Page 1: ...User Instructions FOCUS SPOT 5Z USA FOC520 EU 123000300 UPC 818651028201 ...

Page 2: ...ct features and or enhancements an updated version of this document may be available online Please check www adj com for the latest revision update of this manual before beginning installation and or programming FCC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device mus...

Page 3: ...ty Guidelines Installation Overview DMX Set Up DMX Addressing DMX Modes Values System Menu Dimmer Mode Chart I Dimmer Curve Chart Dimensional Drawings Gobo Replacement I Gobos Fuse Replacement I Multiple Unit Power Linking Trouble Shooting I Cleaning Limited Warranty USA Only Technical Specifications 3 4 5 8 10 11 13 14 20 26 27 28 29 29 30 31 ...

Page 4: ...ionally trained personnel only and is not suitable for private use Customer Support Contact ADJ Service for any product related service and support needs Also visit forums adj com with questions comments or suggestions Parts To purchase parts online visit http parts americandj com ADJ SERVICE USA Monday Friday 8 00am to 4 30pm PST Voice 800 322 6337 Fax 323 582 2941 support adj com ADJ SERVICE EUR...

Page 5: ...proof of purchase invoice You may obtain a R A number by con tacting our customer support team on our customer support number All packages returned to the service department not displaying a R A number on the outside of the package will be returned to the shipper ADJ Products LLC www adj com Focus Spot 5Z User Manual Page 4 Individual Color and Gobo Wheels 2 x Color Wheels 8 Colors White Each Whee...

Page 6: ...will allow proper ventilation Allow about 6 15cm between this device and a wall During the initial operation of this fixture a light smoke or smell may emit from the interior of the fixture Thsi is a normal process and is caused by excess paint in the interior of the casing burning off from the heat This will decrease gradually over time DO NOT remove the cover under any conditions There are no us...

Page 7: ...OTHING AND OR USING UV PAINTS ON SKIN AVOID DIRECT EYE AND OR SKIN EXPOSURE AT DISTANCES SHORTER THAN 11 feet 3 3m DO NOT OPERATE FIXTURE WITH DAMAGED OR MISSING EXTERNAL COVER DO NOT LOOK DIRECTLY INTO THE UV LIGHT AND OR VIEW UV LIGHT DIRECTLY WITH OPTICAL INSTRUMENTS THAT MAY CONCENTRATE THE LIGHT RADIATION OUTPUT INDIVIDUALS SUFFERING FROM A RANGE OF EYE CONDITIONS SUNLIGHT EXPOSURE DISORDERS ...

Page 8: ...risms animation wheels frost filters iris shutters motors belts wiring discharge lamps and LEDs This issue is not specific only to ADJ lighting fixtures it is a common issue with lighting fixtures from all manufacturers Although there is no true way to fully prevent this issue from happening the guidelines below can prevent any potential damage from occurring if followed Contact ADJ Service for mo...

Page 9: ...the opening located on the base plate and over the trussing system or a safe fixation spot Insert the end in the carabine and tighten the safety screw NOTICE The suitable enviromental temperature for this lighting fixture is between 25 C to 45 C Do not place this lighting fixture in an enviroment where the temperatures are under or above the temperatures stated above This will allow the fixture to...

Page 10: ...e Never use the carrying handles for secondary attachment When installing the unit the trussing or area of installation must be able to hold 10 times the weight without any deformation When installing the unit must be secured with a secondary safety attachment e g and appropriate safety cable Never stand directly below the unit when mounting removing or servicing the unit Overhead mounting require...

Page 11: ...ot 5Z Overview 1 Service Port 2 LED Display 3 Mode Button Up Button Down Button Left Button Right Button Enter Button 4 Locking Power Connector In 5 Fuse Holder 6 Locking 5 Pin XLR Connector Out 7 Locking 5 Pin XLR Connector In 8 Locking Power Connector Out 1 3 2 4 5 6 7 8 ...

Page 12: ... DMX Operation The Focus Spot 5Z can be controlled via DMX 512 protocol The DMX address is set on the front panel of the Focus Spot 5Z Your unit and your DMX controller require a 5 pin XLR connector for data input and data output We recommend Accu Cable DMX cables If you are making your own cables be sure to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all pro ligh...

Page 13: ...ation reduces signal errors and avoids signal transmission problems and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fixture 1 2 3 Figure 3 5 Pin XLR DMX Connectors Some manufactures use 5 pin DMX 512 data cables for DATA transmission in place of 3 pin 5 pin DMX fixtures may be implemented in a 3 pin DMX line Whe...

Page 14: ...ting all fixtures to the same DMX address will cause all fixtures to react in the same way in other words changing the settings of one channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will start to listen to the channel number you have set based on the quantity of DMX channels of each fixture That means changing the settings of one ch...

Page 15: ...low Fast 000 007 008 014 015 021 022 028 029 035 036 042 043 049 050 056 057 063 064 127 128 189 190 193 194 255 000 255 000 255 000 255 000 255 Basic 19 3 1 2 COLOR WHEEL 2 Open White Lavender Blue CTB 5600 Green Yellow UV CTO 3200 Pink Color Indexing Clockwise Rotation Fast Slow Stop Counter Clockwise Rotation Slow Fast 000 007 008 014 015 021 022 028 029 035 036 042 043 049 050 056 057 063 064 ...

Page 16: ... 020 034 035 049 050 064 065 079 080 094 095 109 110 124 125 139 140 154 155 169 170 189 190 221 222 223 224 255 5 8 8 6 GOBO ROTATION Indexing Clockwise Rotation Fast Slow No Rotation Counter Clockwise Rotation Slow Fast 000 127 128 189 190 193 194 255 SHUTTER STROBE Shutter Closed Shutter Open Strobe Slow Fast Shutter Open Pulse Effect Slow Fast Shutter Open Random Strobe Slow Fast Shutter Open ...

Page 17: ... 16 BIT 000 255 13 15 14 16 12 17 11 FOCUS Far Near 000 255 ZOOM Minimum Maximum Beam 000 255 FROST 1 0 100 000 255 FROST 2 0 100 000 255 15 18 13 16 19 14 21 18 22 16 17 15 ZOOM FINE INDEXING 16 BIT 000 255 20 Functions Standard 22 Extend 26 Values Basic 19 PRISM 1 6 FACET CIRCULAR Open Shutter Open 000 031 032 255 PRISM 1 INDEXING ROTATION Indexing Clockwise Rotation Fast Slow No Rotation Counte...

Page 18: ... 21 25 18 Functions Standard 22 Extend 26 Values Basic 19 DIMMER MODES Standard Stage TV Architectural Theatre Stage 2 DIMMING SPEED 0 1Sec 0 2Sec 0 3Sec 0 4Sec 0 5Sec 0 6Sec 0 7Sec 0 8Sec 0 9Sec 1 0Sec 1 5Sec 2 0Sec 3 0Sec 4 0Sec 5 0Sec 6 0Sec 7 0Sec 8 0Sec 9 0Sec 10Sec Default to Unit Setting 000 020 021 040 041 060 061 080 081 100 101 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 ...

Page 19: ...70 980 990 1000 1010 1020 1030 1040 1050 1060 1070 1080 1090 1100 1110 1120 1130 1140 1150 1160 1170 1180 1190 1210 1220 1230 1240 1250 1260 1270 1280 1290 1300 1310 1320 1330 1340 1350 1360 1370 1380 1390 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 Functions Standard 22 Extend 26 Values Basic 19...

Page 20: ...e Disable Blackout with Gobo Change Reset All Reset Pan Tilt Reset Color Gobo Reset Effect Focus Internal Program 1 Scenes 1 8 Internal Program 2 Scenes 9 16 Internal Program 3 Scenes 17 24 Internal Program 4 Scenes 25 32 Internal Program 5 Scenes 33 40 Internal Program 6 Scenes 41 48 Internal Program 7 Scenes 49 56 Fan Mode Low Fan Mode High Fan Mode Auto No Function 60 61 62 63 64 65 66 67 68 69...

Page 21: ...utton to illuminate the LCD screen until the DMX address is displayed Then navigate to the desired system menu LCD CONTROL PANEL LOCKOUT When the Key Lock function is activated the control panel will automatically lock after the time set under the Display submenu Screen Saver Delay When the Key Lock function is set to ON the control panel will lock Press and hold the MODE button for 3 seconds to u...

Page 22: ...tors Reset Pan Tilt Motors Reset Effect Focus Motors Dim Modes Dimming Modes Dimming Speed Standard Stage TV Architectur Theatre Stage2 Dim Speed 0 1 10s LED Refresh Rate 1200 900 1500 2500 4000 5000 6000 10000 15000 20000 25000 Hz LED Refresh Setting Display Intensity 1 10 Dimmest Brightest Display Invert YES NO Screen Saver Delay OFF 10M Display Intensity Adjustment Display Inversion Display Shu...

Page 23: ... 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 INTERNAL PROGRAMS Program 1 Program 2 Program 3 Program 4 Program 5 Program 6 Program 7 Program 1 with Adjustments Program 2 with Adjustments Program 3 with Adjustments Program 4 with Adjustments Program 5 with Adjustments Prog...

Page 24: ...Power On Time XXXXXX Hours P On Time R XXXXXX Hours P On Time Reset YES NO Pass Code 50 LED On Time XXXXXX Hours LED On Time R XXXXXX Hours LED Hours Reset YES NO Pass Code 50 Error Logs Fixture Errors Reset Error Log Pass Code 50 List of Errors One by One Clear the Error Log Software Version VX X Current Software Version DMX Values Pan Pan Fine Tilt Tilt Fine Color 1 Color 2 Gobo Gobo Rot Shutter...

Page 25: ...le to designate the units as either Master or Slave unit in a master slave set up STATUS SETTINGS In this submenu you are able to access and adjust change Pan Degree Pan Invert Tilt Invert P T Feedback P T Speed and Hibernation FAN SETTINGS In this submenu you are able to select your desired fan speed setting DIM MODES In this submenu you are able to select your desired dimmer mode and adjust the ...

Page 26: ...played time represents the current LED ON time since the last reset LED Hours Reset With this function you can reset the CURRENT LED ON time that is displayed under LED On Time R FIXTURE TEMPS LED s Current The current LED temperature will be displayed Max Resettable The current highest temperature the LED has reached will be displayed This LED temperature may not be the same as the temperature di...

Page 27: ...540 1660 TV 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 Stage 2 0 1100 0 1660 Rise Time ms Down Time ms Rise Time ms Down Time ms Rise Time Down Time Dimming Curve Ramp Effect 0 sec Fade Time 1 sec Fade Time Focus Spot 5Z Dimmer Curve Chart Output 0 100 Output 0 100 Output 0 100 Output 0 100 DMX DMX DMX DMX LINEAR SQUARE INVERSE SQUARE S CURVE ...

Page 28: ...e able to access the gobo wheel Turn the wheel until you come across the gobo you would like to change 3 Once you have found the gobo you would like to change use your finger to carefully turn the small inner gear so that the alignment dot on the inner gear lines up with the gobo you would like to replace Figure 1 4 Once the gobo and alignment dot are lined up CAREFULLY from underneath the gobo wh...

Page 29: ...Manual Page 28 Focus Spot 5Z Gobo Replacement Focus Spot 5Z Gobos GOBO 1 GOBO 5 GOBO 3 GOBO 4 GOBO 2 GOBO 6 FIGURE 1 INNER GEAR ALIGNMENT DOT INNER GEAR FIGURE 2 FIGURE 3 PROTRUDING PIN PROTRUDING PIN INNER GEAR ALIGNMENT DOT INNER GEAR ALIGNMENT DOT ...

Page 30: ...w adj com Focus Spot 5Z User Manual Page 29 Focus Spot 5Z Dimensional Drawing 174mm 6 85 278 61mm 10 97 463 45mm 18 25 333 75mm 13 14 230 36mm 9 07 174mm 6 85 182 37mm 7 18 93 7mm 3 69 107mm 4 21 75 15mm 2 96 NOT TO SCALE ...

Page 31: ...ing 2 Clean the external optics with glass cleaner and a soft cloth every 20 days 3 Always be sure to dry all parts completely before plugging the unit back in Cleaning frequency depends on the environment in which the fixture operates i e smoke fog resi due dust dew Focus Spot 5Z Multiple Unit Power Linking With this feature you can connect the fixtures to one another using the power cable input ...

Page 32: ...ranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of ADJ Products LLC All products covered by this warranty were manufactured after August 15 2012 and bear indentifying marks to that effect E ADJ Pro...

Page 33: ...m Weight 23lbs 10 kgs Colors Color Wheel 1 8 Colors White Color Wheel 2 8 Colors White Gobos 6 Gobos 1 Glass Open Aluminum Gobos Inner Diameter 19mm Outer Diameter 23mm Thickness 0 5mm Glass Gobo Inner Diameter 19mm Outer Diameter 23mm Thickness 3 3mm DMX Channels 3 DMX Modes 19 22 26 Warranty 2 Year 730 days Please Note Specifications and improvements in the design of this unit and this manual ar...