background image

AMPERIS PRODUCTS

USER MANUAL

 

Gas Detection Thermal Imaging Camera  

AMPERIS TC706

Summary of Contents for TC706

Page 1: ...AMPERIS PRODUCTS USER MANUAL Gas Detection Thermal Imaging Camera AMPERIS TC706...

Page 2: ...GAS DETECTION THERMAL IMAGING CAMERA AMPERIS TC706...

Page 3: ...n graphic interface 18 Shortcut key interface 19 Measurement Object Adding 20 Recording 21 Photo 22 Settings 23 General setting 24 General setting Temperature measurement setting 29 General setting Ad...

Page 4: ...packing box when storing the equipment and place it in a cool dry close the lens cap It is recommended to backup In order to prevent the potential danger of data loss please copy backup the data to t...

Page 5: ...wave infrared quantum well focal plane array detector electronic processing systems and image processing software the infrared radiation measurement object is converted to visual thermal images to lo...

Page 6: ...RIES Standard TC 706 infrared gas leakage thermal imager Shoulder strap Safety box Lens cap Li on Battery 2pcs Charger Video output cable Power adapter SD Card SD Card reader User manual Network cable...

Page 7: ...er saving mode LCD brightness adjustment Video output NTSC or PAL Network settings Time date settings Factory reset SD card unloading formatting SD card capture video storage Capture voice or text ann...

Page 8: ...amera Note after shutting down turn on the boot again at least 20 seconds to ensure that the thermal imager is safe 2 Menu button 3 3 3 Cancel Auto 5 5 5 Long press for more than 3 seconds IR auto mod...

Page 9: ...www amperis com 9 support info amperis com t 34 982209920 FUNCTION KEYS AND INTERFACE Name Function 6 F1 custom 7 F2 shortcut 3 lights 8 F3 shortcut K 7O E 7 9 Microphone 8...

Page 10: ...www amperis com 10 support info amperis com t 34 982209920 FUNCTION KEYS AND INTERFACE Name Function 11 T interface 83D VKWX 12 Power interface OY9 13 9 14 3...

Page 11: ...e battery face down if the opposite direction can not be inserted do not force too much damage to the instrument or battery Note The instrument should use the standard battery otherwise the battery si...

Page 12: ...months 3 113 F 45 C to 149 F 60 C once every month Battery should have greater than 50 charge prior to recharge The ambient temperature for charging should be 32 F 0 C to 104 F 40 C If under 32 F 0 C...

Page 13: ...lling the battery press the thermal imager power switch more than 3 seconds until the boot screen appears After about 15 minutes the instrument is initialized and entered into the working state Open t...

Page 14: ...t object the Enter key the screen is displayed on the temperature object properties measurement temperature measurement area of the property dialog box tance and reference object left and right keys t...

Page 15: ...ties of the temperature measurement area can modify the ratio distance maximum temperature minimum temperature average temperature maximum temperature difference and reference temperature left and rig...

Page 16: ...fter you open the image you could use upper and lower sections of the playback control panel keys to playback the current store images Press Cancel key to exit and return to the current state 1 Press...

Page 17: ...the lower menu Cancel and return to the previous menu button Save and return to the previous menu button For touch screen www amperis com 17 support info amperis com t 34 982209920 OPERATION Quick Gu...

Page 18: ...temperature measurement white crosshair 6 System time the current system time 7 Battery status Indicates the current battery status 8 Manua auto enhancement mode choose manua or auto mode 9 Min tempe...

Page 19: ...s Sub menu interface www amperis com 19 support info amperis com t 34 982209920 OPERATION Shortcut key interface No Name Description 1 Figure name Disp ays the name of the dia og box The name of the d...

Page 20: ...ress the Enter key the following dialog box pops up If choosing www amperis com 20 support info amperis com t 34 982209920 OPERATION Measurement Object Adding Note When deleting a single temperature m...

Page 21: ...select video and press the Enter key as shown below Press stop key to end the recording and return to the current operation status www amperis com 21 support info amperis com t 34 982209920 OPERATION...

Page 22: ...3 as followed Continuous photos mark will appears in the status column if set the continuous photo 2 1 4 www amperis com 22 support info amperis com t 34 982209920 2 2 2 2 2 2 2 1 1 1 1 1 4 OPERATION...

Page 23: ...www amperis com 23 support info amperis com t 34 982209920 OPERATION Settings...

Page 24: ...p the General Settings dialog box The user can set the automatic zero interval 0 5 3 unit setting distance unit setting and external video output switch Press the up and down arrow keys to switch the...

Page 25: ...ic calibration interval to get a better thermal image improve the accuracy of temperature measurement The time unit is seconds www amperis com 25 support info amperis com t 34 982209920 OPERATION Gene...

Page 26: ...of area 1 It will add or remove the area 1 When select shortcut key of record It starts to record When select shortcut key of photo It starts to save the photos you took Screen off and power off If w...

Page 27: ...o off time include laser and LED auto off time used for auto off when the laser or LED turn on the default time is 60s www amperis com 27 support info amperis com t 34 982209920 OPERATION General sett...

Page 28: ...www amperis com 28 support info amperis com t 34 982209920 OPERATION General setting...

Page 29: ...up and down arrow keys to switch the items left and right arrow keys to set the project content that there are subordinate menu press the right button to enter Mode set the infrared camera temperature...

Page 30: ...ject temperature the temperature target displays the ob ject temperature in the bottom right corner www amperis com 30 support info amperis com t 34 982209920 OPERATION General setting Temperature mea...

Page 31: ...If it is not set then will use default setting Attached Common emissivity table for reference Correct the target Temperature Setting the distance between the camera and the target to make sure exact m...

Page 32: ...will automatically adjust the image hierarchy If select Auto Enhancement both High temp target and low temp target can be viewed in the image If select Manual mode User can set the pallet value to adj...

Page 33: ...alarm color set when the temperature is over the alarm temp 9 color types can be selected If colorless is selected then the color will not change when alarm Setting alarm Temperature Only functioned...

Page 34: ...rt info amperis com t 34 982209920 IR IR F Fus usio ion n Hi H gh g Low temperatu ture re M Men e u IR IR IR IR F Fus usio ion High L Low ow w t t t tem m em empe pe pe p ra ratu t re e It con i i i s...

Page 35: ...rk segment 3 Divide the segment of the sub network Set the gateway address to realize the communication among differ ent segment Default 10M 100M Adaptive 10M 100M www amperis com 35 support info ampe...

Page 36: ...oad SD card Format This function is used to format the SD card Select the formatting options pressing the www amperis com 36 support info amperis com t 34 982209920 Unload Unload SD D ca card rd Form...

Page 37: ...inds of annotations audio annotations and text annotations Audio annotations is to add voice when you save the picture text annota tion is to add text messages when save the image CS Shots Set Continu...

Page 38: ...er Language Set the languages 3 Customer can via the Time Setting manu to set the thermal imaging camera s time After the setting the data the time will be saved Users can customize to set the year mo...

Page 39: ...more than 20 words After the import is complete restart the instrument to take effect TF card make sure the SD card is in the machine then select the menu and then click the Export button to export t...

Page 40: ...select ed press the OK button to enter the playback Pressing the C key to exit open image and return to the measurement state The image playback interface Via the left right key to select the play but...

Page 41: ...1 2 will also be deleted then press the C key to undelete www amperis com 41 support info amperis com t 34 982209920 OPERATION General setting File management Delete Note...

Page 42: ...matically Battery is out of power Change battery AutoOffTime option is enabled Set as None Battery depletion is too fast Environmental temperature is too low Rechargeable battery is not charged comple...

Page 43: ...0 0 85 Steel Oxidized 200 0 79 Common brick Surface 20 0 93 Concrete Surface 20 0 92 Glass Polished plate 20 0 94 Lacquer White 100 0 92 Black 100 0 97 Carbon Smoke black 25 0 95 Candle soot 20 0 95 R...

Page 44: ...lor Off Isotherm Temp 51 0 C Isotherm Width 49 0 C Table 4 System setting table Parameter 9 Language English Auto calibration 60S LCD brightness 80 Video Mode NTSC StandbyTime 5 mins AutoOffTime 15 mi...

Page 45: ...AMPERIS PRODUCTS info amperis com www amperis com Copyright 2007 Amperis Products S L Dir C Barbeito Maria 14 27003 Lugo Spain F 34 982 20 99 11 T 34 982 20 99 20...

Reviews: