background image

OWNER'S

OPERATING

MANUAL

Isolated Uninterruptible Power Supply Models:

SG2K-X1T
SG2K-X2T
SG3K-X1T
SG3K-X2T

Detailed SG Series product specifications are available in PDF format at 

www.falconups.com

®

2006 Falcon

®

Electric Inc. All rights reserved.

All other brand names and trademarks are the property of their respective owners.
The information stated in this document is subject to change without notice.  2006-02-24
Falcon

®

, Falcon® Electric and UPS Plus logos are registered trademarks of Falcon Electric Inc

Rev. F

FALCONElectric Inc., 5116 Azusa Canyon Rd., Irwindale, California  91706, (626) 962-7770, Fax 626-962-7720, Email: [email protected]

Summary of Contents for SG2K-X1T

Page 1: ...ic Inc All rights reserved All other brand names and trademarks are the property of their respective owners The information stated in this document is subject to change without notice 2006 02 24 Falco...

Page 2: ...3 Operation 10 Front Panel Indicators Function Key Diagram 10 Front Panel Function Description 10 Audible Alarms 12 Category One Alarms 12 Category Two Alarms 12 Chapter 4 Rear Panel Details 13 SG2K X...

Page 3: ...On Line Design Input Power Factor Correction Wide Input Voltage Window Pure Sinewave Output Precision Output Voltage Regulation Superior Brownout Surge and Transient Protection Internal System Bypass...

Page 4: ...r supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing the UPS batteries use the same number and type of batte...

Page 5: ...s feature provides the following benefits Breaks neutral to ground current and noise paths Greatly reduces common mode noise Gives a superior level of protection against high frequency noise and trans...

Page 6: ...ter recharging Please specify your extended battery and charger requirements at the time of your initial order Frequency Converter Option With a factory modification at the time of order any SG Series...

Page 7: ...own or to the enabled position the Green Mode function is activated When the load connected to the output of the UPS drops to under 10 of the full rated UPS output for 30 seconds the UPS is automatica...

Page 8: ...T BE INSTALLED IN AN ENCLOSED AREA 11 Plug the UPS power cord into the nearest grounded wall outlet 12 Turn the input circuit breaker located on the UPS rear panel to the on position The internal UPS...

Page 9: ...default Up Up 115V SW2 SW1 VOLTAGE Down Down 220V Down Up 230V Factory Default Up Down 240V Up Up 200V SW3 FUNCTION Down GREEN MODE ON Up GREEN MODE OFF SWITCH SETTINGS FOR 1 MODELS SWITCH SETTINGS FO...

Page 10: ...m the following a Verify the battery charger circuit breaker is in the off down position b On the battery bank nameplate label located on the rear panel verify the battery charger input voltage matche...

Page 11: ...5Vdc 4A 82 5Vdc 4A 82 5Vdc 4A 82 5Vdc 4A OF CHARGERS 1 1 1 1 2 3 FOR 2KVA MODELS BATTERY OPTION MODELS W O Charger SGB2S7 3K3 SGB2S7 3K3 SGB5S7 3K6 SGB2S7 3K3 SGB5S7 3K6 SGB5S7 3K6 BATTERIES 16 Pieces...

Page 12: ...Second LED is let when the battery level is above the low battery warning Level The first LED is lit when the battery level is above the battery cutoff voltage 3 LINE SITE WIRING FAULT INDICATOR LED F...

Page 13: ...he following describes the different modes of operation for this button a Depressing this button when the UPS is off and the utility voltage is not present or with the UPS input circuit breaker in the...

Page 14: ...TEST BUTTON DEPRESSED 2 Category two alarms a Three short beeps indicate the SG UPS output voltage is out of proper operating range SG UPS OUTPUT VOLTAGE IS OUT OF PROPER RANGE b Four short beeps indi...

Page 15: ...her Configurations COVER PLATE FOR OPTIONAL SNMP AGENT DIP SWITCHES RS 232 CONNECTOR COOLING FANS DO NO BLOCK MAIN POWER SWITCH INPUT CIRCUIT BREAKER LINE CORD INLET OUTPUT FUSES 2 places OPUTPUT RECE...

Page 16: ...the green cable supplied with the UPS There are communications options that WILL DISABLE the RS 232 port and render it inoperable The options are as follows a Internal SNMP HTTP agent option installe...

Page 17: ...ommons JP3 open Alarm common only PIN JUMPER ASSIGNMENT FOR THE FALCON UA88374 RELAY OPTION BOARD no on bypass signal PIN JUMPER ASSIGNMENT FOR THE FALCON UA88376 RELAY OPTION BOARD with on bypass sig...

Page 18: ...upon utility loss 4 Common for pins 2 3 5 5 Low Battery N O Closes at low battery 6 Remote Shutdown Applying a 5 12Vdc voltage level for 500ms while the UPS is on battery will shutdown the UPS 7 Not U...

Page 19: ...Shutdown on battery operation only 2 Remote Shutdown Common 3 Not Used 4 Low Battery Common 5 Low Battery N O 6 Not Used 7 Not Used 8 Utility Fail 10Vdc 9 Utility Fail 10Vdc PIN JUMPER ASSIGNMENT FOR...

Page 20: ...Falcon Service Department see page 20 for contact information Never attempt to service batteries High voltage exists within the unit which could cause electrical shock Servicing of batteries should b...

Page 21: ...l interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the inst...

Page 22: ...eturning any SG Series product Falcon Electric will not assume any responsibility for shipping damage In the event of shipping damage you will be notified of the damage and be instructed to file a cla...

Page 23: ...NY IMPLIED WARRANTY OF MERCHANTABILITY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND EXPRESS WARRANTIES THAT THIS PRODUCT WILL CONFORM TO ANY AFFIRMATION OR PROMISE FOR THIS PRODUCT AND THE...

Page 24: ...se 4ms After Overload Auto Transfer to UPS Electrical Connections Input 6 Cord with 5 20P Detachable 6 Line Cord with a L6 20P or Schuko 6 Cord wit L5 30P Detachable 6 line cord with a L6 20P or Schuk...