Visage

Digital

Exposed with adjustable height head

The Waste Electrical and Electronic Equipment
(Producer Responsibility) Regulation 2004

This product is outside the scope of the European Waste Electrical

and Electronic Equipment Directive as interpreted within the UK.

In the UK this product can therefore be disposed of through

commercial non-WEEE waste facilities.

The original manufacturer does not accept any liability under the

WEEE directive within the UK.

In other EU countries the WEEE directive may apply and, at end

of life, product must be disposed

of at a suitable WEEE recycling centre

Содержание Visage Digital Exposed

Страница 1: ...pe of the European Waste Electrical and Electronic Equipment Directive as interpreted within the UK In the UK this product can therefore be disposed of through commercial non WEEE waste facilities The original manufacturer does not accept any liability under the WEEE directive within the UK In other EU countries the WEEE directive may apply and at end of life product must be disposed of at a suita...

Страница 2: ...Visage Digital exposed installation instuctions page 2 Shower systems Visage Digital exposed standard with adjustable height head ...

Страница 3: ...Visage Digital exposed installation instuctions page 3 Components Standard Pumped ...

Страница 4: ...initial supervision or instruction concerning the use of the product by a person responsible for their safety Children should be supervised to ensure they do not play with the product Installation of Digital pumped processor for gravity stored systems The Visage Digital pumped shower system is designed to operate up to maximum static pressure of 100kPa 1 bar 10 metres head 14 5psi Under no circums...

Страница 5: ...ularly on the outlet will reduce the flow rate at the shower head If long pipe runs are unavoidable use copper pipe rather than plastic If plastic pipe is used minimise the number of elbows as the pipe inserts are very restrictive Consideration should be given to using 22mm plastic or copper pipe on the outlet especially if a diverter is installed Flushing Some modern fluxes can be extremely corro...

Страница 6: ...tly and safely Visage Digital is supplied with universal fittings 90mm 445mm 270mm 350mm 265mm 70mm To ensure safe operation and installation of this product the processor MUST be installed in one of the orientations shown 1 Isolation valves are supplied with the Digital processor and must be fitted on both inlets and the blended water outlet All pipe work should be run in 15mm pipe All pipe work ...

Страница 7: ...f 3 THE PROCESSOR MUST BE SITED IN A POSITION THAT IS SAFELY ACCESSIBLE FOR SERVICING AND COMMISSIONING PURPOSES WHEN FITTED IN THE LOFT SPACE THE ROUTE TO AND THE AREA AROUND THE PROCESSOR MUST BE BOARDED TO ENSURE A SAFE WORKING ENVIRONMENT The optimum position for the Digital processor is in the roof space above the shower site to take full advantage of the ease and speed of installation please...

Страница 8: ... screws provided 11 The ceiling plate cannot be sited against an uneven surface If there is coving or an alternative obstruction please ensure the entry hole is neat and unobtrusive otherwise the copper tube could be visible within the showering area Place the rail bracket support pillar into the desired location ensuring that both the hose restraint and handset holder are below the rail wall brac...

Страница 9: ...AMOUNT OF ELBOWS TO MAXIMISE FLOW RATES WE RECOMMEND USING COPPER PIPE WITH THE MINIMUM AMOUNT OF ELBOWS Before any electrical adjustment is attempted the electricity supply must be turned off at the mains switch ELECTRICAL INSTALLATION MAY ONLY BE CARRIED OUT BY A QUALIFIED PERSON Offer the data cable into the rear of the controller in the correct orientation Push the data cable into position ens...

Страница 10: ...wer for 15 seconds without the handset attached to clear any internal debris which may be present Turn off the shower and pass the hose through the gel hook hose restraint if required 22 Connect the low voltage data cable into the socket adjacent to the temperature adjuster as indicated on the label Feed the cable out of the processor box ensuring it is correctly routed within the data cable chann...

Страница 11: ...plied factory set with the flow rate at either NORMAL HP or NORMAL GRAVITY mode depending on which shower system has been ordered STANDARD PROCESSORS ON BALANCED HP SYSTEMS Standard processors fitted to balanced high pressure systems may be set to NORMAL HP or for water economy ECO modes STANDARD PROCESSORS ON COMBINATION BOILER SYSTEMS For Standard Digital processors installed on combi boiler sys...

Страница 12: ...s fully to enable the slider to be moved up or down the rail 3 Angular adjustment is made by carefully but firmly pulling forwards or pushing back the shower head against the knuckle ratchet in the holder Cleaning Your Visage Digital shower system should be cleaned using only a soft cloth and washing up liquid DO NOT USE ABRASIVE CLEANERS To reduce the need for chemical descaling in hard water are...

Страница 13: ...of Ireland 01 844 3212 Brochure Hotline 0800 652 3669 Website www aqualisa co uk Email enquiries aqualisa co uk Please note that calls may be recorded for training and quality purposes The company reserves the right to alter change or modify the product specifications without prior warning Registered Trademark Aqualisa Products Limited Part No 468603 Issue 04 Feb 10 ...