background image

User Manual

POWER BONE T1ED

EXTEND YOUR WORLD...

TM

Summary of Contents for ACCU-CABLE POWER BONE T1ED

Page 1: ...User Manual POWER BONE T1ED EXTEND YOUR WORLD TM ...

Page 2: ...ent building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and opera tion of this product Europe Energy Saving Notice Energy Saving Matters EuP 2009 125 EC Saving electric energ...

Page 3: ... F C O N T E N T S General Information 4 Key Features Warranty Returns 5 Limited Warranty USA Only 6 Safety Guidelines 7 Overview 9 Installation 10 Cleaning Maintenance 13 Dimensional Drawings 14 Specifications 15 ...

Page 4: ...cting customer support Please do not discard the shipping carton in the trash Please recycle whenever possible INCLUDED ITEMS Omega Bracket x1 Power Cable x1 CUSTOMER SUPPORT Contact ADJ Service for any product related service and support needs Also visit forums adj com with questions comments or suggestions ADJ SERVICE USA Monday Friday 8 00am to 4 30pm PST 323 582 2650 Fax 323 832 2941 support a...

Page 5: ...nder warranty you must pro vide a copy of your proof of purchase invoice You may obtain an R A number by contacting our cus tomer support team All packages returned to the service department not displaying an R A number on the outside of the package will be returned to the shipper Daisy chain linking capability to get power where you need it Outdoor power locking input connection to supply main po...

Page 6: ...es for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of ADJ Products LLC All products covered by this warranty were manufactured after August 15 2012 and bear identifying marks to that effect ...

Page 7: ...e event of an internal short Disconnect from main power before making any type of connection This flight case and charging system are intended for indoor use only Use of these devices outdoors voids all warranties Always mount this unit in a safe and stable matter Please route your power cord out of the way of foot traffic Power cords should be routed so they are not likely to be walked on or pinc...

Page 8: ...to the fixture and or the included mounting hardware will void the original manufacturer s warranty and increase the risk of damage and or personal injury PROTECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF DOING SO WILL VOID YOUR MANUFACTURER S WARRANTY DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AN...

Page 9: ...3 4A Max Power In AC 125V 60Hz 15A Max Power Out to Devices AC 125V 60Hz each Max 15A each Power Thru AC 125V 60Hz 15A Max Omega Bracket Mounting Points Power Out to Devices AC 125V 60Hz each Max 15A each Power Indicator Power Indicator Power Indicator ...

Page 10: ...nstalling or mounting any device a professional equipment installer MUST be consulted to determine whether the mounting structure or surface is properly certified to safely support the com bined weight of the fixture clamps cables and accessories Maximum ambient operating temperature range is 95 degrees F 35 degrees C Do not operate the device if ambient temperature exceeds this limit This fixture...

Page 11: ...e rigging clamp to the included Omega Brackets using an M10 screw fitted through the center hole of the Omega Brackets RIGGING Overhead rigging requires extensive experience including but not limited to calculating working load limits understanding the installation material being used and periodic safety inspection of all installa tion material and the fixture itself If you lack these qualificatio...

Page 12: ...ports located on the ends of each Power Bone device Please note that the Power In port is located on the end with the USB ports while the Power Thru port is located by itself on the other end Use caution when linking multiple Power Bone units The number of Power Bone units that can be safely linked is dependent upon the individual power requirements of each device that is connected to the Power Bo...

Page 13: ...rts inside this fixture Please refer all other service issues to an authorized ADJ service technician Should you need any spare parts please order genuine parts from an authorized ADJ dealer Please refer to the following points during routine inspections A detailed electrical check by an approved electrical engineer every three months to make sure the circuit contacts are in good condition and pre...

Page 14: ...14 D I M E N S I O N A L D R AW I N G S Dimensions not to scale 4 7in 120mm 4 7in 120mm 3 0in 75mm 4 4in 112mm 8 9in 225mm ...

Page 15: ...ut and thru connections 4x Seetronic indoor Edison output sockets 2x 5V USB sockets Power indicator LED s for input outputs IP20 rated for dry location use only Power Input 100 240VAC 50 60Hz Maximum Ambient Temperature 95 F 35 C Maximum daisy chain current draw 15 A ...

Page 16: ......

Reviews: