background image

SYNERGII SHOWER PANEL  

RIGHT HAND OPERATION 

SY02910 | SY02910B

INSTALLATION AND CARE INSTRUCTIONS

Important Information

• Hot and cold water inlet pressures should be equal.
•  Operating static pressure is 300—500kpa. If pressure exceeds this, then an 

approved pressure limiting valve must be fitted.

•  Pipework must be flushed out prior to installation of the shower panel. Damage 

caused to the shower panel by debris coming through the pipework is not 
covered under warranty.

•  Installation should comply to AS/NZS3500.1 2003 or the relevant local 

requirements.

• Maximum hot water temperature is 75°C. 
• Not suitable for gravity feed applications.

 

 

Maintenance and care

•  Using a soft cloth with a mild detergent or soap is all that is required to clean 

surfaces.

•  Do not use abrasive cream cleaners or citrus based cleaning products. These will 

damage the surface.

•  The spray channel of overhead shower is protected by a self-cleaning system. If 

scale deposits are noticed in the spray channel, turn water on lightly and rub the 
spray channels with a finger or sponge. 

WARRANTY

Guarantee

 

Arcisan shower panels are covered by a 7 year conditional residential warranty subject to 
the terms below.
>  7 year product or parts warranty against manufacturing defects. (Hoses and hand sprays 

on kitchen mixers are 2 years).

> 1 year replacement product or parts and labour warranty.
Streamline reserves the right to assess, fix, replace or service warranty claims as they see fit. 
The warranty period applies from date of purchase or date of handover for new buildings. If 
this is not available, the manufacturing date stamp on the product will be used.
Warranty claims should first be directed through the point of purchase. It is mandatory that 
the purchaser provide proof of purchase and the warranty is valid for the original purchaser 
only and is not transferable.

Exclusions

 

The warranty does not apply to the following cases:
•  Blocked or damaged aerators are not covered under the warranty. Other damage caused 

by not flushing the system before connection or use.

•  Damage caused by improper installation, abuse, accident and misuse. Also previous repair 

or alteration without the company’s or agent’s permission.

•  Warranty only applies to items purchased through an authorised re-seller within Australia.
•  Tapware used in a commercial setting. This is subject to a 1 year parts and labour warranty.
•  General wear and tear from normal use of the product, including scratching from cleaning.
•  Water temperature or pressure exceeds the stated maximums. The maximum water 

pressure is 500kpa and maximum temperature is 75 degrees Celsius.

Consequential Damages

 

Streamline Products will not liable for damage to other items (floor coverings, walls, lights 
and other fittings) or any other type of consequential losses caused by a defect in the 
product, except when the failure amounts to a major failure under your statutory rights.

Statutory Rights

 

Our goods come with guarantees that cannot be excluded in the Australian Consumer Law. 
You are entitled to a replacement or refund for a major failure and for compensation for 
any other reasonably foreseeable loss or damage. You are also entitled to have the goods 
repaired or replaced if the goods fail to be of acceptable quality and the failure does not 
amount to a major failure.

Contact

 

This warranty is provided by Streamline Products P/L 
Phone: 1300 735 352  
Email: [email protected]

Summary of Contents for SYNERGII SY02910

Page 1: ...ll be used Warranty claims should first be directed through the point of purchase It is mandatory that the purchaser provide proof of purchase and the warranty is valid for the original purchaser only and is not transferable Exclusions The warranty does not apply to the following cases Blocked or damaged aerators are not covered under the warranty Other damage caused by not flushing the system bef...

Page 2: ...ket to wall For mounting position refer to Recommended Installation Height page Step 3 Screw flexible hoses onto wall connections making sure the correct hoses are connected to the correct outlets Do not over tighten the nuts Once the connections are made turn on mains water to check for leaks Step 4 Carefully hang the shower panel onto the mounting brackets ensuring that both top and bottom brack...

Page 3: ...rovided within this specification sheet is correct at the date of printing Please confirm all particulars with your sales consultant prior to purchase Version 1 0 March 2017 www streamlineproducts com au Ph 1300 735 352 Recommended height set up for Synergii Shower Panel Right Hand Operation SY02910 SY02910B 2200 1090 1290 1490 1790 2110 All heights to finished floor ...

Page 4: ...ct at the date of printing Please confirm all particulars with your sales consultant prior to purchase Version 1 0 March 2017 www streamlineproducts com au Ph 1300 735 352 Set out for recommended height of Synergii Shower Panel Right Hand Operation SY02910 SY02910B 1680 20 Centre line of shower panel 20 565 100 1360 40 1460 1115 Mounting bracket Mounting bracket Cold inlet 1 2 BSP Hot inlet 1 2 BS...

Reviews: