background image

 

Aerospace Logic Inc. 

Tel. 416-628-0725 

www.aerospacelogic.com

This document set is applicable to the following part number configurations: 

Part Number 

Description 

FL202 

Fuel level instrument, two tanks, 

resistive senders 

Part Number 

Description 

FL203 

Fuel level instrument, three tanks, 

resistive senders 

Part Number 

Description 

FL204 

Fuel level instrument, four tanks, 

resistive senders 

Part Number 

Description 

FL205 

Fuel level instrument, five tanks, 

resistive senders 

Part Number 

Description 

FL206 

Fuel level instrument, six tanks, 

resistive senders 

Summary of Contents for FL202

Page 1: ...level instrument two tanks resistive senders Part Number Description FL203 Fuel level instrument three tanks resistive senders Part Number Description FL204 Fuel level instrument four tanks resistive...

Page 2: ...tensity Control Installation Options S200 DDC INST Wiring and Installation Schematic S200 FL20X 003 Human Interface Definition S200 HID Instrument Setup S200 FL20X 004 Operations Guide S200 FL20X 005...

Page 3: ...he Approved Model List USA and all other countries If it is NOT listed contact your local authority and obtain the necessary requirements or approvals before proceeding further For all other vehicles...

Page 4: ...e will pay for the shipping costs to return the instrument to you Replace all instruments that fail out of warranty for a flat rate of 50 of the cost of a new instrument at the time of the failure We...

Page 5: ...c DO NOT ATTACH THE CONNECTOR TO THE INSTRUMENT UNTIL ALL WIRING HAS BEEN CONNECTED 3 Select the instrument location in the aircraft panel 4 Ensure that the aircraft master switch and or power to the...

Page 6: ...will vary the display intensity 1 Preferred Method Independent Potentiometer Connect the BLUE wire to P N A200 POT Rev 02 as below Ensure the EXTERNAL option in the Dimmer Control menu is set 2 Conne...

Page 7: ...ow for current drain of 0 1A 100mA Install using breaker or panel fuse Maximum 7 instruments per 1A of breaker capacity For multiple instrument installations install breakers to comply with redundancy...

Page 8: ...e selections Examples of these actions are 1 Selection of different cylinders EGT and CHT in the Single Cylinder mode 2 Selection of different tanks Fuel Level 3 Selection of limits and functional ite...

Page 9: ...ll function To calibrate each tank you will be required to add fuel at TWO gallon increments starting with the unusable fuel in the tank the legal zero fuel point a Place the aircraft in a level fligh...

Page 10: ...e setup menus use the bottom button to navigate and the top button to select an option e Follow the onscreen instructions to enter the correct operating parameters NOTE Depending on the installation o...

Page 11: ...the fuel level in each tank Colors are determined by the range values as set during installation Tanks are indicated from leftmost to rightmost For the FL202 instrument the quantity in each tank is p...

Page 12: ...information press and hold the bottom button when the instrument is first powered on WARNING NEVER RELY SOLELY ON ANY FUEL INDICATION INSTRUMENT FOR THE DETERMINATION OF AVAILABLE FUEL WHEN USED IN C...

Page 13: ...g 1hr 40 C to 70 C Storage 55 C to 85 C Signal Input Sender resistance 0 25 to 300 Sender Orientation Installer selectable Resistance proportional or Inversely proportional to fuel quantity Display Fu...

Page 14: ...n As primary replacement products it is recommended and preferred that they be placed in the same panel location as the original equipment Their visibility and placement relative to other instruments...