background image

USERS’ MANUAL

MODEL SMTNR2-1

PANEL MOUNT TERMINAL

ANAHEIM AUTOMATION

910 E. Orangefair Lane

Anaheim, CA 92801

Phone: (714) 992-6990

Fax: (714) 992-0471

http://www.anaheimautomation.com

email: [email protected]

#L010100

August  20, 1998

Summary of Contents for SMTNR2-1

Page 1: ...DEL SMTNR2 1 PANEL MOUNT TERMINAL ANAHEIM AUTOMATION 910 E Orangefair Lane Anaheim CA 92801 Phone 714 992 6990 Fax 714 992 0471 http www anaheimautomation com email info anaheimautomation com L010100...

Page 2: ...ogrammable Function keys 1 2 3 F1 F2 4 5 6 F3 F4 7 8 9 YES NO 0 SPACE BKSP ENTER Default Keypad Outputs KEY DEC HEX ASCII 0 48 30H 0 1 49 31H 1 2 50 32H 2 3 51 33H 3 4 52 34H 4 5 53 35H 5 6 54 36H 6 7...

Page 3: ...oming data Additionally the PARITY option can be set to NONE DISPLAY PE When PARITY is set to EVEN ODD MARK or SPACE and DISPLAY PE is set to ENABLED any character received containing a parity error i...

Page 4: ...column numbers are absolute with row 1 column 1 Pr H20 Pc H20 representing the upper left corner of the display CURSOR HOME ECS H Note that this command is functiopnally equivalent to the Cursor Posit...

Page 5: ...ion ESC A CURSOR UP ESC B CURSOR DOWN ESC C CURSOR RIGHT ESC D CURSOR LEFT ESC E CLEAR DISPLAY AND GO HOME ESC F UNDERSCORE CURSOR ON ESC G UNDERSCORE CURSOR OFF ESC H CURSOR HOME ESC I CLEAR DISPLAY...

Page 6: ...TRL B 02H 34 22H 3 ETX CTRL C 03H 35 23H 4 EOT CTRL D 04H 36 24H 5 ENQ CTRL E 05H 37 25H 6 ACK CTRL F 06H 38 26H 7 BEL CTRL G 07H 39 27H 8 BS CTRL H 08H 40 28H 9 HT CTRL I 09H 41 29H 10 LF CTRL J 0AH...

Page 7: ...H 74 J J 4AH 106 j j 6AH 75 K K 4BH 107 k k 6BH 76 L L 4CH 108 l l 6CH 77 M M 4DH 109 m m 6DH 78 N N 4EH 110 n n 6EH 79 O O 4FH 111 o o 6FH 80 P P 50H 112 p p 70H 81 Q Q 51H 113 q q 71H 82 R R 52H 114...

Page 8: ...to transmit a character string to the handheld terminal which produces a character string on the termnal display Write Value This function allows the user to transmit a numerical values to the ternmi...

Page 9: ...te that there are 20 Characters per Row and 4 Rows to display your instruction Limit Your Instruction to 20 Characters per Line 1 Row Pressing the OK button will insert the command into the program Wh...

Page 10: ...es the X Axis Motor Position Value The SMTNR2 1 allow the user to verify the numerical value of any register that is being updated within a program Example s Batch Count Register Number of Cycles Regi...

Page 11: ...GO HOME ESC F UNDERSCORE CURSOR ON ESC G UNDERSCORE CURSOR OFF ESC H CURSOR HOME ESC I CLEAR DISPLAY ESC J ERASE CURSOR TO END OF DISPLAY ESC K ERASE CURSOR TO END OF LINE ESC L SOUND LONG BELL ESC M...

Page 12: ...in the RV Register Once the user enters a numerical value the SMC40 Program the numerical entry followed by a carriage return Pressing ENTER will be loaded into the RV RegisterValue with the Numerica...

Page 13: ...FLUSH MOUNT CLOSED BACK MOUNTING HARDWARE FLUSH MOUNT CLOSED BACK...

Page 14: ...FLUSH MOUNT OPEN BACK MOUNTING HARDWARE FLUSH MOUNT OPEN BACK...

Page 15: ...SMTNR2 1 DIMENSIONS...

Page 16: ......

Reviews: