WTB analyser 

Operation manual 

Version 1.00 

 

Summary of Contents for RRU-WTB/AN01

Page 1: ...rru wtban01_g_en_100 RRU WTB AN01 WTB analyser Operation manual Version 1 00...

Page 2: ...ext all pages must be copied without any changes 2 All redistributed copies must retain the AMiT spol s r o copyright notice and any other notices contained in the documentation 3 This document must n...

Page 3: ...upply 16 6 1 Powering from DC network 16 7 Communication lines 17 7 1 WTB 17 7 1 1 WTB line state indication 18 7 2 Ethernet 19 7 2 1 Ethernet line state indication 20 8 Indications and settings 21 8...

Page 4: ...wtban01_g_en_100 pdf Author Ji B ezina Revision Date Changes 100 14 8 2014 New document Related documentation 1 Programmers manual WTB analyser Programmer s manual file tcn wtb an_ms_en_xxx pdf 2 Appl...

Page 5: ...01 5 28 rru wtban01_g_en_100 1 Definition of used abbreviations Bus Administrator Electric Middle Distance Medium Attachment Unit To Be Defined Train Communication Network Wire Train Bus BA EMD MAU TB...

Page 6: ...ion 1 and 2 are disconnected Terminating resistors are connected in both directions Intermediate Setting The node in this state is physically connected in the middle of WTB line The main MAU channel i...

Page 7: ...intended to be mounted in to the 19 subrack or it could be mounted in to other suitable frame structure Analyser is equipped with doubled WTB interface and working Ethernet line with M12 connector 1...

Page 8: ...of interfaces 1 Operation indication 2 LED LNK and ACT Galvanic separation Yes 1000 V AC 1 minute 1 Data transmission rate 100 Mbps Recommended cabling UTP CAT5 Maximum segment length 100 m Operation...

Page 9: ...5 EU ROHS 1907 2006EU REACH Operating temperature range 40 C to 70 C Operating temperature range 40 C to 70 C Maximum ambient humidity 95 non condensing Reliability MTBF min 180 000 at 40 C ambient te...

Page 10: ...plications Communications signalling and processing systems Software for railway control and protection systems The equipment meets the SIL0 classification according to EN 50129 2003 Railway applicati...

Page 11: ...RRU WTB AN01 11 28 rru wtban01_g_en_100 4 1 Dimensions 142 139 168 5 171 204 129 33 Fig 1 Analyser mechanical dimensions...

Page 12: ...nded drawing symbol Following drawing symbol is recommended for RRU WTB AN01 module X1 24 V WAGO 769 663 RRU WTB AN01 X2 X3 X4 X5 X6 Ethernet M12 WTB A1 D sub DE 9 WTB A2 D sub DE 9 WTB B1 D sub DE 9...

Page 13: ...4 3 Block diagram FPGA Power supply DDR2 WTB interface Ethrenet interface X2 X3 X4 X5 X6 WTB A1 WTB A2 WTB B1 WTB B2 Ethernet 2 5 V ss 1 8 V ss 1 2 V ss X1 Power 24 V ss Power supply 5 V ss 5 V ss Fi...

Page 14: ...munity test aerial discharge Complies 16 kV EN 61000 4 3 2006 Electromagnetic compatibility EMC Part 4 3 Radiated radio frequency electromagnetic field immunity test 800 MHz to 1000 MHz Complies 20 V...

Page 15: ...t 4 29 Testing and measurement techniques Voltage dips short interruptions and voltage variations immunity tests S2 C1 C2 EN 60068 2 1 2007 Environmental testing Part 2 1 Test Test A Cold Complies EN...

Page 16: ...cle on board network 6 1 Powering from DC network Power supply is connected to X1 WAGO 769 663 X COM plug Fig 4 Power supply connector location Connector WAGO 769 663 003 000 Terminal Signal Signal wi...

Page 17: ...DE 9 connectors Connectors are fitted with M3 threaded nuts that secures cable against extraction or falling off due to vibrations Fig 5 Location of WTB line connectors Connector type D sub DE 9 plug...

Page 18: ...A six LEDs in WTB B area indicate the state of line B and remaining four LEDs indicate the node state Following table describes meaning of the individual LEDs Fig 6 LEDs front panel detail WTB LED Co...

Page 19: ...he WTB analyser to connect to LAN network Ethernet interface is fitted with M12 connector according to IEC 61375 3 4 2014 Fig 7 Location of Ethernet line connector M12 type connector according to EN 6...

Page 20: ...ndication Indication of Ethernet line state is provided by two LEDs located above the RJ45 connector Fig 8 Front panel LEDs detail Ethernet LED Color Meaning LNK Green Analyser connected to the Ethern...

Page 21: ...orks faultlessly Analyser goes to Error state in following cases WTB configuration is missing or can not be read Invalid Ethernet configuration Application start failed Occurrence of another error in...

Page 22: ...store the factory setting press and hold the RSTR button while gateway starts up First the S1 LED goes ON and after cca 5 sec starts to blink Release the button when S1 LED starts to blink After setti...

Page 23: ...nel 127 122 4x A A Fig 10 Mounting into 19 subrack If needed analyser can be mounted in a suitable frame In case of mounting into the frame four screws with M3 thread are used not included In this cas...

Page 24: ...t least 70 mm in front of WTB gateway for attaching the cables It is very important to ensure that ambient temperature does not exceed the allowed limits At the same time it is necessary to ensure tha...

Page 25: ...nal of power supply connector must be connected with local installation earthing terminal Minimum cross section of supplying conductors must be at least 0 75 mm2 All cabling must be carefully tied by...

Page 26: ...ng contacts to 21038821405 for AWG 24 28 CAN 09F MC A WTB line connector counterpart D sub DE 9 M3 crimping pins metal cap socket CAN 09M MC A WTB line connector counterpart D sub DE 9 M3 crimping pin...

Page 27: ...e after time with regard to way of using it is necessary to remove dust from device The equipment can be cleaned in cut off state and disassembled by dry paintbrush or fine brush alternatively by vacu...

Page 28: ...sposal The disposal of WTB analyser is subject to the regulations on handling electrical waste Analyser must not be disposed together with common public waste It must be delivered to places specified...