Protect 

3.M 2.0 

Modular uPs systeM

Uninterruptible Power Supply

3-Phase Input; 3-Phase Output

20 –120 kVA power supply 

Networks, workstations, intranet and internet servers, 

telecommunications applications and other company 

applications must be permanently available. AEG 

Protect 3.M 2.0 is the modular UPS solution for IT and 

telecommunications. Modern data centers require the 

highest levels of efficiency, reliability and flexibility. 

Protect 3.M 2.0 provides a technically convincing 

and reliable solution to this requirement that can be 

modularly adapted to any increasing power demand.

An extension can be made at any time during 

operation. The flexible redundancy concept ensures a 

steady power supply to any connected devices.

Lower operating costs for energy and cooling with high 

efficiency and fast module replacement in the event of power 

failure, reduce operational costs and ensure an optimal price 

vs. performance ratio for the Protect 3.M 2.0 UPS solution.

Key features

 

»

Modular design allows for flexible adaption 

to the current power demand

 

»

Up to 95 % efficiency in “online double conversion” 

mode, up to 98 % in ECO mode

 

»

IGBT technology, input power factor >0.99

 

»

Low phase effect <3 %

 

»

Redundant control and n+x parallel 

redundancy for high availability

 

»

Parallel operation of up to 4 UPS units (max. 480 kVA)

 

»

Module installation and removal during operation  

(”hot swappable”)

 

»

Graphical LCD screen

 

»

Built-in manual bypass, separate input for bypass power

 

»

Load dependent fan speed

 

»

Small footprint

Summary of Contents for Protect 3.M 2.0

Page 1: ...The flexible redundancy concept ensures a steady power supply to any connected devices Lower operating costs for energy and cooling with high efficiency and fast module replacement in the event of power failure reduce operational costs and ensure an optimal price vs performance ratio for the Protect 3 M 2 0 UPS solution Key features Modular design allows for flexible adaption to the current power ...

Page 2: ...pts the permitted UPS power according to your current power needs This can be done without additional installation costs since the power modules can be easily inserted and are automatically recognized by the system hot swappable No additional connections are required for this operation Dynamic redundancy An automatic load balancing to all modules within an appropriately designed system delivers N ...

Page 3: ...d current Admissible power factor 0 1 inductive to 0 1 capacitive Battery Rated voltage 240 V DC Max charging power 5 A 10 A 15 A 20 A 25 A 30 A Charging principle Load switching per power module Autonomy time Selectable over external battery cabinet Static bypass Nominal voltage 3 x 400 V 380 415 V adjustable 3 phase neutral Frequency 50 Hz 60 Hz adjustable Synchronization range 0 1 5 adjustable ...

Page 4: ...ignal contacts MODBUS extension card and SNMP adapter Battery Management Each UPS power module contains its own battery charger with intelligent charging electronics These can be adapted to the battery in use and facilitate the use of vendor independent standard batteries A temperature compensated charging curve ensures an optimum charging regime Automatic testing informs you of the charging state...