background image

OPERATING GUIDE for your

 

GEM-DXK1 KEYPAD 

© NAPCO 2006 

OI325  11/06 

SYSTEM READY 
10/01/06   12:09 AM 

Summary of Contents for GEM-DXK1 KEYPAD

Page 1: ...1 OPERATING GUIDE for your GEM DXK1 KEYPAD NAPCO 2006 OI325 11 06 SYSTEM READY 10 01 06 12 09 AM ...

Page 2: ...of readiness by testing it at least once a week in both the ac battery and battery only modes ask your alarm professional how to make these tests INTRODUCTION IMPORTANT TEST YOUR SYSTEM WEEKLY Test your sounding device and backup battery These tests should only be performed on weekends or at a time designated by your alarm company 1 While disarmed press R 2 Answer NO press Q until ACTIVATE BELL TE...

Page 3: ...CELL PHONE STYLE 24 SETTING THE DATE AND TIME 26 KEYPAD MESSAGES 27 GLOSSARY 30 SYSTEM TROUBLE ERROR CODES 33 TROUBLESHOOTING 38 TO SILENCE AN ALARM ENTER YOUR CODE AND PRESS U FOR SERVICE CALL _____________________ CENTRAL STATION _____________________ EXIT DELAY ___________________________ ENTRY DELAY _________________________ FIRE ALARM SOUND _____________________________________ BURGLAR ALARM ...

Page 4: ...4 R 1 2 3 B 4 5 6 C 7 8 9 0 P Q G U SYSTEM ARMED 09 01 07 12 00 AM ARMED STATUS KEYPAD CONTROLS INDICATORS 1 2 3 4 5 6 7 8 9 10 11 12 ...

Page 5: ...ctors Numerical Keys 1 9 0 Used to enter codes zone numbers etc ENTER Button Entry key Causes the entered code or selected function to be executed STAY Button 1 Bypasses all Interior Zones simultaneously STAY Mode to allow free movement within the premises Hold down P when the system is armed in STAY Mode to cancel entry delay on Exit Entry Zones causing an instant alarm upon violation 2 Scrolls t...

Page 6: ...aining in 10 second steps Note If you enter a wrong code the keypad will display INVALID ENTRY TRY AGAIN 3 Leave the premises Leave through the exit door before exit time expires Priority Arming If you attempt to arm with a faulted Zone a 3 second tone will sound at the keypad CAN T ARM SYSTEM and ZONES FAULTED will display in the window indicating that the faulted zone s must be secured before th...

Page 7: ...o arm disarm a different area 1 Press the numerical key representing the other area number 2 Press Gfollowed by U The keypad will now provide status and control of that area 3 Enter your User Code followed by Q to arm or disarm the area 4 Press G followed by U to return to the home area Global Arming Optional Available only with the GEM P3200 9600 panels To arm all areas simultaneously press 9 G a...

Page 8: ... instant protection press and hold down P for 2 seconds at any time after the system is armed When armed with Instant Protection opening the entry door will cause an immediate alarm When arming with Instant Protection the exit delay will remain in effect allowing exit of the house just after arming While armed the window will display SYSTEM ARMED SYSTEM ARMED I will display with the GEM P9600 3200...

Page 9: ...the system awaking the family Press U to activate Easy Exit on your system GEM P3200 GEM P9600 V20 or greater GEM P816 P1632 V9A or greater Emergency Buttons Only available if programmed The Blue Emergency Buttons 7 8 9 if programmed are always active whether the system is armed or disarmed The emergency signal will only be transmitted when an Emergency Button and G are pressed at the same time Fi...

Page 10: ...is disarmed the window will continue to display ALARM followed by the zone s violated 2 To reset the display note the zones violated then press C Ambush Optional Your Ambush Code Type is TYPE 1 Prefix TYPE 2 Unique My Ambush Code is ___________________ If an intruder forces you to disarm your system enter your Ambush Code and press U There are two types of Ambush Codes 1 A 2 digit code prefix ente...

Page 11: ... a smoke detector tripped its red alarm indicator light will be on After the alarm condition is corrected thermostat cooled down smoke cleared from detector etc pressing C again will reset the keypad within about 10 seconds NOTE When the Fire Zone is reset the FIRE icon on the left side of the display will go out If the FIRE icon is still displayed the fire zone has not been properly reset If you ...

Page 12: ...ith all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals escape quickly Do not stop to pack 3 Test the door If it is hot use your alternate route through the window If the door is cool brace your shoulder against it and open it cautiously Be ready to slam the door if smoke or heat...

Page 13: ...13 FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan ...

