background image

     
                 Instruction Sheet for Aqua-Flash  

   

 

  Effective 6/30/17                    

           Instant Hot Water Recirculation System 

        

 

  IS-AM09-597 

           Kit No. AMH1K-3UV & RS100 & RS101 

 

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

 

 

Page 1 of 2 

 

Installation and Operating Instructions 

NSF 372 Certified   

Thank you for choosing the Aqua-Flash Instant Hot Water Recirculation System by AquaMotion, Inc. 
Please read and follow these step by step instructions to ensure that the system operates properly and reliably. Since the cold water supply line will be 
used to return the cooling hot water to the hot water heater you will experience some warm water from the cold water line. Opening the cold water faucet 
fully will flush the warm water from the cold line in a short period of time. After the Flash valve has been installed, system will need to cycle through from 
hot to cool several times or overnight before normal operation is established. 

Warning: This is not an anti-scald valve.  

Inspection 

Inspect the system components to ensure no damage has occurred to them during shipping. Avoid dropping the circulator which may get damaged if 
dropped.  

The Aqua-Flash includes: 
AM3 AquaMotion Circulator with a built-in timer and a 10 Ft line cord. 
AquaMotion Flash By-Pass Valve 
3/8” x ½” x 3/8” Compression Tee 

 

 

 

 

 

 

¾” NPT Female Tail Piece with 1 ½” Union Nut and Gasket 
12” Long ½” x ½” Flex Hose 
Installation and Operating Instructions 
 

Tools Needed: 

5/8” open end wrench 
15/16” open end wrench or an adjustable crescent wrench that opens to 1” 
Pipe wrench that opens to 2” 
 

Limits 

Maximum water temperature 110

C/230

Maximum Pressure Rating 125 psi 
 

Pump Installation 

Warning: For Indoor Use Only 
Warning: Do not plug the pump in until the pump installed is complete. 

1) 

Shut off the cold water supply to the water heater. This may be on the cold supply line above the tank or located where the water line enters 
the residence. 

2) 

Open a hot water faucet in the residence and allow the water to run until it stops. Leave the faucet open until the installation has been 
completed. 

3) 

Remove the hot water line from the hot water heater at the threaded outlet pipe at the top of the tank. 

4) 

Place the large union nut over 

the threaded outlet pipe before threading the ¾” NPT Tail Piece onto the threaded outlet pipe. 

Fig. 1.

 

 
 
 

Fig. 1. 

Fig. 2.

 

 

 

 

 

 

 
 
 
 
 

 
 

5) 

Place the union gasket on the tail piece and thread the large union nut onto the circulator. 

Fig. 2. 

 

 

6) 

Reconnect the hot water line that was removed in step 3 to the circulator. 

Fig. 3. 

Use pipe dope or Teflon Tape to seal the threads. If flex 

hoses are used at this connection, then no pipe dope of Teflon Tape are required. 

 

 
 
 

 
 
AquaMotion Inc

.   88 C Jefferson Blvd., Warwick, RI 02888   Tel:  401-785-3000  Fax:  401-785-3033 

                               Copyright 2017 

– AquaMotion Inc. 

                               Printed in USA 

 

Отзывы: