background image

ENCORE Z7LP

User Manual

Summary of Contents for ENCORE Z7LP

Page 1: ...ENCORE Z7LP User Manual...

Page 2: ...ding and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the...

Page 3: ...es 6 Safety Guidelines 7 Overview 8 Installation 9 Remote Device Management RDM 14 Wifly Control 15 System Menu 16 DMX Setup 19 DMX Traits 21 Color Macros Chart 23 Dimmer Speeds 24 Dim Modes 25 Daisy...

Page 4: ...t team for further instructions Please do not return this device to your dealer without first contacting customer support Please do not discard the shipping carton in the trash Please recycle whenever...

Page 5: ...repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof includ...

Page 6: ...e Lime Intended for dry indoor usage only it offers 16 bit fine RGBL color control and 64 built in color macros as well as 6 DMX channel mode options RDM and flicker free operation INCLUDED ITEMS Powe...

Page 7: ...METERS MAXIMUM AMBIENT TEMPERATURE IS 113 F 45 C DO NOT OPERATE THE DEVICE WHEN AMBIENT TEMPERATURE EXCEEDS THIS VALUE MINIMUM DISTANCE TO FLAMMABLE MATERIALS FROM THE SURFACE IS 1 6 FEET 0 5 METER DO...

Page 8: ...ting Bracket Gel Filter Slot Lens Frame Latch Mounting Bracket Adjustment Knob Safety Cable Loop DMX Out DMX In Enter Button Up Button Down Button Mode Button Power Out Power In Fuse Display Screen OV...

Page 9: ...the combined weight of the xture s clamps cables and accessories Maximum fixture ambient operating temperature is 113 F 45 C Do not use operate the fixture when ambient temperature exceeds this value...

Page 10: ...ation below When mounting the fixture to a truss or any other suspended or overhead installation be sure to secure an appropriately rated clamp not included to the bracket and attach a separate SAFETY...

Page 11: ...the mounting yoke Tighten the nut onto the threaded bolt to secure the mounted device in place CAUTION MAKE SURE THAT THE TRIPOD LEGS AND ALL TELESCOPING ELEMENTS OF THE TRIPOD STAND ARE LOCKED IN PL...

Page 12: ...shutters motors belts wiring discharge lamps and LEDs This issue is not unique to ADJ lighting fixtures but rather it is a common issue with lighting fixtures from all manufacturers Although there is...

Page 13: ...he below right image Close the latch to secure the gel frame in place ACCESSORY INSTALLATION BARNDOOR In order to install the optional barndoor find the latch located at the top of the lens frame Open...

Page 14: ...ould typically have to be changed or viewed directly via the unit s display screen including the DMX Address DMX Channel Mode and Temperature Sensors Please be aware that not all RDM devices support a...

Page 15: ...e the chances of having a clear path for the wireless signal to reach the device Install the device a minimum of 9 8 ft 3m above audiences and or ground level Arrange the wireless antenna in an uprigh...

Page 16: ...or confirm selection DISPLAY SCREEN LOCK When the Display Lock setting is set to 1 10min the display screen will automatically lock if there is no activity for the specified length of time To unlock t...

Page 17: ...i Theatre Stage 2 Preset dim modes see Dim Modes diagram DimSpeed 0 1S 10s Set dim delay from 0 1s to 10s Dim Curve Square Linear Inv Squa S Curve LEDRfrsh 900 1000 1100 1200 1300 1400 1500 2500 4000...

Page 18: ...Hr1 xxxxxx Hours Total hours fixture powered ON Cannot be reset PwrOnHr2 xxxxxx Hours Current of hours fixture has been powered ON since last reset Can be reset back to zero by user PwrOnRst Passcode...

Page 19: ...re is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Oper...

Page 20: ...correct control signal This digital starting address is the channel number from which the fixture starts to listen to the digital control signal sent out from the DMX controller The starting DMX addre...

Page 21: ...trobe effect slow to fast 096 127 Led s On 128 159 Pulse effect in sequences 160 191 Led s On 192 223 Random strobe effect slow to fast 224 255 Led s On 6 9 9 9 000 255 Dimmer Intensity 0 to 100 7 10...

Page 22: ...d from Fast to Slow 0 1 10s 161 255 Default to Unit Setting 14 17 Dim Curves 0 20 Square 21 40 Linear 41 60 Inv Squa 61 80 S Curve 81 255 No Function 15 18 Refresh Rates 0 15 Default to Unit Setting 1...

Page 23: ...14 53 56 255 93 182 93 Color Macro 47 185 188 0 142 208 0 Color Macro 15 57 60 255 96 236 96 Color Macro 48 189 192 52 148 209 0 Color Macro 16 61 64 238 93 255 93 Color Macro 49 193 196 1 134 204 0 C...

Page 24: ...TIME 141 0 1 s 142 0 2 s 143 0 3 s 144 0 4 s 145 0 5 s 146 0 6 s 147 0 7 s 148 0 8 s 149 0 9 s 150 1 0 s 151 1 5 s 152 2 0 s 153 3 0 s 154 4 0 s 155 5 0 s 156 6 0 s 157 7 0 s 158 8 0 s 159 9 0 s 160 1...

Page 25: ...25 DIMMER MO DES...

Page 26: ...the xture operates damp smoky or particularly dirty environments can cause greater accumulation of dirt on the xture s optics Clean the external lens surface periodically with a soft cloth to avoid di...

Page 27: ...ge TV Architectural Theatre Stage 2 4 selectable Dim Curves Linear Square Inv Squa S Curve Adjustable Refresh Rate 14 presets from 900 25 000Hz Flicker Free operation No flickering on camera LED pulse...

Page 28: ...28 11 1in 281 0mm 9 2in 233 0mm 13 2in 335 9mm 9 2in 233 0mm 14 8in 376 0mm 8 1in 205 1mm 11 5in 292 5mm 6 3in 160 5mm 7 9in 201 7mm DIMENSIO N DRAW I N GS...

Page 29: ...erence to radio communications However there is no guarantee that interference will not occur in a particular installation If this device does cause harmful interference to radio or television recepti...

Page 30: ......