background image

 

 

 

 

e015a DA15K 

e015b DA15KE 

Data Acquisition Systems  

 

User Guide 

SIAP+MICROS

 S.r.l. 

Via del Lavoro,1 

tel +39 0438 491411 

– fax +39 0438 401573 

31020 

– Castello Roganzuolo di San Fior (TV) - ITALY 

email [email protected] 

di San Fior (TV) 

www.siapmicros.com 

Summary of Contents for e015a DA15K

Page 1: ...A15KE Data Acquisition Systems User Guide SIAP MICROS S r l Via del Lavoro 1 tel 39 0438 491411 fax 39 0438 401573 31020 Castello Roganzuolo di San Fior TV ITALY email info siapmicros com di San Fior TV www siapmicros com ...

Page 2: ...sition electronics 7 1 10 Configurable 4 20mA analog input channels 9 1 11 Description of directories and files 9 1 11 1 Drives 10 1 11 2 Files 10 2 Using DA15K data logger 11 2 1 Turning on the DA15K data logger 11 2 2 Tabs of data logging software 12 2 2 1 Measure 12 2 2 2 Parameter 12 2 2 3 Status 12 2 2 4 Setting 13 2 2 5 Log 13 2 3 Procedure for substitution of data logger software 14 2 4 Acq...

Page 3: ...sibility in case of malfunction due to failure to follow instructions tampering uses not described in this manual improper use use by operators not educated Only authorized personnel should have access to the work area for normal use and maintenance The device must be connected to an electrical ground or security through an AC power cord with three wires The cable must be connected to a socket com...

Page 4: ...The manufacturer declines all responsibility in case of failure due to negligence of the instructions tampering uses not described in this manual improper use use by operators not educated Only trained authorized personnel should have access to the work area for normal use and maintenance Safety Regulation The device must be connected to an electrical ground or security The instrument must not ope...

Page 5: ...rument is turned off Avoid turning the power on until you have carefully followed the instructions of installation and start up in this manual 1 5 Safety procedure to turn on DA15K data logger A safety procedure must be followed when turning on a DA15K with an external power supply and a 12V backup battery 1 Connect the battery in the power supply connector at pins BATT GND see chapter 1 9 Descrip...

Page 6: ...to damage it or move it through inexperience or distraction Do not stack other instruments or weights greater than a few pounds Do not stack the device to other devices and however be sure of the strenght and stability of the underlying support 1 8 Maintenance 1 8 1 Device cleaning Please disconnect all connection cables before cleaning the device To clean use a soft dry cloth Never use wet cloths...

Page 7: ...male pin for connecting serial devices such as modems PC sensors and other equipment with RS232 interface One multifunction 28 pin connector for connecting respectively o One multifunction 28 pin connector for connecting respectively o Three pins for serial RS485 in order to connect serial devices such as modems PC sensors and other equipment with RS485 interface o One pin for the watchdog output ...

Page 8: ...onnector for the insertion of a SD memory card industrial rated used by the program for the backup of stored data A switch for the display backlight power off the backlight of the display A button to force quit from the Suspend state of data logger Six Leds representing respectively o ON turn on state o STS flashes if the program DA9000 EXE is running o TX and RX COM3 status of the lines of transm...

Page 9: ...uide v 02 pag 7 Printed in e015 di DA15K Eng docx Siap Micros S r l 1 9 2 Box of data acquisition electronics Dimensions Installation Panel or wall mount with M3 screw Panel or wall mount with low profile DIN rail support ...

Page 10: ...12 bit Frequency Counter logic level Standard 12V sensor power supply DIG IN A DIG IN B Optoisolated digital input DIG OUT Open Drain Digital Output Power Output Frequency Counter Logic level Standard 12V sensor power supply Open drain digital output 12V power output 12V GND with Shutdown EXP RS485 and Digital Output POWER SUPPLY Board power supply RS485 Open drain digital output Solar panel input...

Page 11: ...e solar panel or the 12VDC input if there is no solar energy 1 10 Configurable 4 20mA analog input channels DA15K have four analog input channels that can be configured to acquire a 4 20mA current signal without the need of a precision shunt resistor mounted in series of the current path This shunt with a value of 100Ω is mounted inside the DA15K and convert a 4 20mA current signal in a 0 4 2V vol...

Page 12: ...n interfaces Directory on SD Memory Card on Slot A SD Memory Card on Slot A BackUp contains backup of both stored data and LOG files 1 11 2 Files DA9000 EXE is the data logging software that reads the parameters contained in configuration files with XML extension INI XML and CNF XML Software START EXE is a service software used to manage the possibility to change the configuration during normal pr...

Page 13: ...onds later the V Batt LED start to flash and this shows the battery level related to Voltage detected 1 flash empty 5 flashes full Few seconds later turning on the display bootstrap mask with label SIAP MICROS will appear 30s later Windows CE 6 0 O S will start to run and the applications placed in the directory NandFlash Windows StartUp will start Thus the following mask will appear showed measur...

Page 14: ...asure Parameter Status Settings and LOG 2 2 1 Measure Displays the status of current measurements and any associated alarms 2 2 2 Parameter Displays the parameters in the configuration allowing the modification using the virtual keyboard or via a keyboard with USB interface At the end save the changes using the Save 2 2 3 Status Displays the status of the file archives with the occupied and free s...

Page 15: ... both on Ethernet network and RAS connection IP address and port in the case of a connection to a TUNNEL system Root direction where data file are stored Time span for activation of LIFE signal through WD output Time interval for RTC updating clock The enable for the time synchronization via SNTP protocol 2 2 5 Log This mask displays LOG messages stored in LOG files Main messages are communication...

Page 16: ...d version you must close the software using the X button and enter YES in the next window Connect the data logger to the USB memory equipped with the new software please click the icon my device and select the Hard Disk copy the new program navigate to the directory NandFlash DA9000 and overwrite the file listed After performing the copy start the START EXE software or restart the datalogger ...

Page 17: ...oring autonomy The storing autonomy is determined by the configuration contained in the datalogger Please refer to the DAK software user guide The memory size of the internal disk NandFlash is 215Mbyte for an average autonomy approximately 7000 days about 19 years if data are stored everey 10 minutes 2 7 Substitution of SD memory card SD memory card can be removed in every moment even if the softw...

Page 18: ...nd calibration data made available by the control unit which could be turned on depending of the event The record is composed of three parts named HEAD BODY TAIL Each of these parts of the track is internally divided into comma separated fields character ASCII 44 All the data Instantaneous Data Statistical data Alarm Data Calibration Data etc managed by the system are stored in the internal memory...

Page 19: ...described in the following pages it arose that the European directives applicable to the product in question are as follows Main Guideline Additional or Variation Guideline Title Reference transposition law in Italy 73 23 CEE 93 68 CEE Low Voltage Guideline L 791 77 D Lgs 626 96 D Lgs 277 97 89 336 CEE 93 68 CEE 92 31 CEE Electromagnetic Compatibility Guideline EMC D Lgs 615 96 This product falls ...

Page 20: ...unless they are commercially available 3 Radio equipment used by radio amateurs do not fall within the scope of this Decree unless they are commercially available 4 The disposition of this Decree shall not apply or shall cease to apply to those devices whose protection requirements relating to electromagnetic compatibility are established by rules of implementation of specific directives 5 The equ...

Page 21: ...torage Humidity 90 Professionalism or experience required for operators The staff must be qualified or properly trained and informed about the risks which can be run Determination of the expected life span of the equipment and or some of its components taking into account the intended use The peripheral stations and components used are of robust construction and durable All components are replacea...

Page 22: ...e015x DA15Kx User guide v 02 pag 20 Printed in e015 di DA15K Eng docx Siap Micros S r l 6 Quick Guide 6 1 Set clock without DAK 1 Close DA9000 program pressing X button confirm typing YES and then OK ...

Page 23: ...e015x DA15Kx User guide v 02 pag 21 Printed in e015 di DA15K Eng docx Siap Micros S r l 2 Open folder 3 Open Nand Flash Folder 4 Open DA9000 Folder ...

Page 24: ...e015x DA15Kx User guide v 02 pag 22 Printed in e015 di DA15K Eng docx Siap Micros S r l 5 Start RTC program 6 Set clock and date and press WRITE 7 Switch OFF and switch ON the datalogger ...

Page 25: ...e015x DA15Kx User guide v 02 pag 23 Printed in e015 di DA15K Eng docx Siap Micros S r l 6 2 Changing configuration without DAK 1 Close DA9000 program pressing X botton confirm with YES and OK ...

Page 26: ... Printed in e015 di DA15K Eng docx Siap Micros S r l 2 Open folder 3 Insert the Usb pen drive and wait few seconds for its loading Then open Hard disk folder 4 Select CNF configuration file and if present INI settings file and Copy them ...

Page 27: ...e015x DA15Kx User guide v 02 pag 25 Printed in e015 di DA15K Eng docx Siap Micros S r l 5 Open Nand Flash Folder 6 Open DA9000 Folder ...

Page 28: ...User guide v 02 pag 26 Printed in e015 di DA15K Eng docx Siap Micros S r l 7 Paste new file in the DA9000 folder and confirm update with Yes to All 8 Remove USB pen drive and Switch OFF and switch ON the datalogger ...