number selection 00 44 00 44 00 ...

Page 68: ...m module 10 or 11 of the data digits Checksum Transmission By setting Enable checksum1 and checksum2 will be transmitted upon your selected checksum verification method Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to Insertion group...

Page 69: ...od 10 10 N mod 11 10 Y Mod10 Y Mod 10 10 Y Mod 11 10 00 01 02 03 04 05 06 Datamagic Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 00 ffH ASCII code 00 ffH ...

Page 70: ...69 Exit Code ID setting Insert group number selection 00 44 00 44 00 ...

Page 71: ...n By setting Enable checksum will be transmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Transmit Verify D...

Page 72: ...le Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Insert group number selection 00 44 00 44 00 ...

Page 73: ...code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Transmit Verify Disable Disable Disable Enable Enable Enable 00 01 02 Data...

Page 74: ... 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH S Insert group number selection 00 44 00 44 00 Format Numeric only Full ASCII only 00 01 ...

Page 75: ...ill be transmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Check sum Transmit Verifyn Disable Disable Disable Enabl...

Page 76: ...ble Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH i Insert group number selection 00 44 00 44 00 ...

Page 77: ...ncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Datamagic Disable Enable 00 01 Max code length 00 64 00 64 11 Program ...

Page 78: ...77 Exit Min code length 00 64 00 64 11 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH t Insert group number selection 00 44 00 44 00 ...

Page 79: ...ng ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to Insertion group number selection of UPCA Leading A If this function is enabled each prefix of data shall be A Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Datamagic Disable Enable 00 01 Program ...

Page 80: ...00 64 00 64 12 Min code length 00 64 00 64 09 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 01 ffH p Insert group number selection 00 44 00 44 00 Leading A Disable Enable 00 01 ...

Page 81: ...ting Refer to Code ID setting of UPCA Insertion group number selection Refer to Insertion group number selection of UPCA UCC EAN 128 emulation Refer to Transmission Code ID transmission must be set as AIM ID enable Then C1 will be identified as the prefix of barcode data transmission Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Program ...

Page 82: ...gic Disable Enable 00 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH R4 Insert group number selection 00 44 00 44 00 UCC EAN128 emulation Disable Enable 00 01 ...

Page 83: ...UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to Insertion group number selection of UPCA UCC EAN 128 emulation Refer to UCC EAN 128 emulation of RSS 14 Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Datamagic Disable Enable 00 01 Truncate leading 0 15 00 15 00 Program ...

Page 84: ...83 Exit Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH RL Insert group number selection 00 44 00 44 00 UCC EAN128 emulation Disable Enable 00 01 ...

Page 85: ...efer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to Insertion group number selection of UPCA UCC EAN 128 emulation Refer to UCC EAN 128 emulation of GS1 Databar Omnidirectional Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Max code length 00 99 00 99 99 Program ...

Page 86: ...de length 00 99 00 99 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH RX Insert group number selection 00 44 00 44 00 UCC EAN128 emulation Disable Enable 00 01 ...

Page 87: ...efined as prefix or suffix characters will be transmitted immediately with the scanned data for all symbologies Up to 22 ASCII characters can be defined as Prefix or Suffix Format of barcode data transmission Prefix Name Preamble ID Code Length Barcode Data ID Postamble Suffix Insert groups ...

Page 88: ...87 Exit Option Bar Code Option Alphanumeric Entry Prefix characters setting None 1 22 characters 00 00 ffH ASCII code Suffix characters setting None 1 22 characters 0D 00 ffH ASCII code Program ...

Page 89: ...be appended before the data transmitted Postamble transmission By setting Enable Postamble will be appended after the data is transmitted Example Add a prefix suffix or preamble postamble for all symbologies In this example you are sending a symbol as a prefix for all symbologies Steps 1 Scan Programming and Prefix characters setting barcode 2 Use the ASCII code table to find the value of 24 3 Sca...

Page 90: ...ric Entry Preamble characters setting None 1 12characters 00 00 ffH ASCII code Postamble characters setting None 1 12haracters 00 00 ffH ASCII code Preamble transmission Disable Enable 00 01 Postamble transmission Disable Enable 00 01 Program ...

Page 91: ...insertion will be positioned at the ending of data Notice Default value 00 indicates the group to be positioned at the leading of data 64 represents for positioning the group at the ending of data Insert data group setting procedure i Define the characters of groups for insertion ii Setup the inserting position of each group in scanned data iii Select one or two groups to insert into specific bar ...

Page 92: ...ition The scanner offers 4 positions to insert among the symbols The position default value is 00 to indicate no character insertion In addition make sure insertion positions are not greater than the symbols otherwise the insertion data is not effective Option Bar Code Option Alphanumeric Entry Insert G1 characters setting None 1 12haracters 00 00 ffH ASCII code Insert G2 characters setting None 1...

Page 93: ...ing None 1 12 characters 00 00 ffH ASCII code 8AI Insert G5 characters setting None 1 12 characters 00 00 ffH ASCII code 8AJ Insert G6 characters setting None 1 12 characters 00 00 ffH ASCII code 8AK Insert G7 characters setting None 1 12 characters 00 00 ffH ASCII code 8AL Insert G8 characters setting None 1 12 characters 00 00 ffH ASCII code Program ...

Page 94: ...characters setting None 1 12 characters 00 00 ffH ASCII code Insert data group 1 position 00 63 00 no insertion 00 63 00 Insert data group 2 position 00 63 00 no insertion 00 63 00 Insert data group 3 position 00 63 00 no insertion 00 63 00 Insert data group 4 position 00 63 00 no insertion 00 63 00 ...

Page 95: ...th of the barcode is the number of barcode data except Truncate Leading Ending Digits And the length is a number with two digits Code name transmission This function is to show unknown barcode symbologies that include all readable symbologies of the scanner When Enable is selected Code Name will be transmitted before code data to let you know what kind of barcode symbology it is Case conversion Se...

Page 96: ...ter code data 00 01 Code ID transmission Disable Proprietary ID AIM ID 00 01 02 Code length transmission Disable Enable 00 01 Code name transmission Disable Enable 00 01 Case conversion Disable Upper case Lower case For barcode data only 00 01 02 ...

Page 97: ... allows a maximum of 10 Rules Functions are described below Each Rule has the following structure Leading RuleNo Action Parameter1 Parameter2 Leading 9 indicates DataMagic RuleNo 0 9 indicates Rule No 0 No 9 RULE1 RULE2 RULE3 RULE4 RULE5 RULE6 RULE7 RULE8 ...

Page 98: ...97 RULE9 RULE10 Action 0 9 0 Insert Front 1 Cut Front 2 Cut Back 3 Replace 4 Keep Front 5 Keep Back ...

Page 99: ...Front 7 Find Cut Back 8 Insert Back 9 Erase Parameter1 Each function is indicated differently Parameter2 Each function is indicated differently To erase all of the DataMagic setting values just scan the barcode below ...

Page 100: ...99 To display all of the current related setting results scan Program OR DataMagic settings Inserted Group settings ...

Page 101: ...a insert a group at a specified position from the front Para1 specifies the insert position starting from position 0 Para2 specifies the group to insert Example Program RuleNo Action Para1 Para2 Exit RULE1 Insert Front 0 5 0 4 RULE1 Rule No Insert Front Action at the 5th position from the front Para1 insert Group 4 Para2 Data ARGOX89121121 Result ARGOXTel 89121121 ...

Page 102: ...101 Programming for the example above Program RULE1 Insert Front Para1 Two digits Para2 Two digits Finish Exit ...

Page 103: ...102 Test Chart Bar code samples marked with symbol are enabled initially CODABAR CODE 11 CODE 128 CODE 39 CODE 93 EAN 13 ...

Page 104: ...103 STANDRAD 25 EAN 8 INDUSTRIAL 25 UPCE INTERLEAVED 25 ...

Page 105: ...104 MATRIX 25 MSI PLESSEY UPCA UK PLESSEY GS1 dat bar ...

Page 106: ...F5 ENQ NAK 6 PgDn F6 ACK SYN 7 F7 BEL ETB 8 Bs F8 BS CAN 9 Tab F9 HT EM A F10 LF SUB B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl SO RS F Delete Alt SI US L H 2 3 4 5 6 7 0 SP 0 P p 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O _ o DEL ...

Page 107: ...ique parameter list If you wish to display the unique parameter setting list scan the unique parameter list bar code System parameter setting list If you wish to display the product information and revision number for your AS 8110 8120 8150 8250 8310 8312 scanner over the host terminal computer scan the System parameter setting list bar code String setting list If you wish to display the string fo...

Page 108: ...re version list If you wish to display the Datamagic setting scan the Query Datamagic Setting barcode Query present scanner firmware version Program Firmware version list If you wish to display the firmware version scan the Firmware version list barcode ...

Page 109: ...t scanner to factory default settings Program WARNING Default value initialization If you wish to return the AS 8150 8250 REV B to all the factory default settings scan the Default value initialization bar code ...

Page 110: ...109 0 1 2 3 4 5 6 7 8 9 A B C Finish F E D ...