User Manual   

Modbus / CAN - Datalogger 

 

Document code: MN67324_ENG     Revision 1.200    Page 1 of 44 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.200 
English 

 

Modbus / CAN – Datalogger 

 (Order Code:  HD67324-B2-E-232-4GB, HD67324-B2-E-485-4GB, 
HD67324-B2-E-CAN-4GB) 

 
for Website information:  

www.adfweb.com?Product=HD67324

 

 

for Price information: 

www.adfweb.com?Price=HD67324-B2-E-232-4GB

  

www.adfweb.com?Price=HD67324-B2-E-485-4GB

  

www.adfweb.com?Price=HD67324-B2-E-CAN-4GB

  

 

 

Benefits and Main Features: 

 

Very easy to configure 

 

Electrical isolation 

 

Temperature range: -40°C/85°C (-40°F/185°F) 

 

For other M-Bus products: 

See also the following link: 

Converter M-Bus to  

www.adfweb.com?Product=HD67021

   

(RS232)

 

www.adfweb.com?Product=HD67022

   (RS485) 

www.adfweb.com?Product=HD67030

   

(Ethernet) 

 
Extender and Repeater, M-Bus

 

www.adfweb.com?Product=HD67032

 

 

Gateway M-Bus / Modbus RTU  

www.adfweb.com?Product=HD67029M-232

     

(on RS232) 

www.adfweb.com?Product=HD67029M-485

     

(on RS485)

 

 

Gateway M-Bus / Modbus TCP  

www.adfweb.com?Product=HD67044-B2

 

 

Gateway M-Bus / CANopen 

www.adfweb.com?Product=HD67051

 

 

Gateway M-Bus / PROFIBUS 

www.adfweb.com?Product=HD67053M

 

 
Do you have an your customer protocol? 

See the following link: 

www.adfweb.com?Product=HD67003

 

 
Do you need to choose a device? do you want help? 

Ask it to the following link: 

www.adfweb.com?Cmd=helpme

 

 

User Manual   

 

Summary of Contents for HD67324-B2-E-232-4GB

Page 1: ...rical isolation Temperature range 40 C 85 C 40 F 185 F For other M Bus products See also the following link Converter M Bus to www adfweb com Product HD67021 RS232 www adfweb com Product HD67022 RS485...

Page 2: ...OLICY 44 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain th...

Page 3: ...s etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assem...

Page 4: ...b com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Modbus CAN Datalogger Document code MN67324_ENG Revision 1 200 Page 4 of 44 CONNECTION SCHEME Figure 1a Connecti...

Page 5: ...ces ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Modbus CAN Datalogger Document code MN67324_ENG Revision 1 200 Page 5 of 44 Figure 1b Connection scheme...

Page 6: ...ces ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Modbus CAN Datalogger Document code MN67324_ENG Revision 1 200 Page 6 of 44 Figure 1b Connection scheme...

Page 7: ...324 is a Modbus CAN Datalogger It has the following characteristics Electrical isolation for bus RS232 RS485 CAN Ethernet connection Mountable on Rail DIN Power Supply 8 24V AC or 12 35V DC Temperatur...

Page 8: ...ENG Revision 1 200 Page 8 of 44 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24...

Page 9: ...ice has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Di...

Page 10: ...quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Ethernet communication yellow Blinks when Ethernet request is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in pr...

Page 11: ...State green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Ethernet communication yellow Blinks when Ethernet request is received Blinks quickly Boot state...

Page 12: ...al Modbus CAN Datalogger Document code MN67324_ENG Revision 1 200 Page 12 of 44 RS232 The connection from RS232 socket to a serial port example one from a personal computer must be made with a NULL MO...

Page 13: ...stor it is necessary to put ON dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil s...

Page 14: ...NG Revision 1 200 Page 14 of 44 CAN For terminating the CAN line with a 120 resistor it is necessary to put Dip1 of Dip Switch C at ON position Cable characteristics DC parameter Impedance 70 Ohm m AC...

Page 15: ...g the device and managing the functions The Ethernet connection must be made using Connector2 of HD67324 B2 E xxx xGB with at least a Category 5E cable The maximum length of the cable should not excee...

Page 16: ...use the available software that runs with Windows called SW67324 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last ver...

Page 17: ...0 91 31 User Manual Modbus CAN Datalogger Document code MN67324_ENG Revision 1 200 Page 17 of 44 Figure 3 New Configuration window NEW CONFIGURATION By pressing the New Configuration button it is poss...

Page 18: ...g project by selecting one of the list that appears A configuration can be imported or exported too To clone the configurations of a DataLogger in order to configure another device in the same manner...

Page 19: ...4_ENG Revision 1 200 Page 19 of 44 SAVE CONFIGURATION By pressing the Save Configuration button it is possible to save the project There are two possibilities saving the current configuration by press...

Page 20: ...Dip1 of Dip Switch A in ON position Turn ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Update Device button to start the upload...

Page 21: ...instructions Turn OFF the Device Connect the USB cable from your PC to the device Put Dip1 of Dip Switch A in ON position Select the COM port and press the Open Port button Turn ON the device Check th...

Page 22: ...ble is connected between the PC and the device Try to repeat the operations for the updating Try with another PC Try to restart the PC Check the LAN settings Check the Wi Fi settings If you are using...

Page 23: ...he language of the software CSV OPTIONS In this section is possible to select the options of the CSV file In the field Delimiter the character to split the fields in CSV file is defined If the field S...

Page 24: ...Slave Sniffer or Slave Sniffer Like Master it is the device that makes the requests for read the Coil Status Input Status Holding Register and Input Register The Field Slave ID isn t present with this...

Page 25: ...the Start Stop commands manually by the software If the field Cyclic Memory is checked the DataLogger when the memory is finished restart to save the data from the beginning Otherwise if the field is...

Page 26: ...defined The fields to compile are ID Device ID of the slave device to which the request will be addressed Function type of request used It is possible to define 1 Coil Status 2 Input Status 3 Holding...

Page 27: ...24_ENG Revision 1 200 Page 27 of 44 IDS LIST This section is used only if the Data Logger is set like Sniffer or Slave Sniffer In the left list there are the IDs of the slaves that the Data Logger sni...

Page 28: ...om the beginning Otherwise if the field isn t checked when the memory is full the messages aren t stored and the Led1 blinks very slowly In the field IP ADDRESS the IP address of the DataLogger is def...

Page 29: ...inside the DataLogger It is possible to define different filters in relation of the type of CAN communication used CAN 2 0A and CAN 2 0B CAN 2 0A 11 BITS In the table it is possible to list the COB I...

Page 30: ...sk it is possible to define specific bits of the COB IDs that must have a specific values and others that can change If the Filters CobID is set the fields below have this meaning In the field Filters...

Page 31: ...e 31 of 44 If the Filters Mask is set the fields below have this meaning In the field Insert Mask of CobID the Mask for the COB IDs is defined It is possible to define the bits with fixed values 1 or...

Page 32: ...wnload the stored data of the DataLogger and see them in a grid GET DATA After selecting the correct COM port or the Ethernet settings by pressing the Get Data button the software downloads the data f...

Page 33: ...Data Type type of reply Address Register starting address of the reply Number of Registers number of consecutive registers of the reply Data data read The value is expressed in decimal format For CAN...

Page 34: ...s connected to the PC or the IP Address for the Ethernet version by pressing the Set Custom Date Time it is possible to set the data time that is written in the fields upper by pressing the Set PC Dat...

Page 35: ...nternet Explorer Google Chrome Mozilla Firefox by editing the IP Address programmed inside the Data Logger in the address bar of the browser WELCOME As soon as the connection to the Webserver interfac...

Page 36: ...31 User Manual Modbus CAN Datalogger Document code MN67324_ENG Revision 1 200 Page 36 of 44 When one of the buttons of the Welcome page are pressed it is necessary to do the login using the Admin and...

Page 37: ...5 It has the following structure Time and Date fields Fig 15 Point 1 the time and the date to be written in the Data Logger is defined Set button Fig 15 Point 2 it is possible to write time and date d...

Page 38: ...EVENT button Fig 16 Point 1 it is possible to go to the next logged event PREVIOUS EVENT button Fig 16 Point 2 it is possible to go to the previous logged event FIRST EVENT Fig 16 Point 3 it is possi...

Page 39: ...39 of 44 When the logged events are displayed the events table has these fields NUM fields the number of the event is defined TYPE fields the type of event is defined DATE fields the date when the ev...

Page 40: ...m Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Modbus CAN Datalogger Document code MN67324_ENG Revision 1 200 Page 40 of 44 Figure 17 Mechanical Dimensions for HD6...

Page 41: ...gaBytes BUS connection 485 RS485 232 RS232 PC software connection E Ethernet interface U USB interface Connectors 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M DIN Rail mounting Device Family HD...

Page 42: ...User Manual Modbus CAN Datalogger Document code MN67324_ENG Revision 1 200 Page 42 of 44 ACCESSORIES AC34107 Null Modem Cable Fem Fem DSub 9 Pin 1 5 m AC34114 Null Modem Cable Fem Fem DSub 9 Pin 5 m...

Page 43: ...countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicabl...

Page 44: ...o exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about...