background image

LED Indoor Luminaires 
Wall Mount 
120VAC / 60Hz

 

Page 1 of 2

 

 

 

 

 

 

 

 

 

 

 

 

 

8061002 R3

 

Model #: NVS5131200L30D1xx 

Model #:

 NVV5xxxx00L30D1xx 

 

Limited Factory Warranty 
AFX Inc. hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under normal operating 
conditions for a period of 5 years from date of shipment from factory. This warranty covers all component parts and extends only to replacement of 
defective fixture or components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit. 

24” version shown for 
reference only. Individual 
models may vary. 

Safety Precautions 

 

Read all safety precautions and installation instructions carefully before installing or servicing this fixture. Failure to comply with these instructions could result 
in potentially fatal electric shock and/or property damage.  

 

It is recommended that a qualified electrician perform all wiring. This fixture must be wired in accordance with all national and local electrical codes. 

 

Do not handle any energized fixture or attempt to energize any fixture with wet hands or while standing on a wet or damp surface or in water. 

 

This fixture is designed for use in a 120VAC, 60Hz fused circuit only. This fixture is compatible with a TRIAC (forward-phase or leading-edge) / ELV (reverse-
phase or trailing-edge) dimmer. 

 

To reduce the risk of electrical shock, and to assure proper operation, this fixture must be adequately grounded. To accomplish proper grounding, there must 
be a separate ground wire (green) contact between this fixture and the ground connection of your main power supply panel.  

 

This fixture is intended to be used for general indoor lighting in dry or damp locations.

 

 

Disclaimer 
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: 
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and Canadian ICES-
005 (B) / NMB-005 (B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment 
generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to 
radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures: 

• Reorient or relocate the receiver antenna. 
• Increase the separation between the equipment and receiver. 
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 
• Consult with the dealer or an experienced radio/TV technician for help. 

Any modifications to this fixture may void the warranty and interfere with the safe operation of the luminaire.  
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including 
interference that may cause undesired operation of the device.

 

Assembly Instructions

 

Step 1 

– Preparing for installation

A. 

Disconnect electrical power

 at fuse or circuit breaker box before installing or servicing any part of this fixture. 

B.  Carefully remove the fixture from the carton, remove components from hardware kit. 
C.  Install mounting bracket (2) to the junction box (not included) using two screws (3) to secure it. 

For 3’ and 4’ fixtures, 

install two wood screws through the outer slots into drywall anchor for addition support.

 

Wiring 

– All wiring must take place inside junction box (not included) 

Caution:

 Make sure power is off at fuse or circuit breaker box. Check power wires for damage or scrapes. If power 

supply wires are within three inches of the LED driver, use wire suitable for at least 90°C (194°F).

 

Note:

 Most 

dwellings built before 1985 have supply wire rated to 60°C. Consult a qualified electrician to ensure correct branch 

circuit conductor before installing.

 

 

Step 2 

– Wiring fixture 

A.  Make all wire connections to appropriate wire. Secure with wire nuts (provided).  
B.  Connect the green wire from the fixture to the supply power source ground wire. 
C. 

For none-dimming fixture.

 Connect the white wire from the fixture to the white (N) wire from supply power source. 

Connect the black fixture wire to the black (L) wire from supply power source. 

D. 

For TRIAC dimming.

 Connect the white wire from the fixture to the white (N) wire from dimming source per dimmer 

wiring instructions. Connect the black wire from the fixture to the black (L) wire from dimmer supply power source per 
dimmer wiring instructions. 

E. 

Do not mix wires.

 Pull on each wire lead to make sure connections are secure. Make certain no  

bare wires are exposed outside of wire connectors. Tuck all connections neatly into the junction box. 

Step 3 

– Mounting fixture

 

 

A.  Install fixture (1) to mounting bracket by aligning the two pins on the fixture with the two slots on the bracket (2). Shift 

fixture into the slots to align the mounting holes and secure fixture with two screws (4). 

Step 4 

– Restore power at fuse or circuit breaker box.

 