Page 14: ...res because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors will not detect oxygen levels smoke toxic gases or flames Therefore they may only be used as part of a comprehensive fire detection system in conjunction with other devices Under no circumstances should thermostatic heat d...

Page 15: ...ed for longer than one minute Display Zone Faults Displays the zone number of zones that are not secured If needed press the NEXT and PRIOR Buttons as displayed on screen to scroll faulted zones required for GEM P3200 9600 panels GEM P816 1632 panels will auto scroll Display Zones Bypassed Displays bypassed zones If needed press NEXT P and PRIOR Q to scroll bypassed zones required for GEM P3200 96...

Page 16: ...ays trouble conditions that have been detected on the Fire Zone s Use NEXT P and PRIOR Q to scroll zones required for GEM P3200 9600 panels GEM P816 1632 panels will auto scroll Activate Chime The Chime Mode will sound a tone at the keypad when the programmed zone is faulted while disarmed To deactivate the Chime Mode re enter the Function Mode and when DEACTIVATE CHIME is displayed press YES P No...

Page 17: ...the Function Menu scroll to RESET SENSOR MSG and press U If you cannot correct the problem call for service Note This function available with GEM P9600 and GEM P3200 control panels only Start Exit Time Optional Start Exit Time programmed YES NO In Commercial Burglary systems exit delay may have been programmed to start after a central station ringback verification signal has been received If the r...

Page 18: ... 4 hours To Delay Arm the system With the function TO ARM IN 1 4 HRS displayed in the window enter the desired Delay Arming time in hours 1 2 3 or 4 followed by U At the end of this 1 4 hour Delay Arming period the siren will sound a 2 second warning and the keypad will begin a 15 minute arming countdown with the sounder pulsing The sounder may be silenced at this time by pressing C but it will tu...

Page 19: ...to the next group or PRIOR Q to scroll back to the previous group Press C when done Note This function available with GEM P9600 and GEM P3200 control panels only Relay Group 01 ____________________________________ Relay Group 02 ____________________________________ Relay Group 03 ____________________________________ Relay Group 04 ____________________________________ Relay Group 05 _______________...

Page 20: ...p to 45 sec onds at your option by consulting with your installer Regular Burglary Non 24 Hour Zone reports are aborted by disarming within the delay period 24 Hour Zones and zones programmed to report restores must be restored first then the panel armed and disarmed all within the delay period Opening and or Closing Reporting Your system can notify the central station every time it is disarmed or...

Page 21: ...ntral station acknowledges receipt ringback exit delay will start If ringback is not heard within about 30 seconds a communication problem may exist call for service Function 11 Start Exit Time may then be used to manually start the exit delay however reporting capability may be sacrificed If your system does not report or the ringback feature was not programmed exit delay will start as soon as yo...

Page 22: ...e when U is pressed Repeat Steps 1 through 3 for each User Code to be programmed Erasing a User Code 1 Enter the digits of the user number to be erased followed by RR 2 Press G0 to erase each digit of the User Code and then press U Example Erase User 3 s 4 digit User Code For the GEM X255 panel enter all three digits of the User Press 03RRG0G0G0G0 U User Program Mode Your Installer has programmed ...

Page 23: ... panel enter all three digits of the user number 4 Press U to save the code Note Duplicate Codes are not allowed therefore a duplicate Code entered in the LCD Window will erase when U is pressed Press C to exit the Program Mode Notes If the system contains more than one keypad only the keypad designated No 1 may be used for programming if in doubt which is No 1 ask your installer While in Program ...

Page 24: ...the next zone or to any other zone Move the cursor to the displayed zone number i e 01 using R and B Change the zone number using keys 0 through 9 Enter two digits for the zone number after entering the first digit the cursor will automatically advance to the second digit When the second zone number digit is entered the cursor will automatically advance to the right allowing the description locati...

Page 25: ...QUENCE 1 ABC1 1 abc1 2 DEF2 2 def2 3 GHI3 3 ghi3 4 JKL4 4 jkl4 5 MNO5 5 mno5 6 PQR6 6 pqr6 7 STU7 7 stu7 8 VWX8 8 vwx8 9 YZ90 9 yz90 0 SPACE 0 Reserved CELL PHONE STYLE ENTRY Use R and B buttons to move the cursor as needed Press U to save Hold G and press number to display lowercase letters in sequence R RIGHT B LEFT C U SPACE EXAMPLE Repeatedly press 3 to display G H I 3 in sequence SAVE ...

Page 26: ... enter 07 29 00 2 Press U to save the Date Programming the Time After entering in the Date press NEXT P for the Time Entry screen 1 At the Enter Time screen simply punch in the correct time using the numeric keypad buttons and if necessary press any numeric button to change the AM display to PM or vice versa For example for 6 30 PM enter 06 30 0if necessary 2 Press U to save the Time Programming t...

Page 27: ...ndicates Service Code active I indicates arming with Instant protection Entry delay in progress XXX shows entry time remaining in seconds System armed With the GEM P3200 9600 panels the I indicates arming with Instant protection Zones not secured doors or windows may be open Faulted zone s will scroll Arming attempted with faulted zone The display will scroll the zone faults Secure the zone s and ...

Page 28: ...ress C to silence sounder Evacuate premises or correct cause of alarm For partitioned systems only Code not valid for area Wrong code entered or Easy Bypass function not enabled In Manager s Mode Arming prevented due to unsecured zone represents number of area with unsecured zone Press area number then the G button then U to view zones in that area Correct problem then arm as normal For GEM P3200 ...

Page 29: ... receives an acknowledgment from the central station of the cancellation of the alarm signal Indicates problem s detected on system See examples below and SYSTEM TROUBLE ERROR CODES for a complete list of system troubles and corrective actions Check power transformer Check for blown fuse or circuit breaker general power outage Battery weak If not recharged within 24 hours replace battery Communica...

Page 30: ... by its own keypad or by a keypad of a different Area through Managers Mode Arming Disarming Turning the system on off by entering your code at the keypad then pressing U Battery Backup power source in the control panel enclosure to provide protection in the event of a power failure BYPASS Button Enables you to manually remove one or more protective zones from the system Central Station Monitors i...

Page 31: ...bort Delay see Abort Delay Report A transmission to a central station notifying of a change in the status of the system alarm trouble low battery etc RF Low Battery Wireless sys tems only Weak transmitter battery RF Check In Wireless systems only Periodic test report from transmitter if a report is not received on time a supervisory failure system trouble will result Ringback A beep after arming v...

Page 32: ...delay only occurs if re entry takes place through the normal exit entry door first Fire Zone Detects fire alarms or trouble conditions Interior Zones Circuits within the premises usually including space protection devices interior doors etc but not exterior doors or windows These can all be bypassed simultaneously using the P button Priority Zone A zone that prevents arming if in trouble Priority ...

Page 33: ...n System Trouble Condition Action E01 00 AC Power Failure This trouble will occur if AC power is not present Make sure system transformer is plugged into AC receptacle and check the circuit breaker otherwise call installing company for service E02 00 Low Battery If there has been a recent power failure the battery may be partially depleted and must be recharged by the control panel The control pan...

Page 34: ...required for the GEM PIR and GEM GB The replacement battery for the GEM SMK is the Duracell MN1604 9 Volt Alkaline 2 required The GEM DT Dual Technology Sensor requires 4 C cell alkaline batteries Warning Replace batteries only with the same type as specified above Use of another battery may present a risk of fire or explosion Do not recharge or disassemble battery or dispose of in fire E06 NN Rec...

Page 35: ...se Fail ure NN Relay Board Number Call installing company for service E15 NN RF Transmitter Tamper Wireless Transmitter Tamper Cover removed NN Transmitter Number Call installing company for service E16 NN Wireless Receiver Jam A problem has been detected with the wireless receiver Call installing company for service E17 NN Receiver Tamper Condition Call installing company for service E18 NN KeyFo...

Page 36: ... the sensor is able to detect activity in the area clear any obstacles which may be blocking the sensor from detecting activity Press C to clear the display and then use the Function Menu to Reset Sensor Watch Failure see page 17 If you cannot correct the problem yourself call installing company for service E23 00 Burglary Bus Failure Call installing company for service E24 00 Service Message The ...

Page 37: ...ire zone indicated Call installing company for service GEM P1632 and GEM P816 panels only E51 00 Bell Siren Trouble There is a problem with the Bell or Siren Call installing company for service E58 00 Telemetry Trouble Call installing company for service E59 00 Telemetry Failure Call installing company for service E66 00 Dirty Smoke Detector Clean Me indication Smoke Detector dirty Call installing...

Page 38: ... the scrolling error codes which represent the trouble Press C and you will now be able arm to the system but the trouble must be fixed as soon as possible See Page 7 33 The Fire Alarm is sounding and I don t know how to turn it off If a fire is in progress evacuate the premises immediately If necessary call the Fire Department from an outside phone If there is no evidence of a fire enter your cod...

Page 39: ...39 NOTES ...

Page 40: ...o any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system may not be compromised or circumvented or that the product or system will prevent any personal injury or property loss by burglary robbery fire or otherwise nor that the product or system will in all c...

Reviews